Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Electrocardiol ; 49(4): 522-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27199031

RESUMEN

INTRODUCTION: The incidence of pacemaker-mediated tachycardia (PMT) varies as a function of patient characteristics, device programming and algorithm specificities. We investigated the efficacy of the Boston Scientific algorithm by reviewing PMT episodes in a large device population. METHODS: In this multicenter study, we included 328 patients implanted with a Boston Scientific device: 157 non-dependent patients with RYTHMIQ™ activated (RYTHMIQ group), 76 patients with permanent AV-conduction disorder (AV-block group) and 95 Cardiac Resynchronization Therapy patients (CRT group). For each patient, we reviewed the last 10 remote monitoring-transmitted EGMs diagnosed as PMT. RESULTS: We analyzed 784 PMT episodes across 118 patients. In the RYTHMIQ group, the diagnosis of PMT was correct in most episodes (80%) of which 69% was directly related to the prolongation of the AV-delay associated with the RYTHMIQ algorithm. The usual triggers for PMT were also observed (PVC 16%, PAC 9%). The remainder of the episodes (20%) in RYTHMIQ patients and most episodes of AV-block (66%) and CRT patients (74%) were incorrectly diagnosed as PMT during sinus tachycardia at the maximal tracking rate. The inappropriate intervention of the algorithm during exercise causes non-conducted P-waves, loss of CRT (sustained in six patients) and may have been pro-arrhythmogenic in one patient (induction of ventricular tachycardia). CONCLUSION: Algorithms to minimize ventricular pacing can occasionally have unintended consequences such as PMT. The PMT algorithm in Boston Scientific devices is associated with a high rate of incorrect PMT diagnosis during exercise resulting in inappropriate therapy with non-conducted P-waves, loss of CRT and limited risk of pro-arrhythmic events.


Asunto(s)
Algoritmos , Diagnóstico por Computador/instrumentación , Electrocardiografía/instrumentación , Marcapaso Artificial/estadística & datos numéricos , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/prevención & control , Terapia Asistida por Computador/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico por Computador/estadística & datos numéricos , Electrocardiografía/estadística & datos numéricos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Francia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Terapia Asistida por Computador/estadística & datos numéricos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA