Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 18(14): 14654-63, 2010 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-20639951

RESUMEN

We report statistical fluctuations for the transmissions of a series of photonic-crystal waveguides (PhCWs) that are supposedly identical and that only differ because of statistical structural fabrication-induced imperfections. For practical PhCW lengths offering tolerable -3dB attenuation with moderate group indices (n(g) approximately 60), the transmission spectra contains very narrow peaks (Q approximately 20,000) that vary from one waveguide to another. The physical origin of the peaks is explained by calculating the actual electromagnetic-field pattern inside the waveguide. The peaks that are observed in an intermediate regime between the ballistic and localization transports are responsible for a smearing of the local density of states, for a rapid broadening of the probability density function of the transmission, and bring a severe constraint on the effective use of slow light for on-chip optical information processing. The experimental results are quantitatively supported by theoretical results obtained with a coupled-Bloch-mode approach that takes into account multiple scattering and localization effects.

2.
Rev Sci Instrum ; 80(4): 043101, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19405645

RESUMEN

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of delta(sigma)=0.33 cm-1 (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to lambda=58 nm with an ultimate resolving power of 500,000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O2 (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth "white" beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

3.
Opt Express ; 15(24): 16090-6, 2007 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-19550897

RESUMEN

We experimentally demonstrate an ultra high Q/V nanocavity on SOI substrate. The design is based on modal adaptation within the cavity and allows to measure a quality factor of 58.000 for a modal volume of 0.6(lambda/n)(3) . This record Q/V value of 10(5) achieved for a structure standing on a physical substrate, rather than on membrane, is in very good agreement with theoretical predictions also shown. Based on these experimental results, we show that further refinements of the cavity design could lead to Q/V ratios close to 10(6).

4.
J Opt Soc Am A Opt Image Sci Vis ; 23(7): 1608-15, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16783423

RESUMEN

We present a semianalytical model that quantitatively predicts the scattering of light by a single subwavelength slit in a thick metal screen. In contrast to previous theoretical works related to the transmission properties of the slit, the analysis emphasizes the generation of surface plasmons at the slit apertures. The model relies on a two-stage scattering mechanism, a purely geometric diffraction problem in the immediate vicinity of the slit aperture followed by the launching of a bounded surface-plasmon wave on the flat interfaces surrounding the aperture. By comparison with a full electromagnetic treatment, the model is shown to provide accurate formulas for the plasmonic generation strength coefficients, even for metals with a low conductivity. Limitations are outlined for large slit widths (>lambda) or oblique incidence (>30 degrees ) when the slit is illuminated by a plane wave.

5.
Phys Rev Lett ; 95(26): 263902, 2005 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-16486354

RESUMEN

In this Letter, we study the scattering of light by a single subwavelength slit in a metal screen. In contrast with previous theoretical works, we provide a microscopic description of the scattering process by emphasizing the generation of surface plasmons at the slit apertures. The analysis is supported by a rigorous formalism based on a normal-mode-decomposition technique and by a semianalytical model that provides accurate formulas for the plasmonic generation strengths. The generation is shown to be fairly efficient for metals with a low conductivity, such as gold in the visible regime. Verification of the theory is also shown by comparison with recent experimental data [H. F. Schouten, Phys. Rev. Lett. 94, 053901 (2005)].

6.
Opt Lett ; 25(23): 1690-2, 2000 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-18066315

RESUMEN

Blazed-binary gratings for which a blazed effect with binary etches is achieved under normal incidence offer first-order diffraction efficiencies larger than those of blazed-échelette gratings in the resonance domain [Opt. Lett. 23 1081 (1998)]. We provide further insight into the behavior of blazed-binary gratings and show that they operate efficiently under symmetrical mounting and over a wide field-angle interval. These properties are illustrated with theoretical and experimental results obtained for an approximately 1000-line/mm grating at 633 nm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA