Resultados 1 - 18 de 18
Filtrar
1.
Phys Eng Sci Med ; 47(3): 1167-1176, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38807011

RESUMEN

This article documents the work conducted in implementing the IAEA non-agreement TC regional RAS6088 project "Strengthening Education and Training Programmes for Medical Physics". Necessary information on the project was collected from the project counterparts via emails for a period of one month, starting from 21st September 2023, and verified at the Final Regional Coordination Meeting in Bangkok, Thailand from 30th October 2023 to 3rd November 2023. Sixty-three participants were trained in 5 Regional Training Courses (RTCs), with 48%, 32% and 20% in radiation therapy, diagnostic radiology, and nuclear medicine, respectively. One RTC was successfully organised to introduce molecular biology as an academic module to participants. Three participating Member States, namely United Arab Emirates (UAE), Nepal and Afghanistan have initiated processes to start the postgraduate master medical physics education programmes by coursework, adopting the IAEA TCS56 Guidelines. UAE has succeeded in completing the process while Nepal and Afghanistan have yet to initiate the programme. The postgraduate master medical physics programmes by coursework were strengthened in Indonesia, Jordan, Malaysia, Pakistan, Syria, and Thailand, along with the national registration of medical physicists. In particular, Thailand has revised 6 postgraduate master medical physics programmes by coursework during the tenure of this project. Home Based Assignment and RTCs have resulted in two publications. In conclusion, the RAS6088 project was found to have achieved its planned outcomes despite challenges faced due to the COVID-19 pandemic. It is proposed that a follow up project be implemented to increase the number of Member States who are better prepared to improve medical physics education and training in the region.


Asunto(s)
Educación Continua , Física Sanitaria , Agencias Internacionales , Medicina Nuclear , Radiología , Radiofármacos/química , Radiofármacos/uso terapéutico , Radiología/educación , Medicina Nuclear/educación , Asia , Física Sanitaria/educación , Cooperación Internacional
2.
J Appl Clin Med Phys ; 25(1): e14232, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38088260

RESUMEN

PURPOSE: This study aims to assess the accuracy of a modified electron beam calibration based on the IAEA TRS-398 and AAPM-TG-51 in multicenter radiotherapy. METHODS: This study was performed using the Elekta and Varian Linear Accelerator electron beams with energies of 4-22 MeV under reference conditions using cylindrical (PTW 30013, IBA FC65-G, and IBA FC65-P) and parallel-plate (PTW 34045, PTW 34001, and IBA PPC-40) chambers. The modified calibration used a cylindrical chamber and an updated k ' Q $k{^{\prime}}_Q$ based on Monte Carlo calculations, whereas TRS-398 and TG-51 used cylindrical and parallel-plate chambers for reference dosimetry. The dose ratio of the modified calibration procedure, TRS-398 and TG-51 were obtained by comparing the dose at the maximum depth of the modified calibration to TRS-398 and TG-51. RESULTS: The study found that all cylindrical chambers' beam quality conversion factors determined with the modified calibration ( k ' Q ) $( {{{k^{\prime}}}_Q} )$ to the TRS-398 and TG-51 vary from 0.994 to 1.003 and 1.000 to 1.010, respectively. The dose ratio of modified/TRS-398cyl and modified/TRS-398parallel-plate, the variation ranges were 0.980-1.014 and 0.981-1.019, while for the counterpart modified/TG-51cyl was found varying between 0.991 and 1.017 and the ratio of modified/TG-51parallel-plate varied in the range of 0.981-1.019. CONCLUSION: This multi-institutional study analyzed a modified calibration procedure utilizing new data for electron beam calibrations at multiple institutions and evaluated existing calibration protocols. Based on observed variations, the current calibration protocols should be updated with detailed metrics on the stability of linac components.


Asunto(s)
Electrones , Fenilpropionatos , Radioterapia de Alta Energía , Humanos , Radioterapia de Alta Energía/métodos , Calibración , Agua , Radiometría/métodos , Fotones
3.
Biomed Phys Eng Express ; 10(1)2023 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-38052064

RESUMEN

Morphological changes can affect distribution of dose in patients. Determination of the dose distribution changes for each fraction radiotherapy can be done by relativein vivodosimetry (IVD). This study analysed the distribution of doses per fraction based on the fluence map recorded by the electronic portal imaging device (EPID) of the patient's transit dose. This research examined cases involving the cervix, breast, and nasopharynx. Transit dose analysis was performed by calculating the gamma index (GI) with composite and field-by-field methods. The gamma passing rate (GPR) value was assessed for its correlation with the subject's body weight. In the case of the nasopharynx, breast, and cervix, the GPR value decreased as the fraction increased. In the case of the nasopharynx, the correlation between the GPR and fraction radiotherapy showed no difference when using either composite or field-by-field methods. However, in cases involving the cervix and breast, there was a difference in the correlation values between the composite and field-by-field methods, where the subject had a significant correlation (p< 0.05) when it was done using a field-by-field method. In addition, the nasopharynx had the highest number of subjects with significant correlation (p< 0.05) between GPR and body weight, followed by the cervix and breast. In the nasopharynx, breast, and cervix, the reproducibility of the dose distribution decreased. This decreased reproducibility was associated with changes in body weight.


Asunto(s)
Radiometría , Planificación de la Radioterapia Asistida por Computador , Femenino , Humanos , Dosificación Radioterapéutica , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Peso Corporal , Electrónica
4.
Biomed Phys Eng Express ; 9(5)2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37442101

RESUMEN

This study aimed to compare absolute calibration outputs based on the protocols of the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398, the American Association of Physicists in Medicine (AAPM) Task Group (TG)-51, and modified calibration approach. The electron beam output calibration followed the IAEA TRS-398 and AAPM TG-51 protocols, both of which required cylindrical chambers and parallel plates. However, the use of cylindrical chambers is not recommended at low energies because of the large fluence-correction factor. TG-51 recommended cross-calibration of the parallel-plate chamber against the cylindrical chamber in a high-energy electron beam. In 2020, an electron beam dosimetry modification was introduced that used a cylindrical ionisation chamber at all energies and updated the data for beam quality conversion factors. This modification provided a lower deviation than that reported in AAPM TG-51. Thus, the modified calibration based on TRS-398 was applied in the present study, which yielded results below the permissible tolerance. The beam calibration at 6, 8, 10, 12, and 15 MeV energies was carried out for two Elekta linear accelerators.. Electron beam dosimetry followed the AAPM TG-51 and TRS-398 protocols, and modified calibration were performed to measure the dose at the maximum depth expressed in dose/monitor units (cGy/MU). Charge-reading measurements were measured using ionisation chambers PTW 30013, IBA CC13, and Exradin A11. The average absorbed dose ratios were 1.004 and 1.009 using the modified calibration and TRS-398 and modified calibration and TG-51, respectively. Therefore, based on IAEA TRS-398, the results were below the tolerance limit (±2%).


Asunto(s)
Energía Nuclear , Fotones , Estados Unidos , Calibración , Electrones , Agua
5.
Z Med Phys ; 2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37365087

RESUMEN

Performing phantom measurements for patient-specific quality assurance (PSQA) adds a significant amount of time to the adaptive radiotherapy procedure. Log file based PSQA can be used to increase the efficiency of this process. This study compared the dosimetric accuracy of high-frequency linear accelerator (Linac) log files and low-frequency log data stored in the oncology information system (OIS). Thirty patients were included, that were recently treated in the head and neck (HN), brain, and prostate region with volumetric modulated arc therapy (VMAT) and an additional ten patients treated using stereotactic body radiation therapy (SBRT) with 3D-conformal radiotherapy (3D-CRT) technique. Log data containing a single fraction were used to calculate the dose distributions. The dosimetric differences between Linac log files and OIS logs were evaluated with a gamma analysis with 2%/2 mm criterion and dose threshold of 30%. The original treatment plan was used as a reference. Moreover, DVH parameters of D98%, D50%, and D2% of the planning-target volume (PTV) and dose to several organs at risk (OARs) were reported. Significant differences in dose distributions between the two log types and the original dose were observed for PTV D98% and D2% (r < 0.001) for HN cases, PTV D98% (r = 0.005) for brain cases, and PTV D50% (r = 0.015) for prostate cases. No significant differences were found between the two log types with respect to D50%. The root mean square (RMS) error of the leaf positions of the OIS log was approximately twice the RMS error of the Linac log file for VMAT plans, but identical for 3D-CRT plans. The relationship between the gamma pass rate and the RMS error showed a moderate correlation for the Linac log files (r = -0.58, p < 0.001) and strong correlation for OIS logs (r = -0.71, p < 0.001). Furthermore, all doses calculated using Linac log files and OIS log data had a GPR >90% for an RMS error < 3.3 mm. Based on these findings, a tolerance limit of RMS error of 3.3 mm for considering OIS log based PSQA was established. Nevertheless, the OIS log data quality should be improved to achieve adequate PSQA.

