Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Orthop Surg Res ; 18(1): 279, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-37020305

RESUMEN

BACKGROUND: Scapulothoracic orientation, especially scapular internal rotation (SIR) may influence range of motion in reverse total shoulder arthroplasty (RTSA) and is subjected to body posture. Clinical measurements of SIR rely on apical bony landmarks, which depend on changes in scapulothoracic orientation, while radiographic measurements are often limited by the restricted field of view (FOV) in CT scans. Therefore, the goal of this study was (1) to determine whether the use of CT scans with a limited FOV to measure SIR is reliable and (2) if a clinical measurement could be a valuable alternative. METHODS: This anatomical study analyzed the whole-body CT scans of 100 shoulders in 50 patients (32 male and 18 female) with a mean age of 61.2 ± 20.1 years (range 18; 91). (1) CT scans were rendered into 3D models and SIR was determined as previously described. Results were compared to measurements taken in 2D CT scans with a limited FOV. (2) Three apical bony landmarks were defined: (the angulus acromii (AA), the midpoint between the AA and the coracoid process tip (C) and the acromioclavicular (AC) joint. The scapular axis was determined connecting the trigonum scapulae with these landmarks and referenced to the glenoid center. The measurements were repeated with 0°, 10°, 20°, 30° and 40° anterior scapular tilt. RESULTS: Mean SIR was 44.8° ± 5.9° and 45.6° ± 6.6° in the 3D and 2D model, respectively (p < 0.371). Mean difference between the measurements was 0.8° ± 2.5° with a maximum of 10.5°. Midpoint AA/C showed no significant difference to the scapular axis at 0° (p = 0.203) as did the AC-joint at 10° anterior scapular tilt (p = 0.949). All other points showed a significant difference from the scapular axis at all degrees of tilt. CONCLUSION: 2D CT scans are reliable to determine SIR, even if the spine is not depicted. Clinical measurements using apical superficial scapula landmarks are a possible alternative; however, anterior tilt influenced by posture alters measured SIR.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Masculino , Femenino , Adolescente , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Artroplastia , Escápula/cirugía , Postura , Rango del Movimiento Articular , Fenómenos Biomecánicos , Hombro/cirugía
2.
Arch Orthop Trauma Surg ; 143(7): 3871-3878, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36175674

RESUMEN

BACKGROUND: Periprosthetic joint infections (PJI) are a major concern in shoulder arthroplasty, which in some cases require two-stage exchange. While it was shown that low-virulence bacteria are the most isolated pathogens in shoulder PJI, little is known about changes in microbiological spectrum and resistance patterns during two-stage revision. METHODS: This retrospective study included all patients (n = 25) who received a two-stage revision from January 2011 to December 2020 for shoulder PJI in one institution. Microbiological spectrum, antimicrobial resistance patterns, and re-revision rates of culture positive first- and second-stage procedures were analyzed. The mean follow-up time was 29.7 months (range 8; 115 months). At final follow-up, subjective shoulder value (SSV) and visual analog scale (VAS) score for pain and satisfaction with the surgery were assessed. RESULTS: In 25 patients, a total of 54 2-stage exchange procedures were performed and positive cultures were obtained in 36 of these surgeries (66.7%). A total of 7 out of 25 patients (28.0%) showed a positive microbiological culture at first and second stages. In those patients, the mean time between first and second stages was 30.9 weeks (range 6; 70). Three out of those seven patients (42.9%) had a polymicrobial spectrum with one microorganism persistent at stage two, including Cutibacterium acnes (n = 1) and Staphylococcus epidermidis (MRSE) (n = 2). In all these cases, antimicrobial resistance patterns changed. All cultures with monomicrobial spectrum (n = 4) at first stage showed a changed spectrum. Patients with positive first- and second-stage revisions showed a mean SSV of 49.3% ± 23.5 versus 52.9% ± 29.5 in single positive patients (p = 0.76). Re-revision was performed in five cases, two of those in patients with positive first- and second-stage cultures. CONCLUSION: There is a high rate of changes in microbiological spectrum and resistance patterns between culture positive first- and second-stage procedures as well as subsequent re-revisions. Intraoperative samples during reimplantation should be taken and resistance reconsidered in case of re-revision.


Asunto(s)
Antiinfecciosos , Infecciones Relacionadas con Prótesis , Articulación del Hombro , Humanos , Hombro , Estudios Retrospectivos , Articulación del Hombro/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Antibacterianos/uso terapéutico , Reoperación/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA