RESUMEN
A total of 12 patients with malignant localized renal or ureteral neoplasms underwent multi-slice computed tomography. Imaging data were sent to the dedicated workstation to create volume rendering and virtual laparoscopic images of the kidney which was displaced ventrally with retroperitoneal balloon. These findings were compared with video images obtained during retroperitoneal laparoscopic nephrectomy. The kidney displacement simulator depicted all renal arteries (100% sensitivity) and 13 of 14 renal veins (93% sensitivity). Hilar anatomy, including the tumor, major vessels and their relationships were visualized as in the actual laparoscopic views. The desired portions of major vessels as well as the left adrenal and gonadal veins visualized with this system completely corresponded with the actual laparoscopic images during surgery. The kidney displacement simulator is useful to foresee desired portions of major vessels and branched small vessels such as the adrenal or gonadal veins in advance of surgery. It is thus able to guide surgeons and reduce operative risks and possible complications.
Asunto(s)
Imagenología Tridimensional , Riñón/anatomía & histología , Laparoscopía , Nefrectomía , Tomografía Computarizada Espiral , Cateterismo , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Espacio Retroperitoneal , Neoplasias Ureterales/diagnóstico por imagen , Neoplasias Ureterales/cirugíaRESUMEN
A lump is the first symptom in over 80 percent of all patients with cancer of the breast. Consequently, the finding of any lump in the breast is a highly significant sign and warrants a thorough investigation. The present study was undertaken to study the predictive value of ultrasonography in the diagnosis of palpable breast lumps. Fifty-two female patients with palpable breast lumps that were unilateral underwent ultrasonography of the breast. Thirty-six of these patients who had solitary, unilateral, solid lumps were followed up with FNAC/biopsy/mammography and the findings were compared. The mean age group was seen to be 41 years. The youngest patient was 17 years old and the oldest was 80 years. The validity of USG in the diagnosis of palpable breast lumps was calculated. A sensitivity value of 95%, specificity of 94.10%, positive and negative predictive values of 95.50% and 93.75% were noted and were comparable to other similar studies. The sensitivity, specificity, positive and negative predictive values were statistically significant (p=0.0000006) and were comparable to the values obtained by different studies conducted elsewhere. Among the multiple USG parameters, shape, margins, vascularity, surrounding tissue character, sound transmission through the lump were more significant in the diagnosis of benign vs. malignant lumps. Echogenicity and echotexture were of less significance.