Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
JACC Cardiovasc Interv ; 17(15): 1825-1836, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39142758

RESUMEN

BACKGROUND: In patients with in-stent restenosis (ISR) bioresorbable vascular scaffolds (BVS) provide similar results to drug-coated balloons (DCBs) but are inferior to drug-eluting stents (DES) at 1 year. However, the long-term efficacy of BVS in these patients remains unknown. OBJECTIVES: This study sought to assess the long-term safety and efficacy of BVS in patients with ISR. METHODS: RIBS VI (Restenosis Intrastent: Bioresorbable Vascular Scaffolds Treatment; NCT02672878) and RIBS VI Scoring (Restenosis Intrastent: Bioresorbable Vascular Scaffolds Treatment With Scoring Balloon; NTC03069066) are prospective multicenter studies designed to evaluate the results of BVS in patients with ISR (N = 220). The inclusion and exclusion criteria were identical to those used in the RIBS IV (ISR of DES) (Restenosis Intra-stent of Drug-eluting Stents: Drug-eluting Balloon vs Everolimus-eluting Stent; NCT01239940) and RIBS V (ISR of bare-metal stents) (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs Everolimus-eluting Stent; NCT01239953) randomized trials (including 249 ISR patients treated with DCBs and 249 ISR patients treated with DES). A prespecified comparison of the long-term results obtained with these treatment modalities (ie, DES, DCBs, and BVS) was performed. RESULTS: Clinical follow-up at 3 years was obtained in all (100%) 718 patients. The 3-year target lesion revascularization rate after BVS was 14.1% (vs 12.9% after DCBs [not significant], and 5.2% after DES [HR: 2.80; 95% CI: 1.47-5.36; P = 0.001]). In a landmark analysis (>1 year), the target lesion revascularization rate after BVS was higher than after DES (adjusted HR: 3.41; 95% CI: 1.15-10.08) and DCBs (adjusted HR: 3.33; 95% CI: 1.14-9.70). Very late vessel thrombosis was also more frequent with BVS (BVS: 1.8%, DCBs: 0.4%, DES: 0%; P = 0.03). CONCLUSIONS: In patients with ISR, late clinical results of DES are superior to those obtained with DCBs and BVS. Beyond the first year, DCBs are safer and more effective than BVS.


Asunto(s)
Implantes Absorbibles , Reestenosis Coronaria , Diseño de Prótesis , Humanos , Factores de Tiempo , Masculino , Resultado del Tratamiento , Femenino , Estudios Prospectivos , Reestenosis Coronaria/etiología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/terapia , Persona de Mediana Edad , Anciano , Factores de Riesgo , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/efectos adversos , Stents , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Materiales Biocompatibles Revestidos , Stents Liberadores de Fármacos , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Artículo en Inglés, Español | MEDLINE | ID: mdl-39187234

RESUMEN

INTRODUCTION AND OBJECTIVES: Impact of gender on long-term outcomes after transcatheter aortic valve implantation (TAVI) remains uncertain. We aimed to investigate gender-specific differences in TAVI and its impact on outcomes. METHODS: This analysis used data from the prospective Spanish TAVI registry, which included consecutive TAVI patients treated in 46 Spanish centers from 2009 to 2021. The primary endpoint was all-cause mortality at 12 months. Secondary endpoints included in-hospital and 30-day mortality and TAVI-related complications. Adjusted logistic and Cox regression analyses were performed. RESULTS: The study included 12 253 consecutive TAVI patients with a mean age of 81.2±6.4 years. Women (53.9%) were older, and had a higher STS-PROM score (7.0±7.0 vs 6.2±6.7; P < .001) than men. Overall, the TAVI-related complication rate was similar between women and men, with specific gender-related complications. While women more frequently developed in-hospital vascular complications (13.6% vs 9.8%; P <.001) and cardiac tamponade (1.5% vs 0.6%; P=.009), men showed a higher incidence of permanent pacemaker implantation (14.5% vs 17.4%; P=.009). There was no difference in all-cause mortality either in hospital (3.6% vs 3.6%, adjusted OR, 1.01; 95%CI, 0.83-1.23; P=.902), at 30 days (4.2% vs 4.2%, adjusted OR, 0.90; 95%CI, 0.65-1.25; P=.564) or at 1 year (11% vs 13%, adjusted HR, 0.94; 95%CI, 0.80-1.11; P=.60). CONCLUSIONS: Women treated with TAVI are older and have more comorbidities than men, leading to distinct complications between genders. Nevertheless, all-cause mortality in the short-term and at 1-year was similar between men and women.

3.
Rev Esp Cardiol (Engl Ed) ; 76(12): 1021-1031, 2023 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37863184

RESUMEN

INTRODUCTION AND OBJECTIVES: This article presents the annual activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) for the year 2022. METHODS: All Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company in collaboration with the members of the board of the ACI-SEC. RESULTS: A total of 111 centers participated. The number of diagnostic studies increased by 4.8% compared with 2021, while that of percutaneous coronary interventions (PCI) remained stable. PCIs on the left main coronary artery increased by 22%. The radial approach continued to be preferred for PCI (94.9%). There was an upsurge in the use of drug-eluting balloons, as well as in intracoronary imaging techniques, which were used in 14.7% of PCIs. The use of pressure wires also increased (6.3% vs 2021) as did plaque modification techniques. Primary PCI continued to grow and was the most frequent treatment (97%) in ST-segment elevation myocardial infarction. Most noncoronary procedures maintained their upward trend, particularly percutaneous aortic valve implantation, atrial appendage closure, mitral/tricuspid edge-to-edge therapy, renal denervation, and percutaneous treatment of pulmonary arterial disease. CONCLUSIONS: The Spanish cardiac catheterization and coronary intervention registry for 2022 reveals a rise in the complexity of coronary disease, along with a notable growth in procedures for valvular and nonvalvular structural heart disease.


Asunto(s)
Cardiología , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Cateterismo Cardíaco , Sistema de Registros
4.
Diabetes Ther ; 14(11): 1853-1865, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37665429

RESUMEN

INTRODUCTION: Sodium-glucose type 2 cotransporter inhibitors (SGLT2-I) have shown solid benefits in reducing cardiovascular mortality and admissions for heart failure in patients with type 2 diabetes mellitus (T2DM) and cardiovascular disease. However, no specific studies exist in patients with high-risk coronary artery disease (CAD). METHODS: Single-center, retrospective, observational study including patients with T2DM and a new diagnosis of extensive CAD (defined as left main disease or three main coronary vessel disease). Patients were recruited from 2015 until 2020, with a follow-up of at least 12 months. The primary outcome was to compare all-cause mortality in patients treated with or without SGLT2-I at discharge and adjusted by inverse probability of treatment weighting (IPTW) propensity score. RESULTS: A total of 420 patients were included: 104 (24.7%) were treated with SGLT2-I and 316 (75.3%) were not (non-SGLT2-I group). The presentation was acute coronary syndrome in 44.3%. The mean age was 71.2 ± 10.5 years. The mean left ventricular ejection fraction was 51.5 ± 12.5%, and the mean estimated glomerular filtration rate was 73.9 ± 22 ml/min. After a mean follow-up of 3 ± 1.6 years, all-cause mortality was 16.4%, and cardiovascular mortality was 9.5%. After IPTW, the risk of all-cause death was lower in the SGLT2-I group with a hazard ratio of 0.32 (95% confidence interval 0.12-0.81), p = 0.016. With regard to secondary outcomes, patients in the SGLT2-I group were associated with less renal function deterioration but an increase in unplanned revascularizations. CONCLUSIONS: In patients with T2DM and extensive CAD, treatment with SGLT2-I after discharge was associated with a reduced risk of all-cause death.

5.
Coron Artery Dis ; 33(8): 609-617, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36238983

RESUMEN

BACKGROUND: Treatment of in-stent restenosis (ISR) remains a significant challenge. Current options include repeat stenting or drug-coated balloons. However, there is a paucity of data regarding vascular healing after these strategies. We, aimed to compare optical coherence tomography (OCT)-based vessel healing after treatment with paclitaxel-coated balloons (PCB) or everolimus-eluting stents (EES). METHODS: An OCT substudy (baseline and 6-9 months) of patients from RIBS IV and RIBS V, two prospective multicenter, randomized controlled clinical trials comparing PCB vs. EES in patients with ISR was performed. RESULTS: Sixty-four patients were included (30 PCB and 34 EES). There were no differences in the baseline or angiographic characteristics between groups. Both groups had the same proportion of drug-eluting and bare-metal stent (BMS) ISR. Baseline OCT analysis did not show differences in the qualitative characteristics of the ISR nor the restenotic tissue burden. Follow-up OCT showed a larger mean lumen area in the EES group (6.03 ± 1.5 vs. 5.24 ± 1.3 mm 2 ; P = 0.043) but no difference in angiographic restenosis ( P = 0.66). Percentage tissue coverage was higher with PCB vs. EES (26 ± 13 vs. 19 ± 11%; P = 0.031). EES-treated ISR more frequently had uncovered struts at follow-up [21 (72%) vs. 12 (44%); P = 0.034]. Tissue covering struts more frequently had a high backscatter structure after PCB [21 (78%) vs. 16 (55%); P = 0.07]. CONCLUSIONS: Compared with EES, ISR treated with PCB demonstrated more strut coverage with mainly high backscattering tissue. Larger OCT-defined neointimal proliferation in PCB-treated ISR did not translate into higher angiographic restenosis rates.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Humanos , Everolimus , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Paclitaxel , Tomografía de Coherencia Óptica , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Estudios Prospectivos , Angiografía Coronaria , Metales , Resultado del Tratamiento , Stents , Constricción Patológica/tratamiento farmacológico
6.
Cardiol J ; 29(4): 553-562, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33843040

RESUMEN

BACKGROUND: The safety of revascularization deferral according to pressure wire examination in patients with chronic kidney disease (CKD) has not been fully established. METHODS: From a retrospective cohort of 439 patients in whom revascularization was deferred after physiological assessment, we examined the incidence of patient-oriented composite endpoint (POCE: all-cause death, myocardial infarction [MI] and unplanned revascularization) in patients with CKD (estimated glomerular filtration rate [eGFR] < 60 mL/min/1.73 m²) and without it. RESULTS: At 4 years of follow-up, the primary endpoint was met by 25.0% of patients with CKD and by 14.4% of patients without CKD (hazard ratio [HR] 1.56, 95% confidence interval [CI] 0.96-2.53, p = 0.071). The incidence of POCE was even higher in patients with an eGFR < 30 mL/min/1.73 m²: 43.8% (HR 3.10, 95% CI 1.08-8.92, p = 0.036). However, no differences were observed in the incidence of MI (4.2% vs. 4.4% in non-CKD), target vessel revascularization (5.8% vs. 5.9%), and target vessel MI (0.8% vs. 4.6%). CONCLUSIONS: Patients with CKD in whom pressure-wire evaluation led to deferral of coronary revascularization develop more POCE in the long term, compared to patients with normal renal function. However, the increase in POCE in patients with CKD was seldom related to deferred vessels, thus suggesting an epiphenomenon of an intrinsically higher cardiovascular risk of CKD patients.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Insuficiencia Renal Crónica , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Infarto del Miocardio/etiología , Revascularización Miocárdica/efectos adversos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
7.
Rev. esp. cardiol. (Ed. impr.) ; 74(5): 427-435, may. 2021. tab, graf, ilus
Artículo en Inglés, Español | IBECS | ID: ibc-232555

RESUMEN

Introducción y objetivos La neoateroesclerosis es una de las causas de la reestenosis en el stent (RS). Nuestro objetivo es evaluar la influencia de la neoateroesclerosis en el pronóstico y la respuesta al tratamiento de los pacientes con RS. Métodos Se trata de un análisis conjunto de los subestudios de tomografía de coherencia óptica (OCT) de los RIBS IV y V, 2 ensayos clínicos aleatorizados y multicéntricos que comparan el tratamiento con un balón recubierto con paclitaxel frente al stent liberador de everolimus en pacientes con RS. La evaluación con OCT se realizó basalmente y a los 6-9 meses. La neoateroesclerosis se definió en la OCT basal como una neoíntima con contenido calcificado o lipídico. Se evaluaron los resultados angiográficos y por OCT a los 6-9 meses y la aparición de eventos adversos cardiovasculares mayores a los 3 años de seguimiento en pacientes con y sin neoateroesclerosis tratados con balón recubierto con paclitaxel o stent liberador de everolimus. Resultados Se estudió mediante OCT a 64 pacientes en el momento del procedimiento. Se documentó neoateroesclerosis en 23 lesiones (36%). El seguimiento angiográfico a los 6-9 meses no mostró diferencias entre los pacientes con y sin neoateroesclerosis en reestenosis (5 [24%] frente a 6 [15%]; p=0,49), diámetro luminal mínimo (1,79±0,7 frente a 1,94±0,6 mm; p=0,41) o pérdida tardía (0,33±0,7 frente a 0,15±0,5; p=0,34). El seguimiento con OCT confirmó la ausencia de diferencias en los parámetros cuantitativos y las características del tejido de recubrimiento entre los 2 grupos. A los 3 años de seguimiento, la incidencia de eventos fue de 3 (13%) frente a 5 (12%) en los grupos con y sin neoateroesclerosis respectivamente (HR=0,94; IC95%, 0,22-3,93; p=0,93). Conclusiones En este estudio con una pequeña muestra de pacientes aleatorizados a tratamiento con balón recubierto con paclitaxel o stent liberador de everolimus por RS, ... (AU)


