Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomed Chromatogr ; 34(1): e4742, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31749152

RESUMEN

Quantitation of drugs used for the treatment of chronic lymphocytic leukemia in various biological matrices during both pre-clinical and clinical developments is very important, often in routine therapeutic drug monitoring. The first developed methods for quantitation were traditionally done on LC in combination with either UV or fluorescence detection. However, the emergence of LC with mass spectrometry in tandem in early 1990s has revolutionized the quantitation as it has provided better sensitivity and selectivity within a shorter run time; therefore it has become the choice of method for the analysis of various drugs. In this article, an overview of various bioanalytical methods (HPLC or LC-MS/MS) for the quantification of drugs for the treatment of chronic lymphocytic leukemia, along with applicability of these methods, is given.


Asunto(s)
Antineoplásicos , Cromatografía Liquida , Leucemia Linfocítica Crónica de Células B/tratamiento farmacológico , Antineoplásicos/análisis , Antineoplásicos/farmacocinética , Antineoplásicos/uso terapéutico , Monitoreo de Drogas , Humanos , Espectrometría de Masas en Tándem
2.
Biomed Chromatogr ; 31(4)2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27632936

RESUMEN

A highly sensitive, specific and enantioselective assay has been validated for the quantitation of OTX015 enantiomers [(+)-OTX015 and (-)-OTX015] in mice plasma on LC-MS/MS-electrospray ionization as per regulatory guidelines. Protein precipitation was used to extract (±)-OTX015 enantiomers and internal standard (IS) from mice plasma. The active [(-)-OTX015] and inactive [(+)-OTX015] enantiomers were resolved on a Chiralpak-IA column using an isocratic mobile phase (0.2% ammonia/acetonitrile 20 : 80, v/v) at a flow rate of 1.2 mL/min. The total run time was 6.0 min. (+)-OTX015, (-)-OTX015 and IS eluted at 3.34, 4.08 and 4.77 min, respectively. The MS/MS ion transitions monitored were m/z 492 → 383 for OTX015 and m/z 457 → 401 for IS. The standard curves for OTX015 enantiomers were linear (r2 > 0.998) in the concentration range 1.03-1030 ng/mL. The inter- and intraday precisions were in the range 2.20-13.3 and 8.03-12.1% and 3.80-14.4 and 8.97-13.6% for (+)-OTX015 and (-)-OTX015, respectively. Both the enantiomers were found to be stable in a battery of stability studies. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (-)-OTX015 and unequivocally demonstrated that (-)-OTX015 does not undergo chiral inversion to its antipode in vivo in mice.


Asunto(s)
Acetanilidas/sangre , Acetanilidas/química , Cromatografía Liquida/métodos , Compuestos Heterocíclicos con 3 Anillos/sangre , Compuestos Heterocíclicos con 3 Anillos/química , Espectrometría de Masas en Tándem/métodos , Acetanilidas/administración & dosificación , Acetanilidas/farmacocinética , Administración Oral , Animales , Calibración , Estabilidad de Medicamentos , Compuestos Heterocíclicos con 3 Anillos/administración & dosificación , Compuestos Heterocíclicos con 3 Anillos/farmacocinética , Masculino , Ratones Endogámicos BALB C , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray , Estereoisomerismo
3.
Biomed Chromatogr ; 29(2): 254-60, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24944160

RESUMEN

A rapid and highly sensitive assay method has been developed and validated for the estimation of bicalutamide (BCL) on mouse dried blood spots (DBS) using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the negative-ion mode. The assay procedure involves a simple liquid extraction of BCL and tolbutamide (internal standard, IS) from mouse blood DBS cards using tert-butyl methyl ether. Chromatographic separation was achieved with 5 mm ammonium acetate (pH 6.5)-acetonitrile (35:65, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 428.80 → 254.70 for BCL and 269.00 → 169.60 for IS. Method validation was performed as per regulatory guidelines. A linear response function was observed from 0.92 to 1911 ng/mL for BCL in mouse blood. The intra- and inter-day precisions were in the ranges of 1.86-12.5 and 3.19-10.8%, respectively. This novel DBS method has been applied to a pharmacokinetic study in mice.


Asunto(s)
Anilidas/análisis , Cromatografía Liquida/métodos , Nitrilos/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Compuestos de Tosilo/análisis , Animales , Ratones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...