Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arthroscopy ; 13(6): 720-4, 1997 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9442325

RESUMEN

Previous experimental studies of failure of rotator cuff repair have involved single pull to ultimate load. Such an experimental design does not represent the cyclic loading conditions experienced in vivo. We created 1 x 2 cm rotator cuff defects in 16 cadaver shoulders, repaired each defect with three Mitek-RC suture anchors (Mitek Surgical Products, Inc, Westwood, MA) using simple sutures of No. 2 Ethibond, and cyclically loaded the repairs by a servohydraulic materials test system actuator at physiological rates and loads (rate of 33 mm/s, load 180 N). A progressive gap was noted in each specimen, for a 100% rate of failure of the repairs. The central suture always failed first and by the largest magnitude, confirming tension overload centrally. One specimen exhibited combined bone and tendon failure, but the other 15 specimens failed through the tendon. Overall, the repairs failed to 5 mm and 10 mm at an average of 61 cycles and 285 cycles, respectively. Half the specimens were less than 45 years of age and had a 5-mm and 10-mm failure at an average of 107 and 478 cycles, respectively. The other half were over 45 years of age and failed to 5 mm and 10 mm at an average of 17 and 91 cycles, respectively, indicating more rapid failure of the rotator cuff tendons in the older group, and this was statistically significant (P < or = .02). Comparison of suture anchor fixation in this study with transosseous bone tunnel fixation in a previous cyclic loading study at this institution indicates that bone fixation by suture anchors is significantly less prone to failure than bone fixation through bone tunnels (P = .0008). Changing the bone fixation from bone tunnels to suture anchors effectively transferred the weak link from bone to tendon.


Asunto(s)
Manguito de los Rotadores/cirugía , Técnicas de Sutura , Adolescente , Adulto , Factores de Edad , Análisis de Varianza , Cadáver , Falla de Equipo , Humanos , Húmero/fisiopatología , Húmero/cirugía , Ensayo de Materiales/instrumentación , Persona de Mediana Edad , Tereftalatos Polietilenos/química , Manguito de los Rotadores/fisiopatología , Estrés Mecánico , Técnicas de Sutura/efectos adversos , Técnicas de Sutura/instrumentación , Suturas , Resistencia a la Tracción , Factores de Tiempo
2.
Bol Asoc Med P R ; 84(4-5): 132-3, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1295501

RESUMEN

Jehovah's Witnesses (J.W.) can undergo successful cardiac operations. We have operated five J.W. patients. Of these patients, two had coronary artery bypass surgery and three had correction of congenital anomalies. These included an atrial septal defect with infundibular pulmonic stenosis, a tetralogy of Fallot and a patient with a ventricular septal defect. Our treatment protocol includes a meticulous surgery, the use of early heparinization to collect all shed blood into the pump oxygenator, observation in the operating room for early exploration if the patient bleeds and administration of iron preparations. Recombinant human erythropoietin, although available and in our treatment protocol, has not been used yet. All patients survived the operation and left the hospital with an excellent hemoglobin and hematocrit. The length of stay varied from 7 to 15 days.


Asunto(s)
Instituciones Cardiológicas , Procedimientos Quirúrgicos Cardíacos , Cristianismo , Adolescente , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Cuidados Intraoperatorios/métodos , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Cuidados Preoperatorios/métodos , Puerto Rico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...