Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(11)2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35684861

RESUMEN

The development of a piezoresistive coating produced from dispersing graphene nanoplatelets (GNPs) inside a commercial water-based polyurethane paint is presented. The feasibility of its exploitation for realizing highly sensitive discrete strain sensors and to measure spatial strain distribution using linear and two-dimensional depositions was investigated. Firstly, the production process was optimized to achieve the best electromechanical response. The obtained materials were then subjected to different characterizations for structural and functional investigations. Morphological analyses showed a homogenous dispersion of GNPs within the host matrix and an average thickness of about 75 µm of the obtained nanostructured films. By several adhesion tests, it was demonstrated that the presence of the nanostructures inside the paint film lowered the adhesion strength by only 20% in respect to neat paint. Through electrical tests, the percolation curve of the nanomaterial was acquired, showing an effective electrical conductivity ranging from about 10-4 S/m to 3.5 S/m in relation to the different amounts of filler dispersed in the neat paint: in particular, samples with weight fractions of 2, 2.5, 3, 3.5, 4, 5 and 6 wt% of GNPs were produced and characterized. Next, the sensitivity to flexural strain of small piezoresistive sensors deposited by a spray-coating technique on a fiberglass-reinforced epoxy laminate beam was measured: a high gauge factor of 33 was obtained at a maximum strain of 1%. Thus, the sensitivity curve of the piezoresistive material was successively adopted to predict the strain along a multicontact painted strip on the same beam. Finally, for a painted laminate plate subjected to a mechanical flexural load, we demonstrated, through an electrical resistance tomography technique, the feasibility to map the electrical conductivity variations, which are strictly related to the induced strain/stress field. As a further example, we also showed the possibility of using the coating to detect the presence of conducting objects and damage.

2.
Polymers (Basel) ; 10(1)2018 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-30966116

RESUMEN

Recently, graphene-polymer composites gained a central role in advanced stress and strain sensing. A fundamental step in the production of epoxy-composites filled with graphene nanoplatelets (GNPs) consists in the exfoliation and dispersion of expanded graphite in a proper solvent, in the mixing of the resulting GNP suspension with the polymer matrix, and in the final removal of the solvent from the composite before curing through evaporation. The effects of traces of residual solvent on polymer curing process are usually overlooked, even if it has been found that even a small amount of residual solvent can affect the mechanical properties of the final composite. In this paper, we show that residual traces of N,N'-Dimethylformamide (DMF) in vinylester epoxy composites can induce relevant variations of the electrical, mechanical and electromechanical properties of the cured GNP-composite. To this purpose, a complete analysis of the morphological and structural characteristics of the composite samples produced using different solvent mixtures (combining acetone and DMF) is performed. Moreover, electrical, mechanical and electromechanical properties of the produced composites are assessed. In particular, the effect on the piezoresistive response of the use of DMF in the solvent mixture is analyzed using an experimental strain dependent percolation law to fit the measured electromechanical data. It is shown that the composites realized using a higher amount of DMF are characterized by a higher electrical conductivity and by a strong reduction of Young's Modulus.

3.
Eur Radiol ; 23(8): 2087-94, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23620367

RESUMEN

OBJECTIVE: To evaluate the clinical value of combining one-view mammography (cranio-caudal, CC) with the complementary view tomosynthesis (mediolateral-oblique, MLO) in comparison to standard two-view mammography (MX) in terms of both lesion detection and characterization. METHODS: A free-response receiver operating characteristic (FROC) experiment was conducted independently by six breast radiologists, obtaining data from 463 breasts of 250 patients. Differences in mean lesion detection fraction (LDF) and mean lesion characterization fraction (LCF) were analysed by analysis of variance (ANOVA) to compare clinical performance of the combination of techniques to standard two-view digital mammography. RESULTS: The 463 cases (breasts) reviewed included 258 with one to three lesions each, and 205 with no lesions. The 258 cases with lesions included 77 cancers in 68 breasts and 271 benign lesions to give a total of 348 proven lesions. The combination, DBT(MLO)+MX(CC), was superior to MX (CC+MLO) in both lesion detection (LDF) and lesion characterization (LCF) overall and for benign lesions. DBT(MLO)+MX(CC) was non-inferior to two-view MX for malignant lesions. CONCLUSIONS: This study shows that readers' capabilities in detecting and characterizing breast lesions are improved by combining single-view digital breast tomosynthesis and single-view mammography compared to two-view digital mammography. KEY POINTS: • Digital breast tomosynthesis is becoming adopted as an adjunct to mammography (MX) • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion detection (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in cancer detection • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion characterization (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in characterization of malignant lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagenología Tridimensional/métodos , Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Mama/patología , Reacciones Falso Positivas , Femenino , Humanos , Persona de Mediana Edad , Imagen Multimodal/métodos , Variaciones Dependientes del Observador , Curva ROC , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados
4.
Eur Radiol ; 23(3): 664-72, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22976919

RESUMEN

OBJECTIVE: To determine the performance of combined single-view mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus single-view cranio-caudal (CC) mammography (MX) compared with that of standard two-view digital mammography. METHODS: A multi-reader multi-case (MRMC) receiver-operating characteristic (ROC) study was conducted, involving six breast radiologists. Two hundred fifty patients underwent bilateral MX and DBT imaging. MX and DBT images with the adjunct of the CC-MX view from 469 breasts were evaluated and rated independently by six readers. Differences in mean areas under the ROC curves (AUCs), mean sensitivity and mean specificity were analysed by analysis of variance (ANOVA) to assess clinical performance. RESULTS: The combined technique was found to be non-inferior to standard two-view mammography (MX((CC+MLO))) in mean AUC (difference: +0.021;95 % LCL = -0.011), but was not statistically significant for superiority (P = 0.197). The combined technique had equivalent sensitivity to standard mammography (76.2 % vs. 72.8 %, P = 0.269) and equivalent specificity (84.9 % vs. 83.0 %, P = 0.130). Specificity for benign lesions was significantly higher with the combination of techniques versus mammography (45.6 % vs. 36.8 %, P = 0.002). CONCLUSION: In this enriched study population, the combination of single-view MLO tomosynthesis plus single-view CC mammography was non-inferior to that of standard two-view digital mammography in terms of ROC curve area, sensitivity and specificity.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagenología Tridimensional/métodos , Mamografía/métodos , Posicionamiento del Paciente/métodos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Eur Radiol ; 20(7): 1545-53, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20033175

RESUMEN

OBJECTIVE: To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. METHODS: The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. RESULTS: Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. CONCLUSION: Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/patología , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Variaciones Dependientes del Observador , Curva ROC , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA