Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Comput Biol Med ; 118: 103471, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31610882

RESUMEN

Stagnation of contents at the anastomotic site for intestinal flows after anastomotic operation is a critical issue in neonates. Although various anastomosis methods have been developed, in the clinical field, poor passage at the anastomotic site in cases of jejunal atresia is still observed. A CFD study was carried out to clarify the reasons for the stagnation and to find favorable anastomosis methods from a fluid dynamical point of view. Direct numerical simulations were performed using OpenFOAM. The boundaries of the computational domain were peristaltically moved to reproduce flow. The results reveal that the peristaltic motion on the distal side dominates the flow and that on the proximal side has a negligible influence. In particular, the contents do not pass the anastomotic site when the peristaltic motion on the distal side is not active. The flow rate as a measure of the driving force of the flow on the proximal side is large when the amplitude of the peristaltic motion is large and the diameter is small. It was also found that anastomosis methods do not affect flow resistance.


Asunto(s)
Hidrodinámica , Anastomosis Quirúrgica , Humanos , Recién Nacido
2.
Technol Health Care ; 25(5): 831-842, 2017 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-29103055

RESUMEN

BACKGROUND: Stent placement can change the hemodynamics in basilar artery aneurysms. However, the effects of the stent placement can depend on the angle of vessel bifurcation. OBJECTIVE: The hemodynamics in and near the aneurysm are investigated for two angles of vessel bifurcation and two stent models. Some statistical indexes are calculated to evaluate the effects of the stent placements on the possibility of aneurysm rupture. METHODS: Computational fluid dynamics simulations and phantom model experiments are performed. The angle between the basilar and posterior cerebral arteries is set to 90 and 135 degrees. The single stent and Y stent models are tested in addition to the case without stent placement. RESULTS: The velocity in the aneurysm in the Y stent case is smaller than that in the no stent and single stent cases when the angle is 135 degrees. High OSI and low AFI areas often appear at the same locations, and the area is larger in the single stent case than in the no stent and Y stent cases. CONCLUSIONS: The Y stent placement promotes hemostasis and thrombosis in the basilar artery aneurysm, whereas the single stent placement can enhance the growth and rupture.


Asunto(s)
Arteria Basilar/cirugía , Hemodinámica/fisiología , Aneurisma Intracraneal/cirugía , Arteria Cerebral Posterior/cirugía , Stents/normas , Trombosis/fisiopatología , Trombosis/cirugía , Humanos , Guías de Práctica Clínica como Asunto
3.
Med Biol Eng Comput ; 54(5): 831-41, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26438390

RESUMEN

This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent needs to be small enough to prevent blood flow into the aneurysm. Conventional flow-diverter stents are not available for stent-assisted coil embolization, which is an effective method for aneurysm occlusion, because the mesh size is too small to insert a micro-catheter for coil embolization. The proposed hybrid stent device is capable of stent-assisted coil embolization while simultaneously providing a flow-diverting effect. The fractal stent device is composed of mesh structures with fine and rough mesh areas. The rough mesh area can be used to insert a micro-catheter for stent-assisted coil embolization. Flow-diverting effects of two fractal stent designs were composed to three commercially available stent designs. Flow-diverting effects were analyzed using computational fluid dynamics (CFD) analysis and particle image velocimetry (PIV) experiment. Based on the CFD and PIV results, the fractal stent devices reduce the flow velocity inside an aneurism just as much as the commercially available flow-diverting stents while allowing stent-assisted coil embolization.


Asunto(s)
Embolización Terapéutica/instrumentación , Fractales , Hemorreología , Stents , Aneurisma/terapia , Prótesis Vascular , Simulación por Computador , Fantasmas de Imagen , Diseño de Prótesis , Flujo Pulsátil
4.
Circ J ; 70(1): 63-8, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16377926

RESUMEN

BACKGROUND: This study examined the effects of dual-chamber pacing (DDD) on regional myocardial deformation, as determined by echocardiographic strain and strain rate (SR) imaging, in patients with hypertrophic obstructive cardiomyopathy (HOCM). METHODS AND RESULTS: Fourteen patients (11 men, 3 women; mean age 55 +/-16 years) who had been on long-term DDD (mean period 7.4 +/- 2.1 years) underwent strain and SR imaging. Before and after DDD, the peak strain (%) and SR (s(-1)) during systole were assessed in 8 segments in 4 left ventricular (LV) walls. With DDD turned on, peak strain and SR were significantly increased in the basal anteroseptal (strain -10.2 +/- 6.8 to -1.0 +/- 6.4, p<0.005; SR -0.76 +/- 0.46 to 0.05 +/- 0.58, p<0.001) and septal segments (strain -11.2 +/- 8.9 to -2.2 +/- 7.7, p<0.005; SR -0.85 +/- 0.54 to -0.19 +/- 0.75, p<0.05), but not in the basal posterior (strain -15.0 +/- 13.0 to -13.4 +/- 9.2, p=NS; SR -1.37 +/- 0.57 to -1.93 +/- 0.65, p=NS) and lateral segments (strain -18.1 +/- 10.2 to -15.7 +/- 5.6, p=NS; SR -1.33 +/- 0.68 to -0.84 +/- 0.88, p=NS). These findings were associated with a modest, but significant, change in the LV pressure gradient (24 +/- 12 mmHg to 14 +/- 7 mmHg, p<0.001). CONCLUSIONS: In patients with HOCM, DDD appeared to produce myocardial lengthening in the basal septum during systole, which may have implications for the mechanism of reducing LV outflow obstruction during DDD.


