Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
ASAIO J ; 39(3): M363-7, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8268560

RESUMEN

The effect of pulsatile blood flow on platelet thrombogenicity and platelet fragmentation (PF) in a hollow fiber hemodialyzer (HFD) was quantified with 111In labeled platelets and 125I labeled fibrinogen; 150 ml of blood was collected from Beagle dogs, Yorkshire pigs, and a human volunteer (non-smoker). Platelets were labeled with 111In tropolone (300 microCi) and fibrinogen was labeled with 125I. Sham dialysis (SHD) was performed with 120 HFDs (0.9 meter2) at 37 degrees C, with flow-rates of 150, 250, 500, and 950 ml/min.; after SHD, the washed HD radioactivity was measured with an ionization chamber. PF was measured by flow cytometry with GP IIb-IIIa murine monoclonal antibody. Platelet deposition decreased significantly for 3 species at higher flow; fibrinogen deposition (10-12%, 55-65 mg/m2), was not affected by flow. Adherent platelet thrombus decreased from (8.2 +/- 3.4) to (3.1 +/- 1.0) with human blood as flow rate increased from 150 to 950 ml/min; platelet thrombus level also decreased significantly (p < 0.005) from (20.3 +/- 6.2) to (4.5 +/- 1.9) with canine blood. Higher values were obtained for canine than human and porcine platelets. Platelet fragmentation, on the other hand, increased from 2.1-2.2% to 10.2-11.3% with increase of flow. Like platelets, deposition of canine fibrinogen was slightly higher than that of pig and human. The studies of adherent thrombus and platelet fragmentation identified an important flow-window of reduced thrombogenicity and acceptable fragmentation, encouraging extracorporeal circulation at higher blood flow.


Asunto(s)
Fibrinógeno/metabolismo , Riñones Artificiales , Agregación Plaquetaria/fisiología , Tromboembolia/sangre , Animales , Velocidad del Flujo Sanguíneo/fisiología , Perros , Citometría de Flujo , Humanos , Radioisótopos de Indio , Radioisótopos de Yodo , Cinética , Membranas Artificiales , Modelos Cardiovasculares , Porcinos , Tromboembolia/prevención & control
2.
Nucl Med Biol ; 20(5): 579-87, 1993 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8358343

RESUMEN

The platelet thrombogenicity of a hemodialyzer was quantified with 99mTc- and 111In-labeled platelets. The platelets collected from blood of Beagle dogs, Yorkshire pigs and human volunteers were labeled with 111In-tropolone (detergent-free) and 99mTc-HMPAO. Hemodialysis was performed with a hollow-fiber dialyzer (HFD) in a flow-loop, the temperature of which was maintained at 37 degrees C, with flow-rates of 7, 150 and 270 mL/min; after dialysis, the HFD radioactivity was measured with an ionization chamber and imaged with a gamma-camera. The radioactivity of samples of hollow-fibers taken from the top, middle and bottom of the dialyzer was determined with a gamma-counter. The mean values of hemodialyzer-adherent platelet radioactivity were calculated for both radionuclides. The canine platelets were found to be more thrombogenic than porcine and human platelets. The adhesivity of porcine platelets to the biomaterial (cellulose-acetate) of the dialyzer approximated that of human platelets. The 99mTc label underestimated the thrombus formation (P < 0.01). The dynamic processes of thrombosis and embolization from the hemodialyzer resulted in the large standard deviations around the mean values of the adherent thrombus. In spite of this limitation of the dynamic pathology, the quantitation of comparative thrombogenicity with 111In- and 99mTc-labeled platelets suggests that both radionuclides could be used for measurement of device-induced thrombogenicity and may provide an estimation of prosthesis-induced thrombogenicity of human platelets from animal studies.


Asunto(s)
Plaquetas , Radioisótopos de Indio/efectos adversos , Compuestos de Organotecnecio/efectos adversos , Oximas/efectos adversos , Diálisis Renal/efectos adversos , Trombosis/etiología , Tropolona/efectos adversos , Animales , Perros , Humanos , Diálisis Renal/instrumentación , Especificidad de la Especie , Porcinos , Exametazima de Tecnecio Tc 99m
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA