Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Curr Oncol ; 24(4): e333-e336, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28874904

RESUMEN

Hepatocellular carcinoma (hcc) arising from a hepatic adenoma is a rare phenomenon accounting for fewer than 5% of hcc cases; it seldom recurs after resection of the primary tumour. We report a case of extrahepatic metastasis of hcc arising from a hepatic adenoma that presented as a solitary sternal metastasis without any evidence of intrahepatic recurrence. Our patient was initially treated with radiation therapy and bland embolization, without response. Subsequently, the patient developed progressive disease while taking sorafenib. He later received chemotherapy with docetaxel and gemcitabine, with the development of multiple pulmonary and splenic nodules. However, he remained free of intrahepatic recurrence. To the best of our knowledge, this is the first case of extrahepatic metastasis of hcc arising from a hepatic adenoma without evidence of intrahepatic recurrence.

4.
Clin Rehabil ; 12(6): 497-505, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9869253

RESUMEN

OBJECTIVE: To compare the reliability of measurements of hip motions obtained with two instruments, an electronic inclinometer and a two-arm goniometer, and to investigate whether the two instruments, and different body positions, produce the same measurement data. METHODS: Maximal active and passive hip movements were measured simultaneously with both instruments, in nine subjects during 10 consecutive measurements at short intervals. RESULTS: Intra-observer variability was lower with the inclinometer in measurements of passive hip rotations. The two instruments showed equal intra-observer variability for hip movements in general. The inclinometer showed lower inter-observer variability in the measurements of active internal rotation. More rotational movement was measured with the two-arm goniometer; more extension and flexion with the inclinometer. Also, more rotational movement was found in the prone position compared to sitting and supine positions. CONCLUSIONS: The inclinometer is more reliable in measurements of hip rotation. For hip movements in general the two-arm goniometer is just as accurate when used by only one observer. The two instruments, and some positions, are not interchangeable during consecutive measurements.


Asunto(s)
Articulación de la Cadera/fisiología , Rango del Movimiento Articular/fisiología , Adulto , Diseño de Equipo , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...