Asunto(s)
Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/terapia , Corazón/fisiopatología , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Frecuencia Cardíaca , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Función Ventricular Izquierda
5.
Am J Cardiol ; 96(11): 1558-62, 2005 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-16310440

RESUMEN

Dual-chamber pacing reduces left ventricular (LV) outflow obstruction in patients with obstructive hypertrophic cardiomyopathy (HC), the mechanism of which lies in pacing-induced paradoxic septal motion. This study was conducted to test the hypothesis that tissue Doppler imaging (TDI) could demonstrate changes in the septal contraction sequence during dual-chamber pacing in patients with HC. TDI was performed in 16 patients (5 women; mean age 63+/-11 years) who underwent dual-chamber pacing for 7.6+/-2.1 year. With and without pacing, the time to peak systolic myocardial velocity was measured from the basal, mid, and distal segments in the 4 different LV walls. Without pacing, there was almost no longitudinal segmental asynchrony. During pacing, however, marked longitudinal segmental asynchrony appeared, especially in the anteroseptal wall (from p=NS to p<0.01 by analysis of variance) and the ventricular septum (from p<0.05 to p<0.01), with the time to peak velocity extremely prolonged at the distal segments. This was associated with a modest but significant decrease in the LV pressure gradient (from 20+/-8 to 14+/-7 mm Hg, p<0.01). In patients with obstructive HC, altered septal contraction sequence accounts for the reduced LV outflow obstruction during dual-chamber pacing, which was clearly demonstrated by TDI.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Tabiques Cardíacos/fisiopatología , Contracción Miocárdica/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo/fisiología , Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/terapia , Progresión de la Enfermedad , Ecocardiografía Doppler de Pulso , Femenino , Estudios de Seguimiento , Tabiques Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Presión Ventricular/fisiología
6.
Am J Cardiol ; 96(3): 408-11, 2005 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-16054469

RESUMEN

In patients with nonvalvular atrial fibrillation, the electrocardiographic fibrillatory wave reflects the structural and electrical remodeling of the atria. This study examined whether the fibrillatory wave amplitude could predict the risk of thromboembolism and demonstrated that this amplitude was related to the duration of atrial fibrillation. We also showed that the presence of fine fibrillatory waves (<1 mm in amplitude) could predict the thromboembolic potential in patients with chronic nonvalvular atrial fibrillation.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Tromboembolia/diagnóstico por imagen , Tromboembolia/fisiopatología , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Enfermedad Crónica , Ecocardiografía Doppler , Electrocardiografía , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Tromboembolia/epidemiología
7.
Circ J ; 68(5): 509-11, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15118299

RESUMEN

A 62-year-old female with palpitations was admitted to hospital where she recorded 12,299 monofocal ventricular premature contractions (VPCs) in 24 h and nonsustained ventricular tachycardia (VT) on exertion. She had hypokalemia with renal potassium wasting, a chloride-resistant metabolic alkalosis, elevated plasma renin, elevated plasma aldosterone (relative to the serum K concentration), hypomagnesemia with renal magnesium wasting, decreased urine calcium excretion, and normal blood pressure. The hypokalemia and hypomagnesemia were thought to have precipitated the VT. The coronary angiogram showed normal coronary arteries; however, the left ventriculogram revealed akinesis of the posterolateral wall. Because the VT could not be induced by programmed electrical stimulation either before or during intravenous administration of isoproterenol, the VPC with the same QRS morphology as the VT became the target of radiofrequency catheter ablation (RF-CA). Intracardiac mapping showed that the earliest activation site was situated in the asynergic area of the left ventricle (LV) and radiofrequency catheter ablation directed at the LV asynergy area completely eliminated the VPCs without any complications. During the follow-up period (6 months), she was free from palpitation and VT was not clinically documented.


Asunto(s)
Ablación por Catéter , Ejercicio Físico , Hipopotasemia/complicaciones , Deficiencia de Magnesio/complicaciones , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Ventriculografía con Radionúclidos , Síndrome , Taquicardia Ventricular/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA