Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
J Clin Microbiol ; 38(6): 2210-4, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10834978

RESUMEN

A clinical evaluation of an automated quantitative PCR assay, the COBAS AMPLICOR HCV MONITOR test, version 2.0 (v2.0), was carried out to assess the performance of this test in comparison with that of the previous, manual version, the AMPLICOR HCV MONITOR test, and with that of nested PCR. Serial dilutions of serum samples infected with genotype 1b, 2a, or 3, as well as synthetic RNA transcripts and serum samples derived from 87 patients with chronic hepatitis C and infected with genotype 1a, 1b, 2a, 2b, 3a, 3b, 4, or 5, were analyzed to determine the ability of the system to efficiently quantify various hepatitis C virus (HCV) genotypes. These experiments showed that the COBAS AMPLICOR HCV MONITOR test, v2.0, has mean intra-assay, interassay, and interoperator coefficients of variation that range from 22 to 34.5% and a 3-logarithm dynamic range, which spans from 10(3) to 10(6) copies/ml. Compared to the previous, manual version of the test, the COBAS AMPLICOR HCV MONITOR test, v2.0, showed an improved efficacy for all genotypes, especially genotypes 2, 3, and 4, whose estimated concentrations were on average 1 logarithm higher. When used to monitor patients under treatment, however, both versions showed the same patterns of viremia, indicating that the COBAS AMPLICOR HCV MONITOR test, v2.0, and the AMPLICOR HCV MONITOR test were equally effective at detecting relative viremia changes in serial samples. As expected, the automated test was less sensitive than nested PCR; among specimens from a cohort of patients treated with interferon, nested PCR identified three more viremic specimens, which probably contained very low concentrations of HCV RNA.


Asunto(s)
Hepatitis C Crónica/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Hepacivirus/genética , Hepatitis C Crónica/sangre , Humanos , Reacción en Cadena de la Polimerasa , ARN Viral/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Carga Viral
3.
J Virol Methods ; 74(2): 155-65, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9779615

RESUMEN

Viral load has emerged recently as a reliable marker of disease progression and therapeutic efficacy in chronic infections, including AIDS and hepatitis C. The clinical management of type B hepatitis could also be improved by monitoring viremia levels in patients with chronic liver disease undergoing anti-viral treatment. To address this question we evaluated the performance of a newly developed, quantitative PCR assay (Amplicor HBV Monitor test, Roche Diagnostic Systems) in the assessment of viremia changes over time in a group of 45 patients with chronic active hepatitis (CAH) who received interferon treatment. Of the 45 patients, 14 were HBsAg and anti-HBeAg positive and 31 HBsAg, HBeAg positive. Follow-up extended up to 24 months. An average of ten samples per patient were analyzed for levels of ALT, IgM anti-HBc (Abbott Laboratories), HBV DNA by in-house dot-blot hybridization and hybridization-capture assays (HBV-DNA hybrid capture kit, Murex Diagnostics) and by Amplicor HBV Monitor. A sustained biochemical response was observed at the end of treatment in 12 HBeAg-positive and in seven anti-HBeAg positive patients. This was accompanied by the disappearance of HBeAg and of HBV DNA (hybridization assays) in all cases and by the clearance of IgM anti-HBc in 70% of the cases. Viremia (quantitative PCR assay) became undetectable only in 25-30% of cases and was associated with the loss of HBsAg. A good correlation was observed between the time course of IgM anti-HBc, quantitative PCR and dot-blot hybridization although the latter missed 33% of viremic samples. Together, these results indicate that the Amplicor HBV Monitor test is a robust and standardized assay for quantifying HBV viremia levels in the range from 10(2) to 10(7) copies/ml. Compared to other current markers, viral load may provide additional clinical information by predicting long term virologic response and HBsAg clearance in patients with normal ALT at the end of interferon therapy.


Asunto(s)
Virus de la Hepatitis B/aislamiento & purificación , Hepatitis B Crónica/terapia , Hepatitis B Crónica/virología , Interferón-alfa/uso terapéutico , Reacción en Cadena de la Polimerasa/métodos , Viremia/virología , Adulto , Alanina Transaminasa/sangre , ADN Viral/sangre , Estudios de Evaluación como Asunto , Femenino , Anticuerpos contra la Hepatitis B/sangre , Antígenos de Superficie de la Hepatitis B/sangre , Antígenos e de la Hepatitis B/sangre , Virus de la Hepatitis B/genética , Humanos , Immunoblotting , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Carga Viral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...