Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 16(7): 905-8, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11607908

RESUMEN

The articulating surfaces of 6 ultra-high molecular weight polyethylene cups were exposed to curing polymethyl methacrylate (PMMA) bone-cement and examined with scanning electron microscopy and laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). Three of the cups were exposed to blood and bone-cement, and the rest were exposed to bone-cement only. After removal of the bone-cement bulk, PMMA particles were found and identified in all 6 cups. The particles were verified by identifying zirconium with energy-dispersive x-ray fluorescence spectroscopy in 5 cups and with LA-ICPMS in 1 cup. The degree of surface contamination was estimated with LA-ICPMS. The number of zirconium-containing particles detected was on average 10 to 20/mm2. PMMA bone-cement left in polyethylene cups during polymerization can contaminate the articulating surface with adherent PMMA particles.


Asunto(s)
Cementos para Huesos/química , Prótesis de Cadera , Polietilenos , Polimetil Metacrilato/química , Contaminación de Equipos , Espectrometría de Masas , Microscopía Electrónica de Rastreo , Propiedades de Superficie
2.
J Arthroplasty ; 14(2): 138-43, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10065717

RESUMEN

Forty-six patients (48 hips), operated on with cemented total hip arthroplasty (THA) because of arthrosis, were examined radiographically and sonographically at 10-year follow-up. Polyethylene wear of acetabular cups was measured on conventional non-weight-bearing pelvic radiographs, and the volume of polyethylene debris was calculated. Radiographic signs of loosening were identified. The capsular distance (ie, thickness of the synovium or synovial contents) was measured sonographically. We found a significant correlation between increased volumetric wear and increased capsular distance. Hips with radiographically loose acetabular components had significantly greater volumetric wear and capsular distance than those without signs of acetabular loosening. This relationship was not observed in hips with radiographically loose femoral components. In cemented THA, the volume of polyethylene wear debris and the thickness of the synovium and the synovial contents are related. In the event of radiographic loosening of the acetabular component, they are both increased.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Polietilenos , Falla de Prótesis , Sinovitis/etiología , Anciano , Anciano de 80 o más Años , Cementación , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía , Sinovitis/diagnóstico por imagen , Ultrasonografía
3.
Acta Orthop Scand ; 69(2): 133-7, 1998 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9602769

RESUMEN

We analyzed the cumulative revision rate in 1,474 patients (1,660 hips) operated on with a cemented Scan Hip Classic I prosthesis from November 1983 to January 1994 at Lund University Hospital. The revision rate was analyzed for 3 diagnoses--arthrosis, rheumatoid arthritis and complication after a hip fracture--and for 2 head diameters--22 and 32 mm. Until January 1996, 36 hips were revised: 31 because of aseptic loosening, 3 because of dislocation and 2 because of infection. The overall revision rate was 5.6% after 10 years and was similar in arthrosis, rheumatoid arthritis and fracture cases. Due to revisions because of dislocation in the 22 mm group, the total revision rate was lower in the 32 mm group (p = 0.03).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/cirugía , Femenino , Necrosis de la Cabeza Femoral/cirugía , Estudios de Seguimiento , Luxación de la Cadera/cirugía , Fracturas de Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación
4.
Acta Orthop Scand ; 68(3): 231-4, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9246982

RESUMEN

We measured the intracapsular pressure preoperatively in 18 hips (17 patients) before revision of a total hip arthroplasty because of aseptic loosening. Distension of the joint capsule was measured with sonography in 13 cases. In extension, the mean intracapsular pressure was 26 (0-60) mmHg, in extension and inward rotation it was 159 (24-280) mmHg, in extension and outward rotation it was 30 (3-67) mmHg and in 45 degrees of flexion it was 12 (0-28) mmHg. A mean of 6 (0.5-20) mL of joint fluid was aspirated after the pressure measurements. Sonography showed increased joint fluid/synovial edema and/or increased capsular thickness, as compared to 34 unrevised, radiographically not loose prosthetic hips, and that the capsular distension correlated to intracapsular pressure during extension and inward rotation. We conclude that the intracapsular pressure usually is elevated in a hip joint with loose prosthetic components, that the intracapsular pressure varies with the position of the hip and that capsular distension reflects increased intracapsular pressure. The increased and often very high pressure, varying during gait, may pump debris away from the joint along the interfaces and even by itself cause osteolysis and loosening.


Asunto(s)
Articulación de la Cadera/fisiopatología , Prótesis de Cadera/efectos adversos , Cápsula Articular/fisiopatología , Complicaciones Posoperatorias/fisiopatología , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Cápsula Articular/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/cirugía , Presión , Radiografía , Rango del Movimiento Articular , Reoperación , Estudios Retrospectivos , Líquido Sinovial/fisiología , Ultrasonografía
5.
Acta Orthop Scand ; 67(2): 125-7, 1996 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8623564

RESUMEN

We measured radiographic polyethylene wear in patients with Scanhip arthroplasty and no clinical or radiographic signs of loosening. The patients were divided into 2 groups according to head sizes. 32 patients (33 hips) had an implant with a 22 mm and 30 patients (34 hips) with a 32 mm head. They were followed for 7-9 years. The groups were matched for diagnosis, sex, weight, age, and time of follow-up. The mean linear wear with a 22 mm head was 1.1 mm and with a 32 mm head 1.5 mm (p 0.004), which corresponds to a yearly wear rate of 0.15 mm and 0.18 mm, respectively. The mean difference in volumetric wear was greater, 420 mm3, as compared to 1239 mm3.


Asunto(s)
Artritis/cirugía , Prótesis de Cadera , Polietilenos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis
6.
J Bone Joint Surg Br ; 77(6): 862-4, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7593095

RESUMEN

We report the preliminary findings of the use of roentgen stereophotogrammetric analysis to evaluate the early migration of five femoral components after revision for mechanical loosening using impacted cancellous allograft and cement. All hips were examined at one week, four to six months and one year after surgery. All the components subsided by 0.4 to 4.9 mm during the first year. In four hips the prosthetic head was displaced 1.1 to 6.9 mm posteriorly. Fixation of the femoral components was less secure than after primary arthroplasty but the incidence and magnitude of early migration were similar to those after revision with cement alone.


Asunto(s)
Artroplastia/métodos , Cabeza Femoral/trasplante , Migración de Cuerpo Extraño/cirugía , Prótesis de Cadera/efectos adversos , Cadera/cirugía , Anciano , Cementos para Huesos , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/etiología , Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Radiografía , Reoperación , Trasplante Homólogo/métodos
7.
J Arthroplasty ; 10(5): 632-5, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9273374

RESUMEN

Intracapsular hip pressure was measured before surgery in 17 patients (18 hips) with coxarthrosis. The results were correlated to pain as registered on a visual analog scale. With the hip in extension, the pressure was 49.5 mmHg (SD, 40.2); in 45 degrees of flexion, it was 21.3 mmHg (SD, 14.6); in extension and inward rotation, it was 105.7 mmHg (SD, 76.0); and in extension and outward rotation, it was 40.8 mmHg (SD, 32.0). A small amount, 0.7 mL (SD, 1.14), of joint fluid was aspirated following pressure registration. Pressure correlated significantly to pain at night, when starting to walk, and on walking. It is suggested that the increase in intracapsular hip pressure is a cause of pain in coxarthrosis, with subsequent limitation of movement and joint contracture.


Asunto(s)
Articulación de la Cadera/fisiopatología , Osteoartritis de la Cadera/fisiopatología , Dolor/etiología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/complicaciones , Dimensión del Dolor , Presión , Rango del Movimiento Articular
8.
Acta Orthop Scand ; 66(4): 339-42, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7676822

RESUMEN

We evaluated the effect of a prosthetic collar on the proximal femoral bone in 204 hips without any signs of loosening after 5 years. The patients were operated on at 5 centers, using different prosthetic designs, but the same cementing technique. Resorption was more often found in cases with a true and large collar (Lubinus, HD2, Scanhip) than in cases with a flanged or tapered stem (Charnley, Exeter). The resorption was also more pronounced with the former designs. It was concluded that, in spite of theoretical advantages, a large collar is not only unnecessary but may also have negative long-term effects.


Asunto(s)
Enfermedades Óseas Metabólicas/etiología , Resorción Ósea/etiología , Cuello Femoral/fisiopatología , Prótesis de Cadera/efectos adversos , Análisis de Varianza , Cementos para Huesos , Enfermedades Óseas Metabólicas/diagnóstico por imagen , Resorción Ósea/diagnóstico por imagen , Cuello Femoral/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Oportunidad Relativa , Diseño de Prótesis , Radiografía
9.
Acta Orthop Scand ; 66(3): 234-8, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7604704

RESUMEN

We compared the penetration depth into cancellous bone when pressurizing cement at predetermined pressure levels, and at different times after cement mixing, in 21 arthrotic femoral heads during total hip replacement. To determine the influence of circulating blood on cement penetration, cement was injected into holes drilled into the femoral head before and after osteotomy of the femoral neck. The penetration of cement increased on the average 100 percent in the absence of circulation.


Asunto(s)
Cementos para Huesos , Cabeza Femoral/irrigación sanguínea , Prótesis de Cadera , Anciano , Artritis/fisiopatología , Artritis/cirugía , Circulación Sanguínea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión
10.
Acta Orthop Scand ; 65(5): 513-6, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7801752

RESUMEN

We followed 11 patients 3-15 years after a cemented mega total hip replacement for a proximal femoral bone tumor. 7/8 survivors had good function and only occasional pain. 1 hip had been revised because of deep infection and in 1 case the cup had been exchanged because of aseptic loosening. 2 patients had been operated on because of local recurrence of the tumor. At follow-up, 1 patient had radiographic signs of loosening of the stem after 7 years. There was in 8 cases a pronounced athropy of the femoral cortical bone, not correlated to loosening of the stem.


Asunto(s)
Neoplasias Femorales/cirugía , Fémur/patología , Prótesis de Cadera/efectos adversos , Adulto , Anciano , Atrofia/etiología , Cementos para Huesos , Femenino , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Prótesis de Cadera/métodos , Humanos , Masculino , Persona de Mediana Edad , Dolor/etiología , Falla de Prótesis , Radiografía , Reoperación
11.
Scand J Urol Nephrol ; 28(3): 307-9, 1994 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7817178

RESUMEN

A 53-year-old man presented with femoral metastasis from a renal carcinoma. Four months after bone curettage and fixation and nephrectomy, a large recurrence of the metastasis was resected en bloc with the proximal femur and a megaprosthesis inserted. Six years later he is well and physically active.


Asunto(s)
Carcinoma de Células Renales/secundario , Carcinoma de Células Renales/cirugía , Neoplasias Femorales/secundario , Neoplasias Femorales/cirugía , Prótesis de Cadera , Neoplasias Renales/patología , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Femorales/diagnóstico por imagen , Cuello Femoral , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/cirugía , Radiografía , Reoperación , Factores de Tiempo
12.
J Bone Joint Surg Br ; 76(2): 235-9, 1994 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8113283

RESUMEN

We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with radiographic signs of prosthetic loosening had significant reductions in function and quality of life as measured by the NHP questionnaire, but no differences in the mean Charnley hip scores. None of the eight patients had clinical signs of prosthetic loosening sufficient to recommend revision of their THR. The NHP is a relatively low-cost method of providing long-term follow-up of THR.


Asunto(s)
Articulación de la Cadera/fisiología , Prótesis de Cadera , Actividades Cotidianas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Calidad de Vida , Radiografía , Rango del Movimiento Articular , Encuestas y Cuestionarios
13.
Acta Orthop Scand ; 64(3): 257-62, 1993 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8322577

RESUMEN

In 1984 and 1985, 352 hips were randomly assigned to total hip arthroplasty with either low- or high-viscosity cement at 5 Swedish orthopedic departments. Of the 267 hips finally included in the study, 226 were examined clinically and radiographically after 54-77 months. Radiographically, 21 definite stem loosenings and 1 probable stem loosening were observed (10 percent) and 4 additional stems had been exchanged before the 5-year examination. In the survivorship analysis, 261 stem prostheses were included and using this method, 7 percent were radiographically loose after 5 years. There were 4 definitely loose and 8 probably loose acetabular cups. No difference was found between cement of high and low viscosity with regard to prosthetic fixation.


Asunto(s)
Cementos para Huesos , Articulación de la Cadera , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Falla de Prótesis , Radiografía , Distribución Aleatoria
14.
Clin Orthop Relat Res ; (287): 131-4, 1993 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8448931

RESUMEN

Roentgen stereophotogrammetric analysis (RSA) was used to evaluate the migration in 17 cemented acetabular components after revision operations for mechanical loosening. All of the hips were examined four months and one year after surgery; ten of the hips were also examined after two years. In 15 of the 17 components, definite migration (0.5-2.7 mm) was identified, whereas two acetabular components showed no significant migration (< 0.25 mm). In 13 hips, the migration was seen within four months after surgery. There was a tendency for larger migration in revisions for severe bone destruction. These findings indicate that prosthetic fixation in revision operations is relatively poor. In cases with severe bone loss, cement fixations is extremely poor.


Asunto(s)
Acetábulo/diagnóstico por imagen , Migración de Cuerpo Extraño/diagnóstico por imagen , Prótesis de Cadera , Adulto , Anciano , Cementos para Huesos , Resorción Ósea/complicaciones , Femenino , Migración de Cuerpo Extraño/etiología , Humanos , Masculino , Persona de Mediana Edad , Fotogrametría , Falla de Prótesis , Radiografía , Reoperación
15.
J Bone Joint Surg Br ; 74(5): 721-4, 1992 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1527121

RESUMEN

Roentgen stereophotogrammetric analysis was used to measure the migration of 24 cemented femoral components implanted during revision for mechanical loosening. All hips were examined one week, four months and one year after surgery; 14 hips were also examined after two years. Twenty-one components subsided 0.2 to 5.5 mm during the observation period; in 17 of these, subsidence occurred within four months of surgery. In 16 hips the prosthetic head was displaced 0.7 to 11.2 mm posteriorly. The fixation of the femoral components was less secure than after primary arthroplasty, especially in cases of femoral canal enlargement, when a standard-sized rather than a thick-stemmed prosthesis had been used, and in cases of inadequate cement filling.


Asunto(s)
Cementos para Huesos/uso terapéutico , Fémur/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Anciano , Femenino , Estudios de Seguimiento , Prótesis de Cadera/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Fotogrametría , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación/estadística & datos numéricos , Factores de Tiempo
18.
Int Orthop ; 15(4): 305-9, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1809708

RESUMEN

Low viscosity bone cement is expected to give improved long term fixation of prosthetic components by increased intrusion into cancellous bone. Fixation is more difficult to achieve after revision for infection because of the inferior quality of the bone. We have compared the amount of gentamicin released from high viscosity and low viscosity bone cements in 41 patients undergoing total hip replacement. The concentration of gentamicin in serum and the wound secretion, and the amount recovered from the urine, was about three times higher for low viscosity cement. A possible explanation for this is an increase in surface area of the cement body because of improved intrusion of cement into bone. The improved mechanical fixation and the high concentration of gentamicin of the bone cement interface favours the use of low viscosity cement, especially in revision for deep infection.


Asunto(s)
Gentamicinas/farmacocinética , Prótesis de Cadera , Metilmetacrilatos/metabolismo , Anciano , Anciano de 80 o más Años , Femenino , Gentamicinas/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Viscosidad
19.
Acta Orthop Scand ; 61(3): 236-9, 1990 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-2371817

RESUMEN

Two series of patients operated on with total hip replacements for arthrosis are reported. The same prosthesis and operative and cementing techniques were used in both series, except that in Series 2 a centralizing device consisting of four triangular fins passed over the tip was also used to improve the positioning of the femoral stem. It was found that the position of the tip was more central in Series 2. No drawbacks were associated with the use of the device. We concluded that the centralizing device facilitated the positioning of the femoral stem tip.


Asunto(s)
Fémur/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fémur/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera/instrumentación , Prótesis de Cadera/métodos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Radiografía
20.
J Orthop Trauma ; 4(1): 70-4, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2313433

RESUMEN

We report our experience with external fixation in 15 femoral fractures in 14 patients. Follow-up times ranged from 4 to 56 months. Thirteen patients had multiple injuries. All but two fractures healed. In one patient with a supracondylar fracture, a knee arthrodesis had to be performed. One septic osteomyelitis of the femur led to amputation. The range of active knee joint motion was greater than or equal to 90 degree in 13 knees. Only six knees, however, regained a flexion of greater than or equal to 120 degrees. Pin tract infection occurred in one case and resolved uneventfully after revision and systemic antibiotics. External fixation should not be routinely used for fixation of femoral fractures, but may be considered in multiply injured and critically ill patients or in case of extensive soft tissue injury.


Asunto(s)
Fracturas del Fémur/terapia , Dispositivos de Fijación Ortopédica , Adolescente , Adulto , Anciano , Amputación Quirúrgica , Artrodesis , Femenino , Fracturas del Fémur/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Traumatismo Múltiple/complicaciones , Osteomielitis/complicaciones , Radiografía , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA