Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Med Cases ; 12(3): 90-93, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34434436

RESUMEN

Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease that has low survival rate without surgical correction. This report is about a rare case of acute ST elevation myocardial infarction in a 46-year-old patient with uncorrected TOF that was successfully treated with low-dose intracoronary thrombolysis.

2.
Angiology ; 70(8): 756-764, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30665308

RESUMEN

OBJECTIVES: To evaluate the angiographic and intravascular ultrasound (IVUS) characteristics of coronary mismatch lesions. BACKGROUND: Better understanding about the characteristics of mismatch lesions may help to achieve more accurate lesion assessment and, thereby, to improve the outcomes of percutaneous coronary intervention (PCI). METHODS: Angiographic and IVUS data from 1369 lesions were analyzed. Mismatch lesion was defined as the difference between proximal and distal reference lumen diameters of ≥1.0 mm or ≥30% of the distal reference lumen diameter. RESULTS: The incidence of mismatch lesions was 20.1% (275/1369). Compared to nonmismatch group, mismatch group had longer lesions (21.3 [6.4] mm vs 18.4 [6.4] mm, P < .001) with smaller minimum lumen diameter (0.87 [0.29] mm vs 1.10 [0.31] mm, P < .001) and more severe diameter stenosis (78.8% [9.2%] vs 66.3% [10.3%], P < .001). On IVUS, mismatch group had larger lumen area (18.7 [5.0] vs 15.8 [5.1] mm2, P < .001) but lower plaque burden at the proximal reference segment (41.0% [9.2%] vs 45.7% [9.9%], P < .001) and smaller lumen area (4.83 [1.89] vs 7.36 [2.89] mm, P < .001) but higher plaque burden at the distal reference segment (42.9% [10.4%] vs 41.4% [10.1%], P = .023). Multivariable logistic regression analysis showed that mismatch lesions were frequently accompanied by diffuse lesions (odds ratio [OR] = 2.50; 95% confidence interval [CI]: 1.83-3.40; P < .001), bifurcation lesions (OR = 5.83; 95% CI: 4.40-7.74; P < .001), and lesions with a low TIMI flow grade (OR = 1.70; 95% CI: 1.08-2.67; P = .022) or severe diameter stenosis (OR = 3.05; 95% CI: 2.10-4.43; P < .001). CONCLUSIONS: Mismatch lesions are quite common and characterized by greater lesion complexity compared with nonmismatch lesions. Further studies may be necessary to address the impact of this lesion type on the outcome of PCI.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/patología , Vasos Coronarios/patología , Ultrasonografía Intervencional , Adulto , Anciano , Angiografía Coronaria/métodos , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Valor Predictivo de las Pruebas , Ultrasonografía Intervencional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...