Introduction and objectives Neoatherosclerosis is one of the causes of in-stent restenosis (ISR). Our objective was to evaluate the influence of neoatherosclerosis on prognosis and treatment response in patients with ISR. Methods This is a pooled analysis of the optical coherence tomography (OCT)-substudies of 2 multicenter, randomized clinical trials, RIBS IV and V, comparing treatment with paclitaxel-coated balloon vs everolimus-eluting stent in patients with ISR. OCT evaluation was performed at baseline and at 6 to 9 months. Neoatherosclerosis was defined in baseline OCT as neointima with calcified or lipid content. We evaluated the angiographic and OCT results at 6 to 9 months and the occurrence of major adverse cardiovascular events at 3 years of follow-up in patients with and without neoatherosclerosis treated with paclitaxel-coated balloon or everolimus-eluting stents. Results Sixty-four patients underwent OCT at the time of the index procedure. Neoatherosclerosis was documented in 23 (36%) lesions. Angiographic follow-up at 6 to 9 months showed no differences in restenosis [5 (24%) vs 6 (15%) P=.49], minimum lumen diameter (1.79±0.7 vs 1.94±0.6mm; P=.41) or late loss (0.33±0.7 vs 0.15±0.5; P=.34) in patients with and without neoatherosclerosis, respectively. Follow-up OCT confirmed the absence of differences in quantitative parameters and the characteristics of tissue coverage between the 2 groups. At 3 years of follow-up, the major adverse cardiovascular events rate was 3 (13%) vs 5 (12%) in the neoatherosclerosis and nonneoatherosclerosis groups (HR, 0.94; 95%CI, 0.22-3.93; P=.93). Conclusions In this limited study population, OCT-defined neoatherosclerosis did not seem to influence acute and long-term outcomes in patients randomized to paclitaxel-coated balloon or everolimus-eluting stents for ISR. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Reestenosis Coronaria/complicaciones , Reestenosis Coronaria/terapia , Aterosclerosis , Stents
8.
Int Heart J ; 62(2): 274-281, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33731529

RESUMEN

The COVID-19 pandemic severely disrupted cardiovascular care during the spring of 2020 in Europe. Our study analyzed the clinical profile, COVID-19 impact, and 30-day prognosis of invasively managed patients with acute coronary syndrome (ACS) compared to a historical cohort.All invasively managed ACS patients from March 1st to April 30th, 2020 were compared to a cohort from the same timeframe of 2019 (n = 316). COVID-19 confirmed cases were defined by a positive SARS-CoV-2 polymerase chain reaction (PCR) test (CoV+). The primary outcome was all-cause 30-day mortality and multivariable predictors of this outcome.A 40.4% reduction in ACS patients was noted (198 cases in 2019 to 118 in 2020), and 11% of 2020 ACS patients were CoV+. Baseline characteristics were similar between groups. There were significantly more in-hospital patients with ACS (15.3% versus 6.1%, P = 0.007), and fewer patients were found to have a culprit lesion (58.5% versus 74.2%, P = 0.004) in 2020 compared to 2019. Thirty-day mortality in 2020 (7%) was not different from that in 2019 (4.2%), P = 0.294, but it was significantly higher in CoV+ patients (23.1%) compared to that in negative SARS-CoV-2 PCR test (CoV-) patients (5%), P = 0.047, in the 2020 group. In the multivariate analysis, CoV+ was an independent mortality predictor (OR = 9.8, 95% CI = 1.48-64.78), along with the left ventricular ejection fraction (LVEF) (OR = 0.91, 95% CI = 0.86-0.97), P = 0.0006.This study found increased 30-day mortality of invasively managed CoV+ ACS patients compared to that of CoV- patients during the 2020 COVID-19 spring outbreak. In the multivariable analysis, a SARS-CoV-2 positive test was independently associated with 30-day mortality. Further investigations of the underlying physiopathological relations between COVID-19 and ACS are warranted.


