Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Intervalo de año de publicación
1.
Braz J Cardiovasc Surg ; 36(4): 476-483, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34236815

RESUMEN

INTRODUCTION: Mitral valvuloplasty including ring/band support is widely performed despite potential drawbacks of rings. Unsupported valvuloplasty is performed in only a few centers. This study aimed to report long-term outcomes of patients undergoing unsupported valvuloplasty for degenerative mitral regurgitation (MR) and to identify predictive factors for outcomes. METHODS: This is a retrospective cohort including patients undergoing mitral valve repair for degenerative MR from 2000 to 2018. The main techniques were Wooler annuloplasty and quadrangular resection. Kaplan-Meier curves and Cox regression models were used for statistical analysis. RESULTS: One hundred fifty-eight patients were included (median age: 64.0 years). In-hospital mortality was 2.5%. Maximum followup was 19.6 years, with a median of 4.7 years (992 patient-years). Overall survival at 5, 10, and 15 years was 91.0% (95% confidence interval [CI]: 85.7-96.3), 87.6% (95% CI: 80.7-94.5), and 78.1% (95% CI: 65.9-90.3), respectively. The European System for Cardiac Operative Risk Evaluation (EuroSCORE) II was an independent predictor of late death (hazard ratio [HR] 1.42; P=0.016). Freedom from mitral reoperation at 5, 10, and 15 years was 88.1% (95% CI: 82.0-94.2), 82.4% (95% CI: 74.6-90.2), and 75.7% (95% CI: 64.1-87.3), respectively. Left atrial diameter > 56 mm was associated with late reintervention in univariate analysis (HR 1.06; P=0.049). CONCLUSION: Degenerative MR can be successfully treated with repair techniques without annular support, thus avoiding the technical and logistical drawbacks of ring/band implantation while maintaining good long-term results. EuroSCORE II was a risk factor for late death, and larger left atrium was associated with late reoperation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
2.
Pediatr Cardiol ; 37(7): 1319-27, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27335082

RESUMEN

Isolated congenital atrioventricular block (ICAVB) is a rare, and pacemaker implantation is the only effective treatment. We sought to identify the predictive factors of adverse events related to pacemaker implantation in ICAVB. This is a cohort study of patients diagnosed with ICAVB who underwent pacemaker implantation from 1980 to 2014 in a single center. During the studied period, a total of 647 patients underwent implantation of their first permanent cardiac pacemaker before 30 years of age. Of these, only 62 (9.5 %) were diagnosed with ICAVB. This condition was diagnosed in utero in 15 (24.2 %) cases, 5 (8.1 %) in the neonatal period, 32 (51.6 %) during childhood, and 10 (16.1 %) during adolescence and young adulthood. The presence of autoantibodies (anti-Ro/SSA) was observed in 41 % of mothers who underwent serological evaluation. Age at the time of the initial pacemaker implant was 9.8 ± 9 years. During a mean follow-up time of 15 years, 1 (1.7 %) death occurred due to infectious endocarditis. Complications related to pacemaker implant were reported in 24 patients (38.7 %). The number of complications was significantly higher in the group with an epimyocardial implantation site (HR 6; CI 2.45-14.95). Ventricular dysfunction occurred in 6 (11.7 %) patients; however, we were not able to identify any predictors of it. Our results showed a low mortality rate after permanent therapy. However, these patients exhibited high morbidity related to the pacemaker system, and the epimyocardial implant site was an independent predictor of complications. Predictors of left ventricular dysfunction were not found in the present study.


