Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Saudi J Gastroenterol ; 20(6): 360-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25434317

RESUMEN

BACKGROUND/AIM: There are currently no data on the relative retention rates of the Instinct clip, Resolution clip, and QuickClip2Long. Also, it is unknown whether retention rate differs when clips are applied to ulcerated rather than normal mucosa. The aim of this study is to compare the retention rates of three commonly used endoscopic clips. MATERIALS AND METHODS: Six pigs underwent upper endoscopy with placement of one of each of the three types of clips on normal mucosa in the gastric body. Three mucosal resections were also performed to create "ulcers." Each ulcer was closed with placement of one of the three different clips. Repeat endoscopy was performed weekly for up to 4 weeks. RESULTS: Only the Instinct and Resolution clips remained attached for the duration of the study (4 weeks). At each time point, a greater proportion of Instinct clips were retained on normal mucosa, followed by Resolution clips. QuickClip2Long had the lowest retention rate on normal mucosa. Similar retention rates of Instinct clips and Resolution clips were seen on simulated ulcers, although both were superior to QuickClip2Long. However, the difference did not reach statistical significance. All QuickClip2Long clips were dislodged at 4 weeks in both the groups. CONCLUSIONS: The Resolution and Instinct clips have comparable retention rates and both appeared to be better than the QuickClip2Long on normal mucosa-simulated ulcers; however this did not reach statistical significance. Both the Resolution clip and the Instinct clip may be preferred in clinical situations when long-term clip attachment is required, including marking of tumors for radiotherapy and anchoring feeding tubes or stents. Either of the currently available clips may be suitable for closure of iatrogenic mucosal defects without features of chronicity.


Asunto(s)
Endoscopía Gastrointestinal/instrumentación , Mucosa Gástrica/cirugía , Hemorragia Gastrointestinal/prevención & control , Hemorragia Posoperatoria/prevención & control , Úlcera Gástrica/cirugía , Instrumentos Quirúrgicos , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Mucosa Gástrica/patología , Estudios Prospectivos , Úlcera Gástrica/patología , Porcinos
2.
Eplasty ; 11: e42, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22096614

RESUMEN

OBJECTIVE: Manipulation of cotton operating room towels within the abdominal cavity in open abdominal surgery has been associated with the formation of peritoneal adhesions. In a rabbit model, the use of standard cotton operating room towels is compared to the Lap Pak, a silicone bowel-packing device, to determine the potential for reducing the risk of adhesions. METHODS: Thirty rabbits were randomly assigned to 3 groups. The rabbits underwent a sham surgery with incision only (n = 10), placement of operating room towels (n = 10), or placement of a Lap Pak (n = 10). After 14 days, the rabbits were sacrificed and the peritoneal cavity explored for adhesions. The number, tenacity, ease of dissection, and density of adhesions were recorded, and the adhesions quantitatively graded using a Modified Hopkins Adhesion scoring system. RESULTS: The operating room towel group had an average adhesion score of 2.5, and 8 (80%) rabbits developed adhesions. The sham group had an average adhesion score of 0.3 and one rabbit (10%) developed adhesions. The Lap Pak group had an average adhesion score of 0.2 and 1 rabbit (10%) developed adhesions. The frequency and severity of adhesions in the operating room towel group were significantly greater from that of the baseline sham group. There was no significant difference between the Lap Pak and sham groups. CONCLUSIONS: In this rabbit laparotomy model, the use of the Lap Pak to retract the bowels resulted in significantly fewer adhesions compared to cotton operating room towels. Lap Pak may be beneficial for bowel packing in general abdominal surgeries.

3.
Comp Med ; 59(1): 78-82, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19295057

RESUMEN

The causes and treatments of pancreatitis have been studied in diverse species, but the canine pancreatitis model has been used most often due to its similarities to the condition in humans. Although pancreatitis in dogs can be induced readily by numerous methods, managing these dogs can be difficult because they often develop severe abdominal pain, vomiting, inappetance, and lethargy. In an effort to study pancreatitis, we performed a pilot study to determine whether an endoscopic pancreatic procedure would be possible in a dog and whether, through various manipulations, a new method of inducing pancreatitis could be developed. The model uses endoscopic retrograde cholangiopancreatography (ERCP), a common procedure in human gastroenterology that has been associated with postprocedural pancreatitis. Although all 8 dogs used in developing the ERCP model had both biochemical and histologic changes consistent with pancreatitis, 7 of the 8 dogs remained free of classic clinical signs of the disease. This method is presented as a refinement of a canine model and presents an alternative method of inducing pancreatitis, with decreased risk of developing associated clinical signs.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Páncreas/patología , Pancreatitis/etiología , Pancreatitis/patología , Enfermedad Aguda , Amilasas/sangre , Animales , Modelos Animales de Enfermedad , Perros , Fluoroscopía , Lipasa/sangre , Masculino , Pancreatitis/sangre , Proyectos Piloto , Complicaciones Posoperatorias
4.
JOP ; 9(4): 456-67, 2008 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-18648137

RESUMEN

CONTEXT: The incidence of post-ERCP pancreatitis is 1-22%. It continues to be a difficult problem for endoscopist and patient. Uncovering an agent that may be used to prevent its occurrence is critical. OBJECTIVE: The aim of our study was to investigate the role of etanercept in the prevention of post-ERCP pancreatitis. DESIGN: Endoscopic retrograde pancreatography (ERP)-induced injury was performed in dogs using a previously established endoscopic model of post-ERCP pancreatitis. ANIMALS: Eight study dogs underwent ERP: 4 were pre-treated with etanercept one day before the procedure and 4 were untreated. In addition, three control dogs not undergoing ERP were also studied. MAIN OUTCOME MEASURES: Serum levels of amylase, lipase, and TNF-alpha, as well as the ratio of urinary trypsinogen activation peptide (TAP) and urinary creatinine, were measured before and after ERP. Necropsy was performed on post-operative day 5. All pancreatic specimens were graded by two blinded pathologists according to a validated scoring system. RESULTS: Eight study dogs developed mild to moderate clinical pancreatitis with hyperamylasemia (11,538+/-4,065 U/L vs. 701+/-157 U/L; post-ERP peak levels vs. baseline values: P<0.001) and hyperlipasemia (3,637+/-2,333 U/L vs. 246+/-125 U/L; P=0.003). Mean total injury score was significantly elevated in study dogs compared to control dogs (6.16+/-1.85 vs. 1.06+/-0.49; P=0.001). There were escalating total injury scores concordant with more elaborate methods of endoscopically-induced injury although the trend did not reach the statistical significance (P=0.223). When comparing untreated to etanercept-treated dogs, there were no significant differences in serum amylase levels (P=0.903), serum lipase levels (P=0.771), TAP/creatinine urinary ratio (P=0.912), and pancreatic injury score (P=0.324). CONCLUSION: Etanercept is ineffective in prevention of mild to moderate post-ERCP pancreatitis in canines. ERP-induced pancreatic injury can be used as a reliable animal model for studies investigating therapy and prevention of post-ERCP pancreatitis.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Inmunoglobulina G/uso terapéutico , Pancreatitis/prevención & control , Receptores del Factor de Necrosis Tumoral/uso terapéutico , Amilasas/sangre , Animales , Colangiopancreatografia Retrógrada Endoscópica/métodos , Modelos Animales de Enfermedad , Perros , Etanercept , Lipasa/sangre , Oligopéptidos/orina , Páncreas/patología , Pancreatitis/sangre , Pancreatitis/etiología , Insuficiencia del Tratamiento , Factor de Necrosis Tumoral alfa/sangre
5.
J Med Primatol ; 37 Suppl 1: 65-73, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18269532

RESUMEN

INTRODUCTION: Macaques are a commonly used non-human primate (NHP) model to evaluate safety and efficacy of topically applied vaginal microbicides. Cervicovaginal evaluation for topical microbicide safety studies requires proper technique, equipment, supplies, and sequence of sample collection. MATERIALS AND METHODS: Eleven rhesus macaques received a comprehensive sequential cervicovaginal examination under sedation before treatment and 24 hours post-instillation of test material. Examination was initiated with colposcopy, followed by diagnostics including vaginal culture, pH determination, cervicovaginal lavage, and cervicovaginal biopsy. RESULTS: Overall, the methods performed yielded samples that were appropriate for diagnostic evaluation and interpretation, and the macaques experienced minimal discomfort and complications. DISCUSSION: This paper provides a descriptive summary of compiled techniques required to conduct a safety evaluation for topically applied vaginal microbicides. This novel method-based approach should be methodically executed when evaluating a vaginally-applied, topical microbicide candidate.


Asunto(s)
Antiinfecciosos/administración & dosificación , Antiinfecciosos/efectos adversos , Cuello del Útero/efectos de los fármacos , Macaca mulatta , Modelos Animales , Vagina/efectos de los fármacos , Administración Intravaginal , Animales , Bacterias/aislamiento & purificación , Biopsia/instrumentación , Biopsia/veterinaria , Cuello del Útero/microbiología , Colposcopía/veterinaria , Femenino , Concentración de Iones de Hidrógeno , Irrigación Terapéutica , Vagina/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...