Asunto(s)
Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , COVID-19/epidemiología , Brotes de Enfermedades , Síndrome Coronario Agudo/diagnóstico , Anciano , COVID-19/diagnóstico , COVID-19/terapia , Estudios de Cohortes , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Intervención Coronaria Percutánea , Pronóstico , España , Volumen Sistólico , Tasa de Supervivencia
9.
EuroIntervention ; 17(5): e388-e395, 2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32894230

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) and drug-eluting stents (DES) represent the currently recommended treatments for in-stent restenosis (ISR). Optical coherence tomography (OCT) allows detailed neointimal characterisation which can guide treatment strategies. AIMS: The aims of this study were first, to assess the relation between neointimal pattern and clinical outcomes following in-stent restenosis (ISR) treatment, and second, to explore a potential interaction between neointimal pattern and treatment modality relative to clinical outcomes. METHODS: Patients undergoing OCT-guided treatment (DCB or DES) of ISR in three European centres were included. Based on the median of distribution of non-homogeneous neointima quadrants, patients were categorised into low and high inhomogeneity groups. RESULTS: A total of 197 patients (low inhomogeneity=100 and high inhomogeneity=97) were included. There were no significant differences in terms of major adverse cardiac events (MACE) (p=0.939) or target lesion revascularisation (TLR) (p=0.732) between the two groups. The exploratory analysis showed a significant interaction between neointimal pattern and treatment modality regarding MACE (pint=0.006) and TLR (pint=0.022). DES showed a significant advantage over DCB in the high (MACE: HR 0.26 [0.10-0.65], p=0.004; TLR: HR 0.28 [0.11-0.69], p=0.006), but not in the low inhomogeneity group (MACE: p=0.917; TLR: p=0.797). CONCLUSIONS: In patients with ISR treated with DCB or DES, there were no significant differences in terms of MACE or TLR between the low and high inhomogeneity groups. A significant interaction was observed between treatment modality and neointimal pattern with an advantage of DES over DCB in the high and no difference in the low inhomogeneity group. This warrants confirmation from prospective dedicated studies.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Humanos , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
10.
Rev Esp Cardiol (Engl Ed) ; 74(5): 427-435, 2021 May.
Artículo en Inglés, Español | MEDLINE | ID: mdl-32439297

RESUMEN

INTRODUCTION AND OBJECTIVES: Neoatherosclerosis is one of the causes of in-stent restenosis (ISR). Our objective was to evaluate the influence of neoatherosclerosis on prognosis and treatment response in patients with ISR. METHODS: This is a pooled analysis of the optical coherence tomography (OCT)-substudies of 2 multicenter, randomized clinical trials, RIBS IV and V, comparing treatment with paclitaxel-coated balloon vs everolimus-eluting stent in patients with ISR. OCT evaluation was performed at baseline and at 6 to 9 months. Neoatherosclerosis was defined in baseline OCT as neointima with calcified or lipid content. We evaluated the angiographic and OCT results at 6 to 9 months and the occurrence of major adverse cardiovascular events at 3 years of follow-up in patients with and without neoatherosclerosis treated with paclitaxel-coated balloon or everolimus-eluting stents. RESULTS: Sixty-four patients underwent OCT at the time of the index procedure. Neoatherosclerosis was documented in 23 (36%) lesions. Angiographic follow-up at 6 to 9 months showed no differences in restenosis [5 (24%) vs 6 (15%) P=.49], minimum lumen diameter (1.79±0.7 vs 1.94±0.6mm; P=.41) or late loss (0.33±0.7 vs 0.15±0.5; P=.34) in patients with and without neoatherosclerosis, respectively. Follow-up OCT confirmed the absence of differences in quantitative parameters and the characteristics of tissue coverage between the 2 groups. At 3 years of follow-up, the major adverse cardiovascular events rate was 3 (13%) vs 5 (12%) in the neoatherosclerosis and nonneoatherosclerosis groups (HR, 0.94; 95%CI, 0.22-3.93; P=.93). CONCLUSIONS: In this limited study population, OCT-defined neoatherosclerosis did not seem to influence acute and long-term outcomes in patients randomized to paclitaxel-coated balloon or everolimus-eluting stents for ISR.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico , Humanos , Paclitaxel , Pronóstico , Tomografía de Coherencia Óptica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA