Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
J Chromatogr A ; 1713: 464518, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38000199

RESUMEN

Organic-silica hybrid monolithic materials have attracted considerable attention as potential stationary phases in separation science. These materials combine the advantages of organic polymer and silica-based monoliths, including easy preparation, lower back pressure, high permeability, excellent mechanical strength, thermal stability, and tunable surface chemistry with high surface area and selectivity. The outstanding chromatographic efficiency as stationary phase of hybrid monolithic capillary columns for capillary liquid chromatography and capillary electrochromatography has been reported in many papers. Organic-silica hybrid monolithic materials have also been extensively used in the field of sample preparation. Owing to their surface functionalities, these porous sorbents offer unique selectivity for pre-concentration of different analytes in the most complex matrixes by fast dynamic transport. These sorbents not only improve the analytical method sensitivity, but also introduce novelties in terms of extraction devices and instrument coupling strategies. The current review covers the period spanning from 2017 to 2023 and describes the properties of organic-inorganic hybrid monolithic materials, the present status of this technology and summarizes recent developments in their use as innovative sorbents for microextraction sample preparation techniques (solid phase microextraction with pipette tip, offline in-tube SPME, in-tube SPME online with LC, and in-tube SPME directly coupled with mass spectrometry). Aspects such as the synthesis methods (sol-gel process, one-pot approach, and polyhedral oligomeric silsesquioxanes-based procedure), characterization techniques, and strategies to improve extraction efficiency in various applications in different areas (environmental, food, bioanalysis, and proteomics) are also discussed.


Asunto(s)
Electrocromatografía Capilar , Dióxido de Silicio , Dióxido de Silicio/química , Cromatografía Liquida/métodos , Electrocromatografía Capilar/métodos , Microextracción en Fase Sólida/métodos , Polímeros
2.
J Clin Psychopharmacol ; 43(4): 339-349, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37335211

RESUMEN

BACKGROUND: Serotonergic hallucinogens and cannabinoids may alter the recognition of emotions in facial expressions (REFE). Cannabidiol (CBD) attenuates the psychoactive effects of the cannabinoid-1 agonist tetrahydrocannabinol. Ayahuasca is a dimethyltryptamine-containing hallucinogenic decoction. It is unknown if CBD may moderate and attenuate the effects of ayahuasca on REFE. PROCEDURES: Seventeen healthy volunteers participated in a 1-week preliminary parallel-arm, randomized controlled trial for 18 months. Volunteers received a placebo or 600 mg of oral CBD followed by oral ayahuasca (1 mL/kg) 90 minutes later. Primary outcomes included REFE and empathy tasks (coprimary outcome). Tasks were performed at baseline and 6.5 hours, 1 and 7 days after the interventions. Secondary outcome measures included subjective effects, tolerability, and biochemical assessments. RESULTS: Significant reductions (all P values <0.05) only in reaction times were observed in the 2 tasks in both groups, without between-group differences. Furthermore, significant reductions in anxiety, sedation, cognitive deterioration, and discomfort were observed in both groups, without between-group differences. Ayahuasca, with or without CBD, was well tolerated, producing mainly nausea and gastrointestinal discomfort. No clinically significant effects were observed on cardiovascular measurements and liver enzymes. CONCLUSIONS: There was no evidence of interactive effects between ayahuasca and CBD. The safety of separate and concomitant drug intake suggests that both drugs could be applied to clinical populations with anxiety disorders and in further trials with larger samples to confirm findings.


Asunto(s)
Banisteriopsis , Cannabidiol , Humanos , Cannabidiol/efectos adversos , Cognición Social , Estudios de Factibilidad , Dronabinol/farmacología , Agonistas de Receptores de Cannabinoides , Método Doble Ciego
3.
Anal Bioanal Chem ; 415(18): 4003-4021, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36877264

RESUMEN

Alzheimer's disease (AD), a neurological disorder, is a major public health concern and the most common form of dementia. Its typical symptoms include memory loss, confusion, changes in personality, and cognitive impairment, which result in patients gradually losing independence. Over the last decades, some studies have focused on searching for effective biomarkers as early diagnostic indicators of AD. Amyloid-ß (Aß) peptides have been consolidated as reliable AD biomarkers and have been incorporated into modern diagnostic research criteria. However, quantitative analysis of Aß peptides in biological samples remains a challenge because both the sample and the physical-chemical properties of these peptides are complex. During clinical routine, Aß peptides are measured in the cerebrospinal fluid by immunoassays, but the availability of a specific antibody is critical-in some cases, an antibody may not exist, or its specificity may be inadequate, leading to low sensitivity and false results. HPLC-MS/MS has been reported as a sensitive and selective method for determining different fragments of Aß peptides in biological samples simultaneously. Developments in sample preparation techniques (preconcentration platforms) such as immunoprecipitation, 96-well plate SPME, online SPME, and fiber-in-tube SPME have enabled not only effective enrichment of Aß peptides present at trace levels in biological samples, but also efficient exclusion of interferents from the sample matrix (sample cleanup). This high extraction efficiency has provided MS platforms with higher sensitivity. Recently, methods affording LLOQ values as low as 5 pg mL-1 have been reported. Such low LLOQ values are adequate for quantifying Aß peptides in complex matrixes including cerebrospinal fluid (CSF) and plasma samples. This review summarizes the advances in mass spectrometry (MS)-based methods for quantifying Aß peptides and covers the period 1992-2022. Important considerations regarding the development of the HPLC-MS/MS method such as the sample preparation step, optimization of the HPLC-MS/MS parameters, and matrix effects are described. Clinical applications, difficulties related to analysis of plasma samples, and future trends of these MS/MS-based methods are also discussed.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Humanos , Péptidos beta-Amiloides/química , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión , Enfermedad de Alzheimer/diagnóstico , Anticuerpos , Biomarcadores/líquido cefalorraquídeo , Fragmentos de Péptidos/química
4.
Talanta ; 254: 124186, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36521326

RESUMEN

Current research efforts at neurological diseases have focused on identifying novel biomarkers to aid in diagnosis, to provide accurate prognostic information, and to monitor disease progression. This study presents the direct coupling of fiber-in-tube solid-phase microextraction to tandem mass spectrometry as a reliable method to determine amyloid beta peptides (Aß38, Aß40, and Aß42) as biomarkers for Alzheimer's disease in cerebrospinal fluid (CSF) samples. To obtain the biocompatible fiber-in-tube SPME capillary, a PEEK tube segment was longitudinally packed with fine fibers [nitinol wires coated with a zwitterionic polymeric ionic liquid], to act as selective extraction medium. The fiber-in-tube SPME-MS/MS method integrated analyte extraction/enrichment and sample cleanup (exclusion of interferents) into one step. The method provided lower limits of quantification (LLOQ: 0.2 ng mL-1 for Aß38 and 0.1 ng mL-1 for Aß40 and Aß42), high precision (CV lower than 11.6%), and high accuracy (relative standard deviation lower than 15.1%). This method was successfully applied to determine Aß peptides in CSF samples obtained from AD patients (n = 8) and controls (healthy volunteers, n = 10). Results showed that Aß42 levels in the CSF samples obtained from AD patients were significantly lower compared to healthy controls (p < 0.05). On the basis of the ROC analysis results, the Aß42/Aß40 ratio (AUC = 0.950, p < 0.01; 95%) performed significantly better than Aß42 alone (AUC = 0.913, p < 0.01; 95%) in discriminating between AD patients and healthy controls and presented better diagnostic ability for AD. The novelties of this study are not only related to evaluating Aß peptides as AD biomarkers, but also to demonstrating direct online coupling of fiber-in-tube SPME with MS/MS as a quantitative high-throughput method for bioanalysis.


Asunto(s)
Enfermedad de Alzheimer , Microextracción en Fase Sólida , Espectrometría de Masas en Tándem , Humanos , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/líquido cefalorraquídeo , Péptidos beta-Amiloides/líquido cefalorraquídeo , Péptidos beta-Amiloides/química , Biomarcadores , Fragmentos de Péptidos , Microextracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos
5.
Anal Chim Acta ; 1226: 340160, 2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36068070

RESUMEN

This manuscript describes the development of magnetic restricted-access carbon nanotubes (M-RACNTs) for use as SPME sorbent to determine cannabidiol (CBD) and delta-9-tetrahydrocannabinol (THC) in human plasma samples by UHPLC-MS/MS. The adsorptive phase was immobilized on an SPME device by electromagnetic interactions between the M-RACNTs and a cylindrical neodymium magnet (3-mm diameter x 8-mm height) attached to a stainless-steel rod (3-mm diameter x 40-mm height). The M-RACNTs were synthesized by incorporating Fe3O4 magnetic nanoparticles (MNPs) into commercial carbon nanotubes (CNTs); then the surface of the resulting sorbent was further coated with a layer of bovine serum albumin (BSA). Characterization techniques (SEM, FTIR, and Zeta potential) confirmed the presence of both MNPs and BSA layer dispersed through the structure of the CNTs. The M-RACNTs presented adequate sorption capacity, stable physical/chemical characteristics, and appropriate magnetic properties. Protein exclusion capacity (about 98.5%) was attributed to the chemical diffusion barrier created by the BSA network at the outer surface of the sorbent. The SPME parameters (sample pH, equilibrium time, and desorption conditions) were optimized by design of experiments (fraction factorial planning). The method (validated according to the FDA guidelines) presented adequate selectivity and linearity (coefficient of determination higher than 0.99) at concentrations ranging from the lower limit of quantification (LLOQ) (10 ng mL-1) to the upper limit of quantification (ULOQ) (300 ng mL-1) for both CBD and THC. Precision and accuracy varied from 4.47 to 19.84% (LLOQ) and -6.90 to 17.78% (LLOQ), respectively. Carry-over and matrix effect were not significant. The method was successfully applied to determine plasmatic CBD levels in healthy volunteers attending a single session of oral drug administration and THC levels in frequent cannabis smokers.


Asunto(s)
Cannabinoides , Nanotubos de Carbono , Cannabinoides/análisis , Cromatografía Líquida de Alta Presión/métodos , Dronabinol/análisis , Humanos , Fenómenos Magnéticos , Nanotubos de Carbono/química , Microextracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos
6.
J Chromatogr A ; 1668: 462925, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35263675

RESUMEN

Miniaturized liquid chromatography (LC) has been recognized as one of the most important analytical methods in several research fields. Reduced analytical work-scale provides superior chromatographic resolution and decreases sample and organic solvent consumption. However, frequent clogging of tubing connections and use of small sample volumes are significant limitations when high throughput and sensitive analyses are required. Effective sample preparation could help to overcome these limitations. Online coupling of sample preparation techniques (such as column switching and in-tube solid-phase microextraction) with these miniaturized systems may result in more sensitive and reproducible analyses, improving analytical efficiency. This review describes the most common online miniaturized LC configurations, and the main applications of current online sample preparation techniques coupled to miniaturized LC systems in the bioanalytical, omics, and environmental areas. Relevant features, and challenges of these systems, and innovative sorbents, including restricted access materials, monoliths, and immunosorbents is also discussed.


Asunto(s)
Microextracción en Fase Sólida , Manejo de Especímenes , Cromatografía Liquida/métodos , Inmunoadsorbentes , Microextracción en Fase Sólida/métodos , Solventes
7.
J Huntingtons Dis ; 11(1): 91-95, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35124656

RESUMEN

Huntington's disease (HD) is an inherited neurodegenerative disease characterized by motor, cognitive and behavioral deficits. Some evidence suggests that the endocannabinoid system participates in the pathophysiology of HD. We conducted a cross-sectional study comparing plasma levels of anandamide and 2-arachidonoylglycerol in manifest HD gene-expansion carriers (HDGEC) and healthy controls, finding no difference in endocannabinoid levels between the groups. Correlations between endocannabinoid levels and clinical scales (Mini-Mental State Examination, Hospital Anxiety and Depression Scale, Unified Huntington Disease Rating Scale) were non-significant. We found a significant association between body mass index and anandamide levels in healthy controls but not in HDGEC.


Asunto(s)
Enfermedad de Huntington , Enfermedades Neurodegenerativas , Estudios Transversales , Endocannabinoides , Heterocigoto , Humanos
8.
Hum Psychopharmacol ; 37(4): e2834, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35107855

RESUMEN

OBJECTIVE: To assess endocannabinoid (anandamide, AEA; 2-arachidonoylglycerol, 2-AG) plasma levels in healthy volunteers and in volunteers with social anxiety disorder (SAD) after a single oral dose of ayahuasca or placebo. METHODS: Post hoc analysis of endocannabinoid plasma levels (baseline, 90 and 240 min after drug intake) from two parallel-group, randomized, placebo-controlled trials. In Study 1, 20 healthy volunteers ingested ayahuasca (average 1.58 mg/ml dimethyltryptamine (DMT)) or placebo, and in Study 2, 17 volunteers with SAD received ayahuasca (average 0.680 mg/ml DMT) or placebo. RESULTS: A significant difference was observed in AEA concentrations in Study 2 after ayahuasca intake (Χ2 (2) = 6.5, p = 0.03, Friedman test), and near significant differences (increases) were observed between baseline and 90 (Z = 0, p = 0.06, Wilcoxon test) and 240 (Z = 10, p = 0.06) minutes after ayahuasca intake. CONCLUSIONS: Although our findings suggest that ayahuasca could modulate AEA levels in SAD patients, the high interindividual variability in both trials and the small samples preclude definitive conclusions. More research with larger samples is needed to better understand the effects of ayahuasca and other hallucinogens in the endocannabinoid system.


Asunto(s)
Banisteriopsis , Alucinógenos , Fobia Social , Endocannabinoides , Voluntarios Sanos , Humanos , N,N-Dimetiltriptamina/farmacología , Fobia Social/tratamiento farmacológico
9.
Anal Chim Acta ; 1193: 339394, 2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35058015

RESUMEN

Alzheimer disease (AD) is a neurodegenerative disorder characterized by extracellular accumulation of amyloid-ß peptide (Aß) in the brain interstitium. Human serum albumin (HSA) highly binds to Aß in blood plasma and is thought to inhibit plaque formation in peripheral tissue. Thus, the evaluation of albumin binding to Aß is an important key to understand the dynamics of these molecules in the biological system of patients with AD. In this work, a fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to estimate Aß fraction binding to HSA in cerebrospinal fluid (CSF) and plasma samples. Crosslinked zwitterionic polymeric ionic liquid (zwitterionic PIL)-coated nitinol wires were developed and packed into a polyether ether ketone (PEEK) capillary for a fiber-in-tube SPME and UHPLC-MS/MS method. Zwitterionic PIL sorbent was synthetized from 1-vinyl-3-(butanesulfonate)imidazolium ([VIm+C4SO3-]) and 1,12-di(3-vinylimidazolium)dodecane dibromide ([(VIm)2C12]2[Br]) monomers by in-situ thermally-initiated polymerization. Morphological characterization by scanning electron microscopy (SEM) and atomic force microscopy (AFM) revealed a decrease in the surface roughness of the nitinol wires from ∼17 nm to 1 nm after the in-situ polymerization. The zwitterionic PIL sorbent selectively preconcentrates Aß through a two-pronged interaction mechanism. The fiber-in-tube SPME and UHPLC-MS/MS method presented lower limits of quantification (LLOQ) of 0.4 ng mL-1 for Aß38 and 0.3 ng mL-1 for Aß40 and Aß42, a linear range from LLOQ values to 15 ng mL-1 with coefficients of determination higher than 0.99, precision with coefficient of variation (CV) values ranging from 2.1 to 7.3% and accuracy with relative standard deviation (RSD) values from -0.3 to 7.4. This method was successfully applied to evaluate the binding of HSA to Aß in cerebrospinal fluid (CSF) and plasma samples.


Asunto(s)
Péptidos beta-Amiloides , Líquidos Iónicos , Aleaciones , Proteínas Portadoras , Cromatografía Líquida de Alta Presión , Humanos , Microextracción en Fase Sólida , Espectrometría de Masas en Tándem
10.
Front Psychiatry ; 12: 688439, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34421675

RESUMEN

Rationale: Previous studies with the serotonergic hallucinogens LSD and psilocybin showed that these drugs induced changes in personality traits, such as increases in Openness. However, results are inconsistent, and the effects of ayahuasca on personality were never investigated in a controlled trial. Objectives: To assess the effects of ayahuasca on personality in two randomized, placebo-controlled trials in healthy volunteers. Methods: Data from two parallel-group, randomized, placebo-controlled trials in healthy volunteers were included. In the first trial, 15 volunteers ingested ayahuasca or placebo, while in the second trial 15 volunteers received placebo+ayahuasca or cannabidiol (CBD)+ayahuasca. Personality was assessed with the NEO-Five Factor Inventory (NEO-FFI) at baseline and 21 days post-treatment. Results: There were significant differences between groups in baseline Openness scores, but not on day 21. A significant increase in Openness scores was observed in the placebo + ayahuasca group in study 2. No other within-group differences were observed for any other domain. Conclusions: Ayahuasca produced inconsistent effects on personality since it induced significant increase in Openness 21 days post-drug intake only in one of the trials. The absence of significant differences in the other ayahuasca groups could be due to small sample sizes and baseline differences among groups. The effects of ayahuasca and other serotonergic hallucinogens on personality should be further investigated in clinical samples.

11.
Anal Chim Acta ; 1165: 238110, 2021 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-33975700

RESUMEN

Fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) with short capillary longitudinally packed with fine fibers as extraction device allows direct coupling to high performance liquid chromatography (HPLC) systems to determine weakly volatile or thermally labile compounds. This technique associates the advantages of miniaturized and analytical on-line systems. Major achievements include the use of different capillaries (fused-silica, copper, stainless steel, polyetheretherketone (PEEK), or poly(tetrafluoroethylene) (PTFE)) that are packed with neat fibers (Zylon®, silk, or Kevlar 29®) or fibers (stainless steel, basalt, or carbon) functionalized with selective coatings (aerogels, ionic liquids (ILs), polymeric ionic liquids (PILs), molecularly imprinted polymers (MIPs), layered double hydroxides (LDHs), or conducting polymer). This review outlines the fundamental theory and the innovative extraction materials for fiber-in-tube SPME-HPLC systems and highlights their main applications in environmental and bioanalyses.

12.
J Sep Sci ; 44(8): 1662-1693, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33528909

RESUMEN

In-tube solid-phase microextraction with a capillary column as extraction device can be directly coupled with high-performance liquid chromatography systems (HPLC). The in-tube solid-phase microextraction technique has been continuously developed since it was introduced in 1997. New couplings have also been evaluated on the basis of state-of-the-art HPLC instruments. Different types of capillaries (wall-coated open tubular, porous layer open tubular, sorbent-packed, porous monolithic rods, or fiber-packed) with selective stationary phases (monoliths, magnetic nanoparticles, conducting polymers, restricted access materials, ionic liquids, carbon, deep eutectic solvents, and hybrid materials) have been developed to boost in-tube solid-phase microextraction performance (sorption capacity and selectivity). This technique has been successfully applied to analyze biological samples (serum, plasma, whole blood, hair, urine, milk, skin, and saliva) for therapeutic drug monitoring, to study biomarkers, to detect illicit drugs, to conduct metabolomics studies, and to assess exposure to drugs. This review describes current advances in in-tube solid-phase microextraction extraction devices and their application in bioanalysis.


Asunto(s)
Carbono/química , Líquidos Iónicos/química , Microextracción en Fase Sólida , Cromatografía Líquida de Alta Presión , Tamaño de la Partícula , Porosidad , Solventes/química , Propiedades de Superficie
13.
J Sep Sci ; 44(8): 1621-1632, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33387419

RESUMEN

This manuscript describes the development of an innovative method to determine cannabinoids (cannabidiol and tetrahydrocannabinol) in human plasma samples by pipette tip micro-solid phase extraction and liquid chromatography-mass spectrometry/mass spectromtery. An octyl-functionalized hybrid silica monolith, which had been synthesized and characterized, was used as a selective stationary phase. The octyl-functionalized hybrid silica monoliths presented high permeability and adequate mechanical strength. The micro-solid phase extraction variables (sample pH, draw-eject cycles, solvent for phase clean-up, and desorption conditions) were investigated to improve not only the selectivity but also the sorption capacity. The method was linear at concentrations ranging from the lower limit of quantification (10.00 ng/mL) to the upper limit of quantification (150.0 ng/mL). The lack of fit and homoscedasticity tests, as well as the determination coefficients (r2 greater than 0.995), certified that linearity was adequate. The precision assays presented coefficient of variation values lower than 15%, and the accuracy tests provided relative error values ranging from 3.2 to 14%. Neither significant carry-over nor matrix effects were detected. Therefore, the pipette tip micro-solid phase extraction/liquid chromatography-mass spectrometry/mass spectrometry method has demonstrated to be adequate to determine cannabidiol and tetrahydrocannabinol simultaneously in plasma samples for therapeutic drug monitoring of patients undergoing treatment with cannabinoids.


Asunto(s)
Cannabidiol/sangre , Dronabinol/sangre , Dióxido de Silicio/química , Microextracción en Fase Sólida , Cromatografía Líquida de Alta Presión , Humanos , Tamaño de la Partícula , Propiedades de Superficie , Espectrometría de Masas en Tándem
14.
J Chromatogr A ; 1636: 461766, 2021 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-33316562

RESUMEN

To evaluate the endocannabinoid system in an animal model of Parkinson's disease, in-tube solid-phase microextraction (in-tube SPME) was directly coupled to a tandem mass spectrometry (MS/MS) system for determination of the endocannabinoids anandamide (AEA) and 2-arachidonoylglycerol (2-AG) in rat brain samples. In-tube SPME-which consisted of a microtube of restricted access material (RAM) with a hydrophilic diol external surface and a hydrophobic octyl inner surface-efficiently excluded (up to 95%) macromolecules from the biological samples and selectively pre-concentrated the analytes. In-tube SPME parameters, such as sample volume, mobile phases, flow rate, and pre-concentration time, were evaluated to improve the extraction efficiency and throughput performance. The selectivity of the in-tube SPME and MS/MS (MRM mode) techniques allowed them to be directly coupled online, which dismissed the need for the chromatographic separation step. The in-tube SPME-MS/MS method was validated and shown to be linear from 6.0 to 30.0 ng mL-1 for AEA and from 10.0 to 100.0 ng mL-1 for 2-AG; the intra- and inter-assay accuracy and precision were lower than 15%. Parallelism between the calibration curves constructed in the matrix and aqueous solution confirmed that there was no matrix effect. The method allowed endogenous concentrations of AEA and 2-AG to be determined in rat brain striatum from unilaterally 6-hydroxydopamine-lesioned animals. The concentrations of these endocannabinoids in striatum ipsilateral and contralateral to the lesion differed significantly (p<0.001).


Asunto(s)
Ácidos Araquidónicos/análisis , Encéfalo/metabolismo , Endocannabinoides/análisis , Glicéridos/análisis , Alcamidas Poliinsaturadas/análisis , Espectrometría de Masas en Tándem/métodos , Animales , Ácidos Araquidónicos/aislamiento & purificación , Ácidos Araquidónicos/normas , Encéfalo/efectos de los fármacos , Calibración , Cromatografía Líquida de Alta Presión , Endocannabinoides/aislamiento & purificación , Endocannabinoides/normas , Glicéridos/aislamiento & purificación , Glicéridos/normas , Interacciones Hidrofóbicas e Hidrofílicas , Masculino , Oxidopamina/farmacología , Alcamidas Poliinsaturadas/aislamiento & purificación , Alcamidas Poliinsaturadas/normas , Ratas , Ratas Wistar , Microextracción en Fase Sólida , Espectrometría de Masas en Tándem/normas
15.
Artículo en Inglés | MEDLINE | ID: mdl-32882531

RESUMEN

A simple and reliable method was developed and validated to determine the endocannabinoids anandamide (AEA) and 2-arachidonoylglycerol (2-AG) in rat brain samples by micro salting-out assisted liquid-liquid extraction combined with ultra-high performance liquid chromatography tandem mass spectrometry (SALLLE/UHPLC-MS/MS). The SALLE parameters (brain homogenate volume, salting-out agent, salt concentration, salt solution volume, organic solvent, organic solvent volume, and centrifugation temperature) were optimized to improve sensitivity and selectivity of the method. The SALLE/UHPLC-MS/MS method presented linear ranges from 2.00 to 20.00 ng mL-1 for AEA and from 0.300 to 10.00 µg mL-1 for 2-AG, no significant matrix effect, and inter- and intra-assay precision and accuracy with CV and RSE values lower than 15%, respectively. This innovative method was successfully applied to determine AEA and 2-AG in brain hemispheres from a 6-OHDA animal model of Parkinson's disease (PD).


Asunto(s)
Ácidos Araquidónicos/análisis , Química Encefálica/fisiología , Endocannabinoides/análisis , Glicéridos/análisis , Extracción Líquido-Líquido/métodos , Alcamidas Poliinsaturadas/análisis , Animales , Ácidos Araquidónicos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Modelos Animales de Enfermedad , Endocannabinoides/aislamiento & purificación , Glicéridos/aislamiento & purificación , Límite de Detección , Modelos Lineales , Masculino , Enfermedad de Parkinson/metabolismo , Alcamidas Poliinsaturadas/aislamiento & purificación , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
16.
J Neural Transm (Vienna) ; 127(10): 1359-1367, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32797288

RESUMEN

Levodopa-induced dyskinesias (LID) in Parkinson's disease (PD) are frequent complications, and the endocannabinoid system has a role on its pathophysiology. To test the hypothesis that the functioning of the endocannabinoid system would be altered in PD and in LID by measuring plasma and CSF levels of α-N-arachidonoylethanolamine (AEA) and 2-arachidonoyl-glycerol (2-AG) in patients with PD with and without LID and in healthy controls. Blood and CSF samples were collected from 20 healthy controls, 23 patients with PD without LID, and 24 patients with PD with LID. The levels of AEA and 2-AG were measured using a highly sensitive column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method. When pooled together, patients with PD had lower plasma and CSF levels of 2-AG and higher CSF levels of AEA compared to healthy controls (Mann-Whitney statistics = 303.0, p = 0.02). Patients with PD without LID had lower CSF levels of 2-AG (Kruskal-Wallis statistics = 7.76, p = 0.02) and higher CSF levels of AEA levels than healthy controls (Kruskal-Wallis statistics = 8.81, p = 0.01). The findings suggest that the endocannabinoid system participates in the pathophysiology of PD symptoms, but its role in the pathophysiology of LID is still unclear.


Asunto(s)
Discinesia Inducida por Medicamentos , Enfermedad de Parkinson , Antiparkinsonianos/efectos adversos , Cromatografía Líquida de Alta Presión , Endocannabinoides , Humanos , Levodopa/efectos adversos , Enfermedad de Parkinson/tratamiento farmacológico
17.
Cannabis Cannabinoid Res ; 5(1): 89-98, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32322680

RESUMEN

Introduction: Recent studies have suggested that cannabidiol (CBD) could interconvert into Delta-8- and Delta-9- tetrahydrocannabinol. Materials and Methods: Thus, we tested the plasma samples of 120 healthy human subjects (60 male and 60 female), 60 in fasting and the other 60 under normal feeding conditions after acute administration of an oral solution containing CBD 300 mg. To do this, we developed a bioanalytical method to determine CBD and the presence of THC in plasma samples by Ultra-High Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry. Results: The results showed that THC was not detected in plasma after the administration of CBD, and those study participants did not present psychotomimetic effects. Conclusions: The findings presented here are consistent with previous evidence suggesting that the oral administration of CBD in a corn oil formulation is a safe route for the administration of the active substance without bioconversion to THC in humans.

18.
Anal Bioanal Chem ; 412(11): 2465-2475, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32025768

RESUMEN

This manuscript describes the development of the restricted access carbon nanotube (RACNT) as a selective stationary phase for microextraction by packed sorbent (MEPS) to determine antipsychotics (chlorpromazine, clozapine, olanzapine, and quetiapine) in untreated plasma samples from schizophrenic patients by ultra-high liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The synthesis was achieved by chemically covering commercial multi-walled carbon nanotubes with bovine serum albumin (BSA) to subsequently pack the material in a polyethylene conical tube (1000 µL). The RACNTs' sorbents were able to exclude about 97% of the plasma proteins, maintaining the same performance for about 100 assays. The MEPS variables (sample pH, draw-eject cycles, desorption and phase cleanup) were evaluated to improve sensibility and selectivity. The MEPS/UHPLC-MS/MS method was linear at concentrations ranging from the lower limit of quantification (10.0 ng mL-1) to the upper limit of quantification (200-700 ng mL-1) with coefficients of determinations higher than 0.99. The precision assays presented relative standard deviation (RSD) values lower than 13%, and the accuracy assays presented relative error (RE) values that ranged from - 8.01 to 11.53%. Neither significant matrix effects nor carryover was observed. The developed method was successfully applied to determine antipsychotics drugs for therapeutic drug monitoring of schizophrenic patients.


Asunto(s)
Antipsicóticos/sangre , Monitoreo de Drogas/métodos , Nanotubos de Carbono/química , Microextracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Antipsicóticos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Humanos , Límite de Detección , Esquizofrenia/tratamiento farmacológico
19.
Anal Chim Acta ; 1099: 145-154, 2020 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-31986271

RESUMEN

A selective and sensitive method that uses automated in-tube solid-phase microextraction coupled to ultra-performance liquid chromatography-tandem mass spectrometry (in-tube SPME/UHPLC-MS/MS) was developed to determine cannabidiol (CBD) and Δ9-tetrahydrocannabinol (Δ9-THC) in plasma samples. A new dummy molecularly imprinted monolithic capillary (MIP monolith) for in-tube SPME was prepared by in situ polymerization in a fused silica capillary; hydrogenated cannabidiol was employed as dummy template. Fourier Transform Infrared Spectroscopy (FTIR) confirmed that the synthesis reagents were incorporated into the polymer chain. On the basis of the microscopy images (scanning electron microscopy - SEM and transmission electron microscopy - TEM), the MIP monolithic phase presented larger pores than the non-imprinted monolithic phase (NIP monolith), as well as a skeleton comprising clusters consisting of microspheres. By optimizing the polymerization conditions, the MIP monolith specifically recognized CBD and Δ9-THC. The MIP monolith had CBD and Δ9-THC sorption capacity of 148.05 and 44.49 ng cm-3, respectively. The capillary was reused over fifty times without significant changes in its extraction efficiency. For both CBD and Δ9-THC, in-tube SPME/UHPLC-MS/MS presented linear range from 10 to 300 ng mL-1, precision with coefficient of variation (CV) values ranging from 0.2% to 19.1% (LLOQ), and accuracy with relative standard deviation (RSD) values spanning from -9.3% to 19.6% (LLOQ). The developed method was successfully applied to determine cannabinoid levels in plasma samples from volunteer patients in treatment with CBD.


Asunto(s)
Cannabinoides/sangre , Impresión Molecular , Microextracción en Fase Sólida , Adsorción , Cannabinoides/química , Cromatografía Líquida de Alta Presión , Humanos , Estructura Molecular , Tamaño de la Partícula , Propiedades de Superficie , Espectrometría de Masas en Tándem
20.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1130-1131: 121809, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31669634

RESUMEN

This work describes the development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry method that uses disposable pipette extraction (DPX-UHPLC-MS/MS) to determine the endocannabinoid anandamide (AEA) in cerebrospinal fluid samples (CSF). The DPX parameters sorption equilibrium time, sample volume, number of draw-eject cycles, washing solvent volume, and elution solvent volume were optimized by design of experiments (DOE) techniques. The simple DPX protocol proposed herein required a reduced amount of CSF sample and organic solvent. The DPX-UHPLC-MS/MS method presented linear range from 0.10 ng mL-1 (LLOQ) to 3.0 ng mL-1, inter- and intra-assay accuracy with EPR values varying from -8.2% to 9.6%, inter- and intra-assay precision with CV values ranging from 1.3% to 14.8% (except for the LLOQ), and no significant matrix effect. The innovative DPX-UHPLC-MS/MS method was successfully applied to determine AEA in CSF samples from Parkinson's disease (PD) patients and should therefore be used in clinical studies.


Asunto(s)
Ácidos Araquidónicos/líquido cefalorraquídeo , Cromatografía Líquida de Alta Presión/métodos , Endocannabinoides/líquido cefalorraquídeo , Alcamidas Poliinsaturadas/líquido cefalorraquídeo , Espectrometría de Masas en Tándem/métodos , Ácidos Araquidónicos/aislamiento & purificación , Endocannabinoides/aislamiento & purificación , Humanos , Modelos Lineales , Alcamidas Poliinsaturadas/aislamiento & purificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...