Asunto(s)
Marcapaso Artificial , Bloqueo Atrioventricular , Estudios de Cohortes , Humanos , Implantación de Prótesis , Resultado del Tratamiento , Disfunción Ventricular Izquierda
3.
Arq Bras Cardiol ; 88(2): 234-9, 2007 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-17384843

RESUMEN

OBJECTIVE: To evaluate the prognostic effect of aortic valve sclerosis on all-cause and cardiovascular mortality of patients seen at the Cardiology Institute of the Brazilian state of Rio Grande do Sul from 1996 to 2000. METHODS: A historical cohort study using information from both the database of the Echocardiography Laboratory of the Cardiology Hospital and the Death Registry of Rio Grande do Sul Health Department. The evaluation was carried out from 1996 to 2000. Study endpoints were all-cause and cardiovascular mortality. RESULTS: A total of 8585 patients were analyzed, 2154 (25%) of whom had aortic valve sclerosis. Mean follow-up was 41+/-6 months, and all-cause and cardiovascular deaths were 299 (3.5%) and 95 (1.1%), respectively. The group of patients with aortic valve sclerosis had more segmental cardiomyopathy, ventricular dysfunction, ventricular enlargement, and ventricular hypertrophy; yet, they did not show higher risk for all-cause or cardiovascular mortality in the multivariate analysis. CONCLUSION: The presence of aortic valve sclerosis was not associated with increased risk for all-cause and cardiovascular mortality in the population studied.


Asunto(s)
Válvula Aórtica/patología , Enfermedades Cardiovasculares/mortalidad , Anciano , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Métodos Epidemiológicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Esclerosis/diagnóstico por imagen , Esclerosis/mortalidad
4.
Arq. bras. cardiol ; Arq. bras. cardiol;88(2): 234-239, fev. 2007. tab
Artículo en Portugués | LILACS | ID: lil-444366

RESUMEN

OBJETIVO: Avaliar o efeito prognóstico da esclerose valvular aórtica na mortalidade e morte de causa cardíaca de pacientes atendidos no Instituto de Cardiologia do Rio Grande do Sul nos anos de 1996 a 2000. MÉTODOS: Estudo de coorte histórico que utilizou informações contidas nos bancos de dados do laboratório de ecocardiografia do Hospital de Cardiologia e nos Registros de Obitos da Secretária da Saúde do Rio Grande do Sul. O período de avaliação foi de 1996 a 2000. Os desfechos foram morte e morte de causa cardíaca. RESULTADOS: Foram analisados 8.585 casos, dos quais 2.154 (25 por cento) eram portadores de esclerose valvular aórtica. O tempo de seguimento médio foi de 41±6 meses, e a ocorrência de morte e morte cardíaca foram respectivamente, de 299 (3,5 por cento) e 95 (1,1 por cento). O grupo de pacientes com esclerose valvular aórtica apresentou mais miocardiopatia segmentar, disfunção ventricular, aumento ventricular e hipertrofia ventricular, e não apresentou, entretanto, maior risco de morte ou morte de causa cardíaca quando feita análise de multivariança. CONCLUSÃO: A presença de esclerose valvular aórtica não aumentou o risco de morte e de morte de causa cardíaca na população estudada.


OBJECTIVE: To evaluate the prognostic effect of aortic valve sclerosis on all-cause and cardiovascular mortality of patients seen at the Cardiology Institute of the Brazilian state of Rio Grande do Sul from 1996 to 2000. METHODS: A historical cohort study using information from both the database of the Echocardiography Laboratory of the Cardiology Hospital and the Death Registry of Rio Grande do Sul Health Department. The evaluation was carried out from 1996 to 2000. Study endpoints were all-cause and cardiovascular mortality. RESULTS: A total of 8585 patients were analyzed, 2154 (25 percent) of whom had aortic valve sclerosis. Mean follow-up was 41±6 months, and all-cause and cardiovascular deaths were 299 (3.5 percent) and 95 (1.1 percent), respectively. The group of patients with aortic valve sclerosis had more segmental cardiomyopathy, ventricular dysfunction, ventricular enlargement, and ventricular hypertrophy; yet, they did not show higher risk for all-cause or cardiovascular mortality in the multivariate analysis. CONCLUSION: The presence of aortic valve sclerosis was not associated with increased risk for all-cause and cardiovascular mortality in the population studied.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Válvula Aórtica/patología , Enfermedades Cardiovasculares/mortalidad , Válvula Aórtica , Brasil , Ecocardiografía , Métodos Epidemiológicos , Pronóstico , Esclerosis
5.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 18(4): 190-95, out.-dez. 2005. tab
Artículo en Portugués | LILACS | ID: lil-435867

RESUMEN

Recentemente, foram introduzidos no Brasil aparelhos implantáveis de estimulação cardíaca dotados de monitoramento transtelefônico, por meio do sistema Home Monitoring (Biotronik GMbH & Co. KG - Berlim, alemanha). A comercilaização desse sistema de telemonitoramento e sua possível difusão motivaram os autores a revisar os princípios éticos e legais relacionados à telemedicina e discutir alguns pontos específicos referentes ao uso desse recuros tecnológico. São apresentadas ainda algumas condutas para salvaguarda do médico consultor, responsável pelo recebimento e interpretaçao dos relatorios de monitoramento.


Asunto(s)
Humanos , Telemedicina/ética , Telemedicina/normas , Telemedicina
6.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 11(4): 186-190, out.-dez. 1998. ilus
Artículo en Portugués | LILACS | ID: lil-315295

RESUMEN

A estimulação bicameral utilizando um eletrodo flutuante único (modo VDD) pode ser indicada em pacientes com bloqueio atrioventricular (BAV) total e função sinusal normal, fundamentada na simplicidade oferecida pelo uso de apenas um eletrodo para obter o sincronismo AV. Contudo, subsistem dúvidas relativas à estabilidade tardia da função atrial e à efetividade do eletrodo em manter a leitura efetiva da onda P. Este estudo prospectivo visou a avaliação tardia da onda P sentida pelo eletrodo AV único em 40 pacientes que haviam implantado marcapasso VDD. O eletrodo fractal flutuante único SL60 Biotronik foi implantado por via transvenosa, teve a posição aferida por escopia. As medidas eletrofisiológicas revelaram onda P média de 2,4 Ý 1,0 mV, QRS médio de 11,0 Ý 3,8 mV e limiar de estimulação ventricular médio de 0,4 Ý 0,2 V. A programação padrão do gerador Dromos SL Biotronik foi mantida, com sensibilidade atrial de 0,2 mV. Após a alta hospitalar, os pacientes foram acompanhados periodicamente pelo clínico ou em ambulatório. A avaliação específica da amplitude mínima da onda P com o paciente na posição deitada ou sentada foi realizada em um período pós?implante que variou de 3 a 36 meses (média de 24 meses), com auxílio da telemetria do gerador. Durante o acompanhamento registrou-se perda do sinal e do comando atrial em 5 (12,5por cento) doentes. A reposição do eletrodo foi efetuada em 2 (5por cento ), a reprogramação da sensibilidade atrial em 2 (2,5por cento) e a reprogramação em modo VVI em 1 (2,5por cento) paciente. Quando da última revisão, 39 (97,5por cento) pacientes mostraram adequado sincronismo atrioventricular mediado pelo marcapasso. A avaliação tardia indicou média da onda P mínima de 1,6 Ý 1,4 mV em posição sentada e de 1,6 Ý 1,5 mV para os pacientes em pé, valores inferiores ao registrado no implante, mas superiores ao limiar de sensibilidade do marcapasso. Concluímos que o sistema de estimulação VDD com eletrodo fractal flutuante único é uma alternativa satisfatória para os pacientes com distúrbio de condução AV e atividade elétrica atrial normal. Seu emprego em pacientes com miocardiopatia severa ou que utilizem drogras antiarritmicas ou cronotrópico-negativas deve ser individualmente avaliado


Asunto(s)
Humanos , Estimulación Cardíaca Artificial , Marcapaso Artificial , Bloqueo Cardíaco/cirugía , Electrodos
7.
Artículo en Portugués | LILACS | ID: lil-220025

RESUMEN

Pacientes portadores de marcapasso cardíaco artificial por vezes necessitam submeter-se a procedimentos invasivos. Durante uma cirurgia geral, a situaçäo cardiovascular do paciente pode ser comprometida pela manutençäo de uma freqüência fixa ou pelo mau funcionamento do aparelho, resultante das interferências geradas por dispositivos como o eletrocautério ou o desfibrilador externo. Conseqüentemente, é necessário que a equipe médica que cuida do paciente tome cuidados específicos relativos à avaliaçäo pré-operatória, à monitorizaçäo e aos cuidados intra-operatórios (com ênfase na manutençäo da volemia adequada) e à aplicaçäo de dispositivos elétrico-eletrônicos capazes de interferir no funcionamento do marcapasso. No trasoperatório, o uso intermitente do eletrocautério bipolar, a aplicaçäo de um imä sobre o marcapasso ou, na necessidade de cardioversäo, o posicionamento das pás do desfibrilador distantes do gerador e da intreface eletrodo-coraçäo podem reduzir a incidência de complicaçöes.


Asunto(s)
Humanos , Fenómenos Fisiológicos Cardiovasculares , Cirugía General , Marcapaso Artificial , Cuidados Preoperatorios , Anestesia/estadística & datos numéricos , Cardioversión Eléctrica , Electrocoagulación , Monitoreo Intraoperatorio , Potasio/administración & dosificación
8.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 8(2): 85-92, maio-ago. 1995. ilus, tab
Artículo en Portugués | LILACS | ID: lil-266072

RESUMEN

A área de estimulaçäo cardíaca artificial permanente oferece um amplo campo para a pesquisa, que é empregada no desenvolvimento dos marcapassos, eletrodos e equipamento correlato, na avaliaçäo pré-operatória dos pacientes com arritmia, na cirurgia de implante dos marcapassos e na determinaçäo dos resultados imediatos e tardios deste procedimento. Os conhecimentos de eletrônica, biologia (fisiologia) e medicina necessários ao adequado manuseio dos pacientes podem impor dificuldades e resultados médicos insatisfatórios; um programa de pesquisa específico desenvolvido por Kirklin auxilia o marcapassista na obtençäo de melhor desempenho.


Asunto(s)
Humanos , Procedimientos Quirúrgicos Cardíacos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/mortalidad , Terapia por Estimulación Eléctrica , Estimulación Cardíaca Artificial/tendencias , Marcapaso Artificial/estadística & datos numéricos
9.
Rev. AMRIGS ; 38(3): 177-86, jul.-set. 1994. ilus, tab
Artículo en Portugués | LILACS | ID: lil-155231

RESUMEN

A pesquisa e uma investigacao, um registro e uma analise de evidencias visando aumentar o conhecimento humano. Usualmente e empregado pelos pesquisadores o metodo cientifico, que consiste basicamente de cinco etapas: l.sentido de dificuldade; 2.definicao do problema; 3. sugestao de solucao; 4. elaboracao de uma forma para evidenciar a solucao do problema; 5. verificacao experimental da hipotese. A cirurgia, uma especialidade medica que conjuga o conhecimento cientifico com a tecnica, tem utilizado a pesquisa pura e aplicada (experimental ou clinica) visando a melhores resultados. Com este objetivo, a pesquisa pode ser util visando desenvolver novas tecnicas cirurgicas, determinar resultados imediatos e tardios de um procedimento operatorio (expressos em termos de mortalidade, morbidade, sobrevida e melhora funcional) avaliar dispositivos proteticos implantaveis ou estudar casos excepcionais. Paralelamente ao ganho de coconhecimento, a investigacao pode auxiliar no desenvolvimento de habilidades perceptomotoras, no reconhecimento de resultados que um cirurgiao esta obtendo e na melhora de sua capacitacao profissional


Asunto(s)
Cirugía General , Investigación , Educación Médica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA