1.
AJNR Am J Neuroradiol ; 39(2): 323-330, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29170270

RESUMEN

BACKGROUND AND PURPOSE: Treatment of intracranial bifurcation aneurysms with flow-diverter stents can lead to caliber changes of the distal vessels in a subacute phase. This study aims to evaluate whether local anatomy and flow disruption induced by flow-diverter stents are associated with vessel caliber changes in intracranial bifurcations. MATERIALS AND METHODS: Radiologic images and demographic data were acquired for 25 patients with bifurcation aneurysms treated with flow-diverter stents. Whisker plots and Mann-Whitney rank sum tests were used to evaluate if anatomic data and caliber changes could be linked. Symmetry/asymmetry were defined as diameter ratio 1 = symmetric and diameter ratio <1 = asymmetric. Computational fluid dynamics was performed on idealized and patient-specific anatomies to evaluate flow changes induced by flow-diverter stents in the jailed vessel. RESULTS: Statistical analysis identified a marked correspondence between asymmetric bifurcation and caliber change. Symmetry ratios were lower for cases showing narrowing or subacute occlusion (medium daughter vessel diameter ratio = 0.59) compared with cases with posttreatment caliber conservation (medium daughter vessel diameter ratio = 0.95). Computational fluid dynamics analysis in idealized and patient-specific anatomies showed that wall shear stress in the jailed vessel was more affected when flow-diverter stents were deployed in asymmetric bifurcations (diameter ratio <0.65) and less affected when deployed in symmetric anatomies (diameter ratio ∼1.00). CONCLUSIONS: Anatomic data analysis showed statistically significant correspondence between caliber changes and bifurcation asymmetry characterized by diameter ratio <0.7 (P < .001). Similarly, computational fluid dynamics results showed the highest impact on hemodynamics when flow-diverter stents are deployed in asymmetric bifurcations (diameter ratio <0.65) with noticeable changes on wall sheer stress fields. Further research and clinical validation are necessary to identify all elements involved in vessel caliber changes after flow-diverter stent procedures.


Asunto(s)
Circulación Cerebrovascular , Hemodinámica/fisiología , Aneurisma Intracraneal/terapia , Stents/efectos adversos , Anciano , Femenino , Humanos , Hidrodinámica , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares
2.
J Mech Behav Biomed Mater ; 71: 165-174, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28342324

RESUMEN

Among the cues affecting cells behaviour, mechanical stimuli are known to have a key role in tissue formation and mineralization of bone cells. While soft scaffolds are better at mimicking the extracellular environment, they cannot withstand the high loads required to be efficient substitutes for bone in vivo. We propose a 3D hybrid scaffold combining the load-bearing capabilities of polycaprolactone (PCL) and the ECM-like chemistry of collagen gel to support the dynamic mechanical differentiation of human embryonic mesodermal progenitor cells (hES-MPs). In this study, hES-MPs were cultured in vitro and a BOSE Bioreactor was employed to induce cells differentiation by mechanical stimulation. From day 6, samples were compressed by applying a 5% strain ramp followed by peak-to-peak 1% strain sinewaves at 1Hz for 15min. Three different conditions were tested: unloaded (U), loaded from day 6 to day 10 (L1) and loaded as L1 and from day 16 to day 20 (L2). Cell viability, DNA content and osteocalcin expression were tested. Samples were further stained with 1% osmium tetroxide in order to investigate tissue growth and mineral deposition by micro-computed tomography (µCT). Tissue growth involved volumes either inside or outside samples at day 21 for L1, suggesting cyclic stimulation is a trigger for delayed proliferative response of cells. Cyclic load also had a role in the mineralization process preventing mineral deposition when applied at the early stage of culture. Conversely, cyclic load during the late stage of culture on pre-compressed samples induced mineral formation. This study shows that short bursts of compression applied at different stages of culture have contrasting effects on the ability of hES-MPs to induce tissue formation and mineral deposition. The results pave the way for a new approach using mechanical stimulation in the development of engineered in vitro tissue as replacement for large bone fractures.


Asunto(s)
Células Madre Embrionarias/citología , Estrés Mecánico , Andamios del Tejido , Soporte de Peso , Células Cultivadas , Colágeno/química , Humanos , Poliésteres/química , Ingeniería de Tejidos , Microtomografía por Rayos X
3.
J Mech Behav Biomed Mater ; 65: 478-489, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27665083

