Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 9(1): 5456, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30932007

RESUMEN

Exploring new magnetic materials is essential for finding advantageous functional properties such as magnetoresistance, magnetocaloric effect, spintronic functionality, and multiferroicity. Versatile classes of double perovskite compounds have been recently investigated because of intriguing physical properties arising from the proper combination of several magnetic ions. In this study, it is observed that the dominant ferrimagnetic phase is coexisted with a minor multiferroic phase in single-crystalline double-perovskite Er2CoMnO6. The majority portion of the ferrimagnetic order is activated by the long-range order of Er3+ moments below TEr = 10 K in addition to the ferromagnetic order of Co2+ and Mn4+ moments arising at TC = 67 K, characterized by compensated magnetization at TComp = 3.15 K. The inverted magnetic hysteresis loop observed below TComp can be described by an extended Stoner-Wohlfarth model. The additional multiferroic phase is identified by the ferroelectric polarization of ~0.9 µC/m2 at 2 K. The coexisting ferrimagnetic and multiferroic phases appear to be strongly correlated in that metamagnetic and ferroelectric transitions occur simultaneously. The results based on intricate magnetic correlations and phases in Er2CoMnO6 enrich fundamental and applied research on magnetic materials through the scope of distinct magnetic characteristics in double perovskites.

2.
Plant Cell Rep ; 23(5): 291-6, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15365758

RESUMEN

Using cotyledon explants excised from seedlings germinated in vitro, an efficient plant regeneration system via organogenesis was established for bottle gourd (Lagenaria siceraria Standl.). Maximum shoot regeneration was obtained when the proximal parts of cotyledons from 4-day-old seedlings were cultured on MS medium with 3 mg/l BA and 0.5 mg/l AgNO(3) under a 16-h photoperiod. After 3-4 weeks of culture, 21.9-80.7% of explants from the five cultivars regenerated shoots. Adventitious shoots were successfully rooted on a half-strength MS medium with 0.1 mg/l IAA for 2-3 weeks. Flow cytometric analysis revealed that most of the regenerated plants derived from culture on medium with AgNO(3) were diploid.


Asunto(s)
Adenina/análogos & derivados , Cotiledón/crecimiento & desarrollo , Cucurbitaceae/crecimiento & desarrollo , Brotes de la Planta/crecimiento & desarrollo , Adenina/farmacología , Aminobutiratos/farmacología , Compuestos de Bencilo , Cucurbitaceae/genética , Medios de Cultivo/química , Medios de Cultivo/farmacología , Técnicas de Cultivo/métodos , Citometría de Flujo , Genotipo , Ácidos Indolacéticos/farmacología , Cinetina , Ácidos Naftalenoacéticos/farmacología , Reguladores del Crecimiento de las Plantas/farmacología , Ploidias , Purinas , Nitrato de Plata/farmacología
3.
Int J Radiat Oncol Biol Phys ; 48(2): 541-4, 2000 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-10974474

RESUMEN

PURPOSE: A new collimator cone system has been developed at the Samsung Medical Center that overcomes some of the limitations of present commercially supplied collimator cones. The physical properties of the newly developed cone system are described in this report. METHODS AND MATERIALS: The new cones have relatively larger aperture sizes (3.0-7.0 cm in diameter) and are 16 cm in length. Each new cone is fabricated with cerrobend alloy melted and poured into a stainless steel housing that is permanently fixed to a mounting plate. The mounting plate of the new cone is designed to insert into the wedge mount slot of the gantry head. The mechanical accuracy of the central axis of the cone pointing to the isocenter was tested using film, a steel ball positioned at the isocenter by the mechanical isocenter device. For the evaluation of beam flatness and penumbra, off-axis ratios at 5 cm depth were measured by film dosimetry using polystyrene phantom. RESULTS: The average error of the mechanical isocenter was 0.27 mm (+/- 0.16 mm). The beam flatness was excellent in the central region of the beam, and the average penumbra width was 3.35 mm (+/- 0.25 mm). The new cone design has more clearance between the patient's head and the gantry, and can more easily be removed from the gantry head because it slides in and out of the wedge slot. This facilitates changing cone sizes during one treatment session, and makes the process of double exposure port films easier. CONCLUSIONS: A new collimator cone system for stereotactic radiation therapy has been developed. The mechanical accuracy and physical properties are satisfactory for clinical use, and the new design permits a wider range of clinical applications for stereotactic radiation therapy.


Asunto(s)
Radiocirugia/instrumentación , Aleaciones , Diseño de Equipo , Estudios de Evaluación como Asunto , Física Sanitaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...