6.
J Appl Clin Med Phys ; 24(1): e13756, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36001392

RESUMEN

BACKGROUND AND PURPOSE: The lack of equitable access to radiotherapy (RA) linear accelerators (LINACs) is a substantial barrier to cancer care in low- and middle-income countries (LMICs). These nations are expected to bear up to 75% of cancer-related deaths globally by 2030. State-of-the-art LINACs in LMICs experience major issues in terms of robustness, with mechanical and electrical breakdowns resulting in downtimes ranging from days to months. While existing research has identified the higher failure frequency and downtimes between LMICs (Nigeria, Botswana) compared to high-income countries (HICs, the UK), there has been a need for additional data and study particularly relating to multileaf collimators (MLCs). MATERIALS AND METHODS: This study presents for the first time the analysis of data gathered through a dedicated survey and workshop including participants from 14 Indonesian hospitals, representing a total of 19 LINACs. We show the pathways to failure of radiotherapy LINACs and frequency of breakdowns with a focus on the MLC subsystem. RESULTS: This dataset shows that LINACs throughout Indonesia are out of operation for seven times longer than HICs, and the mean time between failures of a LINAC in Indonesia is 341.58 h or about 14 days. Furthermore, of the LINACs with an MLC fitted, 59 . 02 - 1.61 + 1.98 $59.02_{ - 1.61}^{ + 1.98}$ % of all mechanical faults are due to the MLC, and 57 . 14 - 1.27 + 0.78 $57.14_{ - 1.27}^{ + 0.78}$ % of cases requiring a replacement component are related to the MLC. CONCLUSION: These results highlight the pressing need to improve robustness of RT technology for use in LMICs, highlighting the MLC as a particularly problematic component. This work motivates a reassessment of the current generation of RT LINACs and demonstrates the need for dedicated efforts toward a future where cancer treatment technology is robust for use in all environments where it is needed.


Asunto(s)
Oncología por Radiación , Radioterapia de Intensidad Modulada , Humanos , Indonesia , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador/métodos , Nigeria , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
7.
Rep Pract Oncol Radiother ; 28(6): 737-745, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38515817

RESUMEN

Background: This study compared the effectiveness of five deep learning models in constructing non-transit dosimetry with an a-Si electronic portal imaging device (EPID) on Varian Halcyon. Deep learning model is increasingly used to support prediction and decision-making in several fields including oncology and radiotherapy. Materials and methods: Forty-seven unique plans of data obtained from breast cancer patients were calculated using Eclipse treatment planning system (TPS) and extracted from DICOM format as the ground truth. Varian Halcyon was then used to irradiate the a-Si 1200 EPID detector without an attenuator. The EPID and TPS images were augmented and divided randomly into two groups of equal sizes to distinguish the validation and training-test data. Five different deep learning models were then created and validated using a gamma index of 3%/3 mm. Results: Four models successfully improved the similarity of the EPID images and the TPS-generated planned dose images. Meanwhile, the mismatch of the constituent components and number of parameters could cause the models to produce wrong results. The average gamma pass rates were 90.07 ± 4.96% for A-model, 77.42 ± 7.18% for B-model, 79.60 ± 6.56% for C-model, 80.21 ± 5.88% for D-model, and 80.47 ± 5.98% for E-model. Conclusion: The deep learning model is proven to run fast and can increase the similarity of EPID images with TPS images to build non-transit dosimetry. However, more cases are needed to validate this model before being used in clinical activities.

8.
Rep Pract Oncol Radiother ; 27(2): 360-370, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36299381

RESUMEN

Background: This study aimed to evaluate the target volume and dose accuracy in intrafraction cases using 4-dimensional imaging modalities and an in-house dynamic thorax phantom. Intrafraction motion can create errors in the definition of target volumes, which can significantly affect the accuracy of radiation delivery. Motion management using 4-dimensional modalities is required to reduce the risk. Materials and methods: Two variations in both breathing amplitude and target size were applied in this study. From these variations, internal target volume (ITVs) contoured in 10 phases of 4D-CT (ITV10), average intensity projection (AIP), and mid-ventilation (Mid-V) images were reconstructed from all 4D-CT datasets as reference images. Free-breathing (FB), augmentation free-breathing (Aug-FB), and static images were also acquired using the 3D-CT protocol for comparisons. In dose evaluations, the 4D-CBCT modality was applied before irradiation to obtain position correction. Then, the dose was evaluated with Gafchromic film EBT3. Results: The ITV10, AIP, and Mid-V provide GTVs that match the static GTV. The AIP and Mid-V reference images allowed reductions in ITVs and PTVs without reducing the range of target movement areas compared to FB and Aug-FB images with varying percentages in the range of 29.17% to 48.70%. In the dose evaluation, the largest discrepancies between the measured and planned doses were 10.39% for the FB images and 9.21% for the Aug-FB images. Conclusion: The 4D-CT modality can enable accurate definition of the target volume and reduce the PTV. Furthermore, 4D-CBCT provides localization images during registration to facilitate position correction and accurate dose delivery.

9.
Appl Radiat Isot ; 188: 110415, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36027871

RESUMEN

Intensity modulated radiation therapy (IMRT) is an advanced technique in radiation therapy delivery. IMRT depends on the accuracy of the multileaf collimator during treatment. Hence, the actual dose distribution can deviate from the treatment planning system's calculation. This study aimed to perform a multicentre planar dosimetry audit of radiotherapy centres in Indonesia, using the structure sets from AAPM TG-119. The gamma index used to evaluate the dose distribution was 3%/3 mm and 3%/2 mm. We observed 100% gamma index passing rates mostly in the 3%/3 mm evaluations. The gamma index passing rates dropped in the 3%/2 mm analysis. Most of the radiotherapy centres participating in this audit satisfied each criterion's tolerance limit of the action level. This study may become a first result for the next multicenter IMRT audit by using a standardized protocol.


Asunto(s)
Radioterapia de Intensidad Modulada , Indonesia , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
10.
J Appl Clin Med Phys ; 23(4): e13573, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35226389

RESUMEN

PURPOSE: The recently worldwide standard measurement of electron beam reference dosimetry include the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 and Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocols. Muir et al. have modified calibration methods for electron beam calibration based on AAPM TG-51. They found that the use of cylindrical chambers at low energy gave acceptable results. In this study, we propose and report a modified calibration for electron beam based on IAEA TRS-398, the standard reference dosimetry protocol worldwide. METHODS: This work was carried out with energies of 6, 8, 10, 12, and 15 MeV. The electron beam is generated from Elektra Synergy Platform and Versa HD linear accelerator. The charge readings were measured with PTW 30013, IBA CC13, Exradin A1Sl, and Exradin A11 chambers connected to the electrometer. The dose calculation uses an equation of modified calibration for electron beam using the updated k Q ${k_Q}$ factor in previous work. The absorbed dose to water for electron beam is expressed in dose per monitor unit (cGy/MU). Thus, we compared dose per monitor unit (D/MU) calculation using a modified calibration to TRS-398. RESULTS: In this work, we have succeeded in implementing the modified calibration of electron beam based on TRS-398 by applying a cylindrical chamber in all energy beams and using the updated k Q ${k_Q}$ factor. The ratio of the absorbed dose to water between original and modified calibration protocols of TRS-398 (Dw ) for the cylindrical chamber was 1.002 on the Elekta Synergy Platform and 1.000 on the Versa HD while for the parallel-plate chamber it was 1.013 on the Elekta Synergy Platform and 1.014 on the Versa HD. Based on these results, both the cylindrical and parallel-plate chambers are still within the tolerance limit allowed by the TRS-398 protocol, which is ±2%. Therefore, modified calibration based on TRS-398 gives acceptable results and is simpler to use clinically.


Asunto(s)
Energía Nuclear , Fotones , Calibración , Electrones , Humanos , Radiometría/métodos , Agua