Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 61: 1-7, 2012 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-22169467

RESUMEN

A solid phase extraction (SPE) liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method for the determination of GDC-0941 concentrations in human plasma has been developed and validated to support clinical development. An Oasis MCX 10mg 96-well SPE plate was used to extract plasma samples (50 µL) and the resulting extracts were analyzed using reverse-phase chromatography and mass spectrometer coupled with a turbo-ionspray interface. The method was validated over the calibration curve range 0.500-500 ng/mL with linear regression and 1/x(2) weighting. Within-run relative standard deviation (%RSD) ranged from 1.5 to 11.5%, while the between-run %RSD varied from 0.0 to 4.4%. The accuracy ranged from 96.0% to 110.0% of nominal for within-run and 98.0% to 108.0% of nominal for between-run at all concentrations including the LLOQ quality control at 0.500 ng/mL. Extraction recovery of GDC-0941 was between 79.0% and 86.2%. Stability of GDC-0941 was established in human plasma for 602 days at -70 °C and 598 days at -20°C, respectively, and established in reconstituted sample extracts for 167 h when stored at room temperature. Internal standard normalized matrix factor was 1.1, demonstrating that the use of the stable-labeled internal standard GDC-0941-d(8) effectively compensated observed matrix effect and resulting in no adverse impact on the quality of the data produced. This assay was used for the determination of GDC-0941 human plasma concentrations over a sufficient time period to determine pharmacokinetic parameters at relevant clinical doses.


Asunto(s)
Indazoles/sangre , Inhibidores de las Quinasa Fosfoinosítidos-3 , Extracción en Fase Sólida/métodos , Sulfonamidas/sangre , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Femenino , Humanos , Masculino , Fosfatidilinositol 3-Quinasa/metabolismo , Reproducibilidad de los Resultados
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(9-10): 785-90, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-20172765

RESUMEN

To support clinical development, a solid phase extraction (SPE) liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method for the determination of GDC-0449 concentrations in human plasma has been developed and validated. Samples (200 microl) were extracted using an Oasis MCX 10 mg 96-well SPE plate and the resulting extracts were analyzed using reverse-phase chromatography coupled with a turbo-ionspray interface. The method was validated over calibration curve range 5-5000 ng/mL. Quadratic regression and 1/x(2) weighing were used. Within-run relative standard deviation (%RSD) was within 10.1% and accuracy ranged from 88.6% to 109.0% of nominal. Between-run %RSD was within 8.6% and accuracy ranged from 92.4% to 105.3% of nominal. Extraction recovery of GDC-0449 was between 88.3% and 91.2% as assessed using quality control sample concentrations. GDC-0449 was stable in plasma for 315 days when stored at -70 degrees C and stable in reconstituted sample extracts for 117 h when stored at room temperature. Quantitative matrix effect/ion suppression experiment was performed and no significant matrix ion suppression was observed. This assay allows for the determination of GDC-0449 plasma concentrations over a sufficient time period to determine pharmacokinetic parameters at relevant clinical doses.


Asunto(s)
Anilidas/sangre , Cromatografía Liquida/métodos , Proteínas Hedgehog/antagonistas & inhibidores , Proteínas Hedgehog/metabolismo , Piridinas/sangre , Transducción de Señal , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Anilidas/farmacocinética , Humanos , Piridinas/farmacocinética
3.
J Anal Toxicol ; 23(5): 306-12, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10488916

RESUMEN

An assay has been developed for quantitative determination of lysergic acid diethylamide (LSD) and a major metabolite of LSD in human urine at concentrations as low as 10 pg/mL. In most LSD-positive urine samples the metabolite, 2-oxo-3-hydroxy-LSD, is present at higher concentrations than LSD and can be detected for a longer time than LSD after ingestion of the drug. Urine samples are extracted using Varian Bond Elut Certify extraction cartridges. Confirmatory identification is accomplished by trimethylsilylation of LSD and 2-oxo-3-hydroxy-LSD, followed by gas chromatography-tandem mass spectrometry analysis using positive ion chemical ionization and selected reaction monitoring. Commercially available lysergic acid methylpropylamide and 2-oxo-3-hydroxy-LAMPA are used as internal standards. With selected reaction monitoring, both compounds gave linear calibration curves from 10 pg/mL to 5000 pg/mL. Forty-nine human urine samples that had previously been shown to contain LSD were reanalyzed by the new method. These samples showed an average LSD concentration of 357 pg/mL and an average 2-oxo-3-hydroxy-LSD concentration of 3470 pg/mL. Additional experiments using clinical samples in which two subjects were dosed with LSD support the conclusion that analysis for 2-oxo-3-hydroxy-LSD can permit identification of LSD users for a longer period following ingestion than analysis for the parent drug.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Dietilamida del Ácido Lisérgico/análogos & derivados , Dietilamida del Ácido Lisérgico/orina , Detección de Abuso de Sustancias/métodos , Medicina Legal/métodos , Humanos , Dietilamida del Ácido Lisérgico/química , Estándares de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...