RESUMEN

3D polymeric scaffolds are increasingly used for in vitro experiments aiming to mimic the environment found in vivo, to support for cellular growth and to induce differentiation through the application of external mechanical cues. In research, experimental results must be shown to be reproducible to be claimed as valid and the first clause to ensure consistency is to provide identical initial experimental conditions between trials. As a matter of fact, 3D structures fabricated in batch are supposed to present a highly reproducible geometry and consequently, to give the same bulk response to mechanical forces. This study aims to measure the overall mechanical response to compression of commercially available 3D Insert PCL scaffolds (3D PCL) fabricated in series by fuse deposition and evaluate how small changes in the architecture of scaffolds affect the mechanical response. The apparent elastic modulus (Ea) was evaluated by performing quasi-static mechanical tests at various temperatures showing a decrease in material stiffness from 5MPa at 25°C to 2.2MPa at 37°C. Then, a variability analysis revealed variations in Ea related to the repositioning of the sample into the testing machine, but also consistent differences comparing different scaffolds. To clarify the source of the differences measured in the mechanical response, the same scaffolds previously undergoing compression, were scanned by micro computed tomography (µCT) to identify any architectural difference. Eventually, to clarify the contribution given by differences in the architecture to the standard deviation of Ea, their mechanical response was qualitatively compared to a compact reference material such as polydimethylsiloxane (PDMS). This study links the geometry, architecture and mechanical response to compression of 3D PCL scaffolds and shows the importance of controlling such parameters in the manufacturing process to obtain scaffolds that can be used in vitro or in vivo under reproducible conditions.


Asunto(s)
Ensayo de Materiales , Poliésteres/análisis , Andamios del Tejido , Módulo de Elasticidad , Presión , Microtomografía por Rayos X
4.
Rev Sci Instrum ; 81(11): 115107, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21133501

RESUMEN

The microfluidic probe (MFP) consists of a flat, blunt tip with two apertures for the injection and reaspiration of a microjet into a solution--thus hydrodynamically confining the microjet--and is operated atop an inverted microscope that enables live imaging. By scanning across a surface, the microjet can be used for surface processing with the capability of both depositing and removing material; as it operates under immersed conditions, sensitive biological materials and living cells can be processed. During scanning, the MFP is kept immobile and centered over the objective of the inverted microscope, a few micrometers above a substrate that is displaced by moving the microscope stage and that is flushed continuously with the microjet. For consistent and reproducible surface processing, the gap between the MFP and the substrate, the MFP's alignment, the scanning speed, the injection and aspiration flow rates, and the image capture need all to be controlled and synchronized. Here, we present an automated MFP station that integrates all of these functionalities and automates the key operational parameters. A custom software program is used to control an independent motorized Z stage for adjusting the gap, a motorized microscope stage for scanning the substrate, up to 16 syringe pumps for injecting and aspirating fluids, and an inverted fluorescence microscope equipped with a charge-coupled device camera. The parallelism between the MFP and the substrate is adjusted using manual goniometer at the beginning of the experiment. The alignment of the injection and aspiration apertures along the scanning axis is performed using a newly designed MFP screw holder. We illustrate the integrated MFP station by the programmed, automated patterning of fluorescently labeled biotin on a streptavidin-coated surface.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Integración de Sistemas , Hidrodinámica , Inyecciones , Cinética , Microscopía , Movimiento (Física) , Programas Informáticos , Propiedades de Superficie
5.
Diabetologia ; 47(10): 1722-6, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15517153

RESUMEN

AIMS/HYPOTHESIS: Clinical complications associated with diabetes may be related to altered physical properties of leucocytes. We used micropipette techniques to examine leucocyte rheology (specifically lymphocyte rheology) in the non-obese diabetic (NOD) mouse model of diabetes mellitus. We hypothesised that diabetes affects lymphocyte rheology, and specifically that lymphocyte membranes from diabetic mammals have a higher cortical tension than those from non-diabetic mammals. METHODS: Lymphocytes were isolated from diabetic and control mice. Lymphocyte deformation and activation were assessed with a micropipette apparatus. Cellular activation was assessed visually. Projection length into the micropipette during aspiration was used to calculate the viscosity of the cell. Recovery length following expulsion from the micropipette was used to derive the recovery time constant, which is the ratio of cortical tension : viscosity (T(o)/mu) for each cell. The cell cortical/surface tension was calculated from this ratio. RESULTS: Of 692 control lymphocytes, 29% were spontaneously activated compared with 39% of 624 diabetic cells (p<0.06) and 31.5% of 315 non-diabetic NOD cells (p=0.14). Viscosity values for diabetic lymphocytes were equivalent to those for control cells (1345.12+/-1420.97 Pa.s vs 996.84+/-585.07 Pa.s, p=0.13). The average T(o)/micro value for diabetic lymphocytes (35.4+/-16.5x10(-6) cm/s) was significantly higher than that for control cells (24.8+/-11.3x10(-6) cm/s, p<0.03) and cells from non-diabetic NOD mice (26.3+/-9.0x10(-6) cm/s, p<0.005). The mean cortical tension values for diabetic and control cells were 4.7+/-2.3x10(-4) N/m and 2.8+/-0.7x10(-4) N/m respectively (p<0.003). CONCLUSIONS/INTERPRETATION: Lymphocytes from diabetic mice tend to spontaneously activate. They have an equivalent cytoplasmic viscosity but a larger recovery time constant compared with cells from control mice. The results suggest that diabetic lymphocytes are stiffer than control cells.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Linfocitos/fisiología , Animales , Diabetes Mellitus Tipo 1/inmunología , Activación de Linfocitos , Linfocitos/inmunología , Ratones , Ratones Endogámicos NOD , Reología