Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Kaku Igaku ; 38(3): 249-54, 2001 May.
Artículo en Japonés | MEDLINE | ID: mdl-11452492

RESUMEN

Multigated equilibrium radionuclide ventriculography from best septal position (LAO view) was performed in 17 patients with cardiac disease with a single detector Anger-type gamma camera (GCA 602A, Toshiba), then immediately imaged with a solid-state, multi-crystal gamma camera (Digirad 2020tc Imager). Acquisition times were the same of 10 minutes. The solid-state gamma camera uses CsI(Tl) as the scintillation material and a Si photodiode. CsI(Tl) has a higher density and higher atomic number than NaI(Tl), so that its efficiency for detecting gamma rays is higher. To confirm this, total acquisition counts in 17 patients obtained from the 2020tc Imager were significantly higher than those obtained from the Anger-type camera (7847 +/- 2061 K vs. 4427 +/- 1162 K counts, p < 0.0001). In comparing left ventricular ejection fractions obtained from the Anger-type camera and the 2020tc Imager data, an excellent correlation was revealed with a correlation coefficient of 0.97 (p < 0.0001). Again, peak ejection rate and peak filling rate obtained from the 2020tc Imager data correlated well with those obtained from the Anger-type camera data (r = 0.93, p < 0.0001 and r = 0.80, p < 0.001, respectively). These data reveal that the 2020tc Imager has an excellent data collection efficiency and a high reliability in assessment of left ventricular function. Thus, the solid-state gamma camera was thought to be a useful hardware in nuclear cardiology.


Asunto(s)
Imagen de Acumulación Sanguínea de Compuerta , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Pentetato de Tecnecio Tc 99m , Función Ventricular Izquierda , Anciano , Angina de Pecho/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Femenino , Cámaras gamma , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen
2.
J Nucl Cardiol ; 8(2): 152-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11295692

RESUMEN

BACKGROUND: Technetium-labeled myocardial perfusion tracers allow simultaneous assessment of myocardial perfusion and left ventricular function by electrocardiography (ECG)-gated myocardial single photon emission computed tomography (SPECT). The purpose of this study was to evaluate left ventricular performance during dobutamine stress by means of ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS AND RESULTS: After administration of Tc-99m sestamibi or tetrofosmin (600-740 MBq), 67 patients with ischemic heart disease, including 35 with prior myocardial infarction, were examined by ECG-gated myocardial perfusion SPECT at rest and during dobutamine stress (at dosages of 4, 8, 12, 16, and 20 microg/kg/min, with increments every 8 minutes). The ECG-gated data collection time was 5 minutes for each dobutamine dosage. After acquisition of gated SPECT data at the highest dose, thallium 201 chloride (111 MBq) was injected, and dual-isotope SPECT was also performed to assess the myocardial ischemia. In 32 patients without prior myocardial infarction, the sensitivity of individual stenosed-vessel detection with dual-isotope perfusion SPECT, with wall motion abnormality obtained from gated SPECT, and with the combined method was 55.9%, 52.9%, and 73.5%, respectively, based on coronary angiography. ECG-gated SPECT during dobutamine infusion revealed regional wall motion abnormalities (worsening or biphasic response) in 19 (57.6%) of 33 infarcted areas with culprit coronary arterial stenosis. The prevalence of reversible perfusion defects on dual-isotope SPECT was higher in segments with wall motion abnormalities than in segments with normal wall motion response (89.5% vs 42.9%, P <.02). CONCLUSIONS: Myocardial perfusion and left ventricular function during dobutamine infusion were analyzed in a single examination by means of the combined method. This procedure has the potential to provide comprehensive information with which to evaluate patients with ischemic heart disease.


Asunto(s)
Circulación Coronaria , Dobutamina , Electrocardiografía , Corazón/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Compuestos Organofosforados , Compuestos de Organotecnecio , Radiofármacos , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único , Función Ventricular Izquierda , Presión Sanguínea/efectos de los fármacos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Isquemia Miocárdica/fisiopatología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...