1.
IEEE Trans Biomed Circuits Syst ; 17(4): 872-884, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37725736

RESUMEN

The key challenges in designing a multi-channel biosignal acquisition system for an ambulatory or invasive medical application with a high channel count are reducing the power consumption, area consumption and the outgoing wire count. This article proposes a spread-spectrum modulated biosignal acquisition system using a shared amplifier and an analog-to-digital converter (ADC). We propose a design method to optimize a recording system for a given application based on the required SNR performance, number of inputs, and area. The proposed method is tested and validated on real pre-recorded atrial electrograms and achieves an average percentage root-mean-square difference (PRD) performance of 2.65% and 3.02% for sinus rhythm (SR) and atrial fibrillation (AF), respectively by using pseudo-random binary-sequence (PRBS) codes with a code-length of 511, for 16 inputs. We implement a 4-input spread-spectrum analog front-end in a 0.18 µm CMOS process to demonstrate the proposed approach. The analog front-end consists of a shared amplifier, a 2nd order Σ∆ ADC sampled at 7.8 MHz, used for digitization, and an on-chip 7-bit PRBS generator. It achieves a number-of-inputs to outgoing-wire ratio of 4:1 while consuming 23 µA/input including biasing from a 1.8 V power supply and 0.067 mm2 in area.


Asunto(s)
Amplificadores Electrónicos , Suministros de Energía Eléctrica , Diseño de Equipo
2.
IEEE Trans Biomed Circuits Syst ; 12(3): 483-494, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29877813

RESUMEN

Cardiac signal acquisition with high linearity and accuracy of the high-pass cut-off frequency imposes a challenge on the implementation of the analog preprocessing and the analog-to-digital converter. This paper describes a state-space-based methodology for designing high-pass sigma-delta (HP) topologies with high linearity, targeting high accuracy of the high-pass cut-off frequency. Intermediate functions are evaluated mathematically to compare the proposed HP topologies with respect to dynamic range. A sensitivity performance analysis of the noise transfer function with respect to integrator nonidealities and coefficient variations is also described. Finally, to illustrate the design approach, an orthonormal HP modulator is designed to be implemented in 0.18 m CMOS technology, is tested with real prerecorded ECG signals.


Asunto(s)
Electrocardiografía , Procesamiento de Señales Asistido por Computador/instrumentación , Relación Señal-Ruido , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Humanos