Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Thorac Cardiovasc Surg ; 58(5): 285-90, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20680905

RESUMEN

BACKGROUND: After cardioplegia, ischemia/reperfusion injury can induce apoptosis. The aim of this study was to evaluate our ex vivo microperfusion model on human myocardium during simulated cardioplegia (cp) and reperfusion (rep). In addition, the aim was to verify the anti-apoptotic properties of the phosphodiesterase 3 inhibitor milrinone. METHODS: Cardiac biopsies were retrieved from the right auricle of patients undergoing elective CABG prior to induction of cardiopulmonary bypass. Biopsies were exposed to ex vivo conditions with varying periods of cp/rep (30/10, 60/20, 120/40 min). Group I consisted of untreated controls (n=15), Group II of treated controls who had cp/rep (n=15) while Group III had cp/rep+milrinone (n=15). For the detection of apoptosis, anti-activated caspase-3 and PARP-1 cleavage immunostaining were used. RESULTS: The percentage of apoptotic cardiomyocytes in Group I was significantly (P<0.05) lower compared to Group II, revealing a time-dependent increase. In Group III with milrinone treatment, apoptosis was significantly suppressed (P<0.05). CONCLUSIONS: Milrinone significantly suppressed apoptosis in our ex vivo setting. This finding warrants further study aiming to evaluate the potential beneficial effects of milrinone on the suppression of ischemia/reperfusion injury in a clinical setting.


Asunto(s)
Apoptosis/efectos de los fármacos , Fosfodiesterasas de Nucleótidos Cíclicos Tipo 3/efectos de los fármacos , Circulación Extracorporea , Milrinona/farmacología , Daño por Reperfusión Miocárdica/prevención & control , Reperfusión Miocárdica/efectos adversos , Miocardio/patología , Inhibidores de Fosfodiesterasa/farmacología , Anciano , Biopsia , Caspasa 3/metabolismo , Femenino , Paro Cardíaco Inducido , Humanos , Inmunohistoquímica , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Daño por Reperfusión Miocárdica/etiología , Daño por Reperfusión Miocárdica/patología , Miocardio/enzimología , Perfusión , Proyectos Piloto , Poli(ADP-Ribosa) Polimerasa-1 , Poli(ADP-Ribosa) Polimerasas/metabolismo , Factores de Tiempo
3.
Rofo ; 180(5): 423-9, 2008 May.
Artículo en Alemán | MEDLINE | ID: mdl-18543415

RESUMEN

PURPOSE: The aim of the study was to assess the feasibility and additional diagnostic information of cardiac MRI as a supplement to state-of-the-art MR angiography (MRA) in the case of vascular risk patients. Therefore, the prevalence of delayed myocardial enhancement (DE) was determined in patients suffering from peripheral artery disease (PAD) and a clinical follow-up was evaluated after 2 years. MATERIALS AND METHOD: 87 consecutive patients (ages 66 +/- 10 years, 67 males) with symptomatic peripheral arterial occlusive disease (n = 68) or abdominal aortic aneurysm (n = 19) were examined using delayed cardiac enhancement (DE) within the clinical indication of MRA at a 1.5T system. A follow-up examination was carried out two years later (24 months +/- 4 months) with regards to cardiac events (cardiac death, myocardial infarction or acute coronary syndrome, heart insufficiency, coronary revascularization). RESULTS: In total, 40 / 87 patients had myocardial infarctions shown in MRI (46 %). In 25 patients (29 %), the myocardial infarction was already known, while in 15 patients (17 %) an occult progressing infarction was diagnosed (38 % of the myocardial infarcts). Follow-up data was able to be obtained after 2 years for 82 patients. 15 patients had a major cardiac event during the follow-up period, and 10 (67 %) of them already showed DE in the MRI. In the group with occult progressing infarctions, cardiac events occurred in 40 % (6 / 15 patients, cardiac death n = 1, ischemia n = 4, heart insufficiency n = 1, bypass n = 1), in patients with known infarction in 17 % (4 / 23 patients, cardiac death n = 1, ischemia n = 3, bypass n = 2) and in 11 % of patients without myocardial scars (5 / 44 patients, cardiac death n = 1, ischemia n = 2, heart insufficiency n = 2). CONCLUSION: Cardiac MRI in combination with MRA was feasible and showed a high prevalence of known and unexpected myocardial infarctions. This was of prognostic relevance in the follow-up 2 years later. Therefore, this enables important additional information regarding to the risk stratification and eventually targeted therapy in risk patients with PAD.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico , Arteriopatías Oclusivas/diagnóstico , Angiografía Coronaria , Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/mortalidad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/mortalidad , Arteriopatías Oclusivas/mortalidad , Comorbilidad , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Revascularización Miocárdica , Pronóstico , Sensibilidad y Especificidad , Análisis de Supervivencia
4.
Eur Radiol ; 17(11): 2948-56, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17929027

RESUMEN

The purpose was to assess 64-slice CT in the analysis of global and regional ventricular function, using a model of acute and subacute myocardial infarction in comparison with cine-MRI. Seven pigs underwent standard MSCT and MRI examination a median 1 and 21 days following creation of reperfused myocardial infarction. Endocardial and epicardial contours were manually defined and ventricular volumes calculated according to Simpson's method. Results were compared by Pearson's correlation coefficient and Blant-Altman analysis. Wall motion was assessed on cine-images and evaluated by kappa statistics. MSCT revealed a strong correlation with cine-MRI regarding quantification of end-diastolic volume (EDV; r = 0.97), end-systolic volume (ESV; r = 0.97), stroke volume (SV; r = 0.94), ejection fraction (EF; r = 0.95) or myocardial mass (MM; r =0.94 ). Minor overestimation was observed for EDV and ESV (bias -1.7 ml; -1.5 ml; P=0.095; 0.025), whilst the mean difference for EF was found to be negligible (bias 0.9%; P = 0.18). Both modalities showed a 96.2% segmental agreement in regional wall motion (weighted-kappa 0.91 for 238 segments). This was true for both acute and subacute infarct phase and MSCT, and thereby enabled accurate intraindividual follow-up of segmental dysfunction. Sixty-four-slice CT allows for reliable analysis of global cardiac function and, moreover, provides accurate evaluation of wall motion in acute and subacute myocardial infarct.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/patología , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Función Ventricular Izquierda , Enfermedad Aguda , Animales , Diástole , Corazón/diagnóstico por imagen , Modelos Estadísticos , Infarto del Miocardio/diagnóstico por imagen , Miocardio/patología , Porcinos , Sístole , Factores de Tiempo
5.
Rofo ; 179(10): 1009-15, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17879173

RESUMEN

PURPOSE: Mesenchymal stem cells (MSC) seem to be a promising cell source for cellular cardiomyoplasty. We recently developed a new aptamer-based specific selection of MSC to provide "ready to transplant" cells directly after isolation. We evaluated MRI tracking of newly isolated and freshly transplanted MSC in the heart using one short ex vivo selection step combining specific aptamer-based isolation and labeling of the cells. MATERIALS AND METHODS: Bone marrow (BM) was collected from healthy pigs. The animals were euthanized and the heart was placed in a perfusion model. During cold ischemia, immunomagnetic isolation of MSC from the BM by MSC-specific aptamers labeled with Dynabeads was performed within 2 h. For histological identification the cells were additionally stained with PKH26. Approx. 3 x 10(6) of the freshly aptamer-isolated cells were injected into the ramus interventricularis anterior (RIVA) and 5 x 10(5) cells were injected directly into myocardial tissue after damaging the respective area by freezing (cryo-scar). 3 x 10(6) of the aptamer-isolated cells were kept for further characterization (FACS and differentiation assays). 20 h after cell transplantation, MRI of the heart using a clinical 3.0 Tesla whole body scanner (Magnetom Trio, Siemens, Germany) was performed followed by histological examinations. RESULTS: The average yield of sorted cells from 120 ml BM was 7 x 10(6) cells. The cells were cultured and showed MSC-like properties. MRI showed reproducible artifacts within the RIVA-perfusion area and the cryo-scar with surprisingly excellent quality. The histological examination of the biopsies showed PKH26-positive cells within the areas which were positive in the MRI in contrast to the control biopsies. CONCLUSION: Immunomagnetic separation of MSC by specific aptamers linked to magnetic particles is feasible, effective and combines a specific separation and labeling technique to a "one stop shop" strategy.


Asunto(s)
Aptámeros de Nucleótidos , Cardiomioplastia , Imagen por Resonancia Magnética , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Animales , Células de la Médula Ósea , Cardiomioplastia/métodos , Separación Celular , Estudios de Factibilidad , Colorantes Fluorescentes , Separación Inmunomagnética , Células Madre Mesenquimatosas/citología , Isquemia Miocárdica , Compuestos Orgánicos , Coloración y Etiquetado , Porcinos , Factores de Tiempo
6.
Eur J Radiol ; 62(2): 235-46, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17187952

RESUMEN

OBJECTIVE: The aim of this study was to assess the accuracy of MSCT in characterizing myocardial infarction (MI) and, thereby, determine the extent of early perfusion defect (ED), microvascular obstruction (MO) and transmural depth of late enhancement (LE) in comparison to MRI and histology. MATERIALS AND METHODS: Seven pigs were studied with MSCT (Somatom Sensation 64) and MRI (Magnetom Sonata) a median 1 and 21 days following temporary occlusion of a diagonal branch and creation of small reperfused infarction. For depiction of ED, CT images were acquired in the early arterial phase and following 35 s; LE and MO were evaluated on images obtained at 3, 5, 10 and 15 min. Thereby, a bolus/low-flow contrast injection protocol was used. Triphenyltetrazolium-chloride (TTC) stain and histology were obtained. Volumes of enhancement patterns were assessed as percentage of the ventricle and compared by Bland-Altman analysis. Segmental co-localization and graded transmurality was evaluated with weighted-kappa-test. RESULTS: Close spatial agreement was observed for MRI-MO and MSCT-MO (bias=0.55; CI=-1.49 to 2.60 at 5 min MSCT), TTC and MSCT-LE (bias=-1.28; CI=-3.76 to 1.19) or MRI-LE and MSCT-LE (bias=-0.79; CI=-4.19 to 2.60). There was good segmental co-localization for MO (weighted kappa=0.93) and high agreement for transmural extent of TTC, MRI-LE and MSCT-LE (weighted kappa=0.84 TTC versus MSCT; 0.86 MRI versus MSCT). Arterial and 35s ED significantly underestimated infarct size and showed poor segmental or transmural agreement (weighted kappa=0.33; 0.44). CONCLUSIONS: MSCT late-scans not only reliably depict size of MO and LE in acute or subacute infarct phases but, moreover, allow for accurate determination of LE transmurality.


Asunto(s)
Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Tomografía Computarizada por Rayos X , Análisis de Varianza , Animales , Colorantes , Medios de Contraste , Modelos Animales de Enfermedad , Gadolinio DTPA , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Aumento de la Imagen , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Proyectos de Investigación , Sensibilidad y Especificidad , Porcinos , Sales de Tetrazolio
7.
Eur Radiol ; 17(2): 475-83, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16802125

RESUMEN

The purpose was to assess the practicability of low-dose CT imaging of late enhancement in acute infarction. Following temporary occlusion of the second diagonal branch, seven pigs were studied by multislice computed tomography (MSCT) and magnetic resonance imaging (MRI). Thus, 64-slice CT was performed at 3, 5, 10 and 15 min following the injection of contrast medium according to a bolus/low-flow protocol. Standard parameters of 120 kV and 800 mAs were compared with 80 kV and 400 mAs in various combinations. Infarct volumes were assessed as percentage of the ventricle for both MSCT and MR images. CT density values for viable and infarcted myocardium were obtained and image quality assessed. Mean infarct volume as measured by MRI was 12.33+/-7.06%. MSCT achieved best correlation of volumes at 5 and 10 min. Whilst lowering of tube current resulted in poor correlation, tube voltage did not affect accuracy of infarct measurement (r (2)=0.92 or 0.93 at 5 min, 800 mAs and 80 or 120 kV). In terms of image quality, greater image noise with 80 kV was compensated by significantly better contrast enhancement between viable and non-viable myocardium at lower voltage. Myocardial viability can accurately be assessed by MSCT at 80 kV, which ensures higher contrast for late enhancement and yields good correlation with MRI.


Asunto(s)
Medios de Contraste/administración & dosificación , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Daño por Reperfusión Miocárdica/patología , Tomografía Computarizada por Rayos X , Análisis de Varianza , Animales , Modelos Animales de Enfermedad , Electrocardiografía , Gadolinio DTPA/administración & dosificación , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Infarto del Miocardio/etiología , Daño por Reperfusión Miocárdica/complicaciones , Variaciones Dependientes del Observador , Dosis de Radiación , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Porcinos , Factores de Tiempo
8.
Thorac Cardiovasc Surg ; 54(7): 474-6, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17089315

RESUMEN

Stroke after cardiac surgery is a devastating complication. We report a case of incidental diagnosis of a left ventricular thrombus in a patient scheduled to undergo coronary artery bypass grafting. The preoperative diagnosis of an apical left ventricular thrombus was assessed by a novel, whole body MRI-angiography technique (TIMRA), which led to alteration of the operative approach as an additional thrombectomy was performed through an apical left ventriculotomy.


Asunto(s)
Puente de Arteria Coronaria , Cardiopatías/diagnóstico , Angiografía por Resonancia Magnética , Trombectomía/métodos , Trombosis/diagnóstico , Cardiopatías/cirugía , Ventrículos Cardíacos , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Trombosis/cirugía
9.
Rofo ; 178(5): 491-9, 2006 May.
Artículo en Alemán | MEDLINE | ID: mdl-16708323

RESUMEN

PURPOSE: To examine patients with peripheral-arterial-occlusive-disease (PAOD) for systemic effects associated with atherosclerosis using a comprehensive state-of-the-art whole-body MR examination protocol. The protocol comprises the assessment of the complete arterial vasculature (except coronary arteries), the brain, and the heart. MATERIALS AND METHODS: Multi-station whole-body 3D MR angiography was performed in sixty consecutive patients with clinical suspicion for PAOD at 1.5 T (Magnetom Avanto, Siemens, Erlangen, Germany). Functional and delayed enhancement cardiac images were acquired, as well as FLAIR images of the brain and TOF angiography of intracranial vessels. MR and DSA images were assessed by independent observers for atherosclerotic manifestations and other pathology. Sensitivity and specificity for the detection of vascular pathology was calculated for MR data using conventional DSA of the symptomatic region as standard-of-reference. RESULTS: Sensitivity and specificity for the detection of significant vascular stenosis (> 70 % luminal narrowing) was 94 % and 96 % (PPV 87 %, NPV 98 %). Significant microangiopathic tissue alterations (n = 7) and/or cerebral infarction (n = 18) were diagnosed in 23/60 patients. Thirty-eight of 60 patients presented with systolic left ventricular wall motion abnormalities. In 24 patients subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. CONCLUSION: For patients with PAOD and suspected systemic atherosclerotic disease a comprehensive diagnosis of accompanying cardiovascular pathology and therefore staging of systemic atherosclerotic disease is feasible within one MR examination.


Asunto(s)
Aterosclerosis/diagnóstico , Enfermedades Cardiovasculares/diagnóstico , Trastornos Cerebrovasculares/diagnóstico , Angiografía por Resonancia Magnética/métodos , Enfermedades Vasculares Periféricas/diagnóstico , Anciano , Angiografía de Substracción Digital , Aterosclerosis/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/diagnóstico por imagen , Protocolos Clínicos , Intervalos de Confianza , Interpretación Estadística de Datos , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Sensibilidad y Especificidad
10.
Ultraschall Med ; 27(2): 176-9, 2006 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-16612726

RESUMEN

We report on a 57-year-old male patient with typical claudication localised in the right thigh, following aortic valve replacement. The ankle brachial index under resting conditions is within normal range on both sides. A conspicuous monomorphic double-humped peripheral Doppler flow pattern with an early systolic notch extending to the baseline can be registered in all the arteries of the right lower limb. The flow patterns of all other peripheral arteries are properly configured and of triphasic morphology. As the underlying cause of the pathologically altered Doppler flow morphology, aortic dissection Type A can be detected, extending from the former cannulation site of the ascending aorta into the right common iliac artery. Its dissection membrane functionally occludes the right common iliac artery in the early systole, the effect being brief and reversible. The pathogenesis of this morphologically altered Doppler flow pattern and potential differential diagnoses are discussed in this case report, also considering the current literature.


Asunto(s)
Disección Aórtica/diagnóstico por imagen , Arteriopatías Oclusivas/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Diagnóstico Diferencial , Lateralidad Funcional , Humanos , Masculino , Persona de Mediana Edad , Arterias Tibiales/diagnóstico por imagen , Tomografía Computarizada por Rayos X
11.
Thorac Cardiovasc Surg ; 53(5): 267-73, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16208611

RESUMEN

BACKGROUND: After aortic valve-sparing procedures patients should be evaluated regularly because of the risk for further disease progression in the remaining aorta as well as recurrent aortic insufficiency. The purpose of this study was to evaluate the potential of functional MRI as a single examination for complete follow-up of these patients. METHODS: Twenty-two patients with a mean age of 54 years (range 30 - 66) were prospectively examined at 1, 12, 24, 36, and 74 months postoperatively, following a Yacoub aortic root remodeling operation, using a 1.5 T MRI. The original disease was chronic aneurysm of the ascending aorta or root in 17, chronic dissection in 3, and acute dissection in 2 patients. Transverse graft diameters, regurgitant fraction, LVEDV, and cardiac index were measured using cine MRI. Results were compared to spiral computed tomography and transthoracic color Doppler echocardiography. Mean time of follow-up was 24.9 months and ranged from 1 to 74 months. RESULTS: There were 2 re-operations, 2 years after primary surgery, due to high aortic insufficiency. CT and MRI measurements of graft diameters correlated well (p = 0.4544). Mean graft diameter (mean +/- SD) was 30 +/- 3.7, 33 +/- 3.4, 36.5 +/- 1.5, 37 +/- 2.8, and 38.3 +/- 2.8 mm at 1, 12, 24, 36, and 74 months, respectively, indicating a significant increase of graft diameter (p < 0.0001). Mean regurgitant fraction as determined by MRI was 14 +/- 7, 12 +/- 9, 13 +/- 9, 15 +/- 7, and 14 +/- 9 % at 1, 12, 24, 36, and 74 months, respectively. Flow based grading of aortic insufficiency by MR imaging correlated well with color Doppler echocardiography (p < 0.0001). CONCLUSIONS: MRI provides an excellent, noninvasive, comprehensive tool for follow-up after valve-sparing aortic root reconstruction. The determination of regurgitant fraction, ventricular dimensions and functions, and graft diameters allows standardized imaging protocols with a high reproducibility, which may lead to this technique being favored for the follow-up of patients after aortic root remodeling.


Asunto(s)
Aneurisma de la Aorta/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Disección Aórtica/diagnóstico , Disección Aórtica/fisiopatología , Disección Aórtica/cirugía , Aneurisma de la Aorta/fisiopatología , Aneurisma de la Aorta/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Ecocardiografía Doppler en Color , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Estadística como Asunto , Tomografía Computarizada Espiral , Resultado del Tratamiento
12.
Rofo ; 177(8): 1094-102, 2005 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-16021541

RESUMEN

PURPOSE: To evaluate graft patency, flow and flow reserve in patients with minimal invasive direct coronary artery bypass (MIDCAB) of internal mammary artery (IMA) grafts using a combined MR protocol with phase-contrast technique and MR angiography. MATERIAL AND METHODS: At a 1.5T Magnetom Sonata (SIEMENS), 19 symptomatic (angina CCS I-III, intermittent thoracic discomfort, scar disorders) patients (59.9 +/- 7.9 years old) with 19 left internal mammary artery (LIMA) grafts implanted in minimal invasive technique were examined 6.9 +/- 1.5 years post surgery. Contrast enhanced MR angiography (TR 2.5 ms, TE 1 ms, flip angle 20 (o), spatial resolution 1.4 x 0.9 x 1.0 mm(3), breath hold technique, no ECG-triggering, 25 ml Gd-DTPA) was performed to assess bypass patency. Phase-contrast flow measurements with retrospective gating (TR 41 msec, TE 3.2 msec, flip angle 30 degrees , spatial resolution 1.1 x 1.1 x 5 mm(3), temporal resolution 42 msec, venc 90 cm/sec) were applied in the IMA grafts at rest and after stress induction with dipyridamole (0.56 mg/kg/BW). For comparison, graft patency was evaluated by multidetector-row computed tomography (16-row CT). In 9 patients a selective catheter angiography was performed. RESULTS: MIDCAB grafts were occluded in 4/19 patients. In 4 patients the anastomosis to LAD was highly stenotic (> 70 %) at MDCT (2 experienced investigators in consensus reading). In MRA 9 grafts could be delineated completely including the distal anastomosis to LAD (47 %). In 9 patients the distal part could not be evaluated. In patients with patent grafts (MDCT), a significant improvement of graft flow (at rest 75.4 +/- 33.3 ml/min; after stress 202.7 +/- 49.6; P < 0.002) and flow reserve (patent grafts 3.0 +/- 1.1; stenotic grafts 1.5 +/- 0.2, P < 0.02; occluded grafts 0.9 +/- 0.2, P < 0.01) after stress induction was detected. Diastolic-to-systolic peak velocity ratios (D/S-PVR) at baseline were not significant between patent and stenotic grafts. Mean flow at baseline and after stress induction and flow reserve show a high sensitivity (91/92 /83 %) and specificity (86 /100/83 %) for detection of graft stenosis. MR angiography combined with flow reserve measurements could distinguish between occluded/stenotic and patent grafts in all MIDCAB grafts. CONCLUSION: MR imaging allows combined assessment of bypass patency and flow with flow reserve in patients after MIDCAB. The protocol of this study is applicable for the evaluation of graft patency in patients after revascularization.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Angiografía por Resonancia Magnética/métodos , Arterias Mamarias/patología , Arterias Mamarias/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Persona de Mediana Edad , Pronóstico , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
13.
Thorac Cardiovasc Surg ; 53(2): 80-4, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15786005

RESUMEN

OBJECTIVES: The serine-protease inhibitor aprotinin protects platelet function during cardiopulmonary bypass. However, its safety and efficacy during deep hypothermic circulatory arrest (DHCA) is controversial, and aprotinin is suspected to cause thrombosis especially during hypothermia. The platelet GP IIb/IIIa inhibitor eptifibatide has been assumed to preserve platelet function during cardiopulmonary bypass without increasing bleeding complications. The aim of this study was to compare the effect of aprotinin and eptifibatide on platelet function under conditions of DHCA. METHODS: Heparinized blood from healthy volunteers (n = 10) was incubated in stasis for 30 minutes at 18 degrees C to simulate DHCA and compared to samples incubated at 37 degrees C. The effect of eptifibatide (2.5 microg/ml) and aprotinin (300 KIU/ml) on platelets under these conditions was analyzed by flow cytometry. Platelet aggregates were identified using CD41-antibody binding and size. GPIIb/IIIa function was evaluated with the activation-specific antibody PAC-1 after stimulation with 10 microM ADP. Aggregate numbers and antibody mean-fluorescence are reported as mean +/- standard deviation. RESULTS: Hypothermia induced a 2.5-fold increase of aggregates ( p < 0.001) and a 2.6-fold increase of GPIIb/IIIa activation ( p < 0.001). This effect was not influenced by aprotinin but almost completely inhibited by eptifibatide ( p < 0.001). CONCLUSIONS: Aprotinin has no procoagulatory effect on platelet function during hypothermia but is not protective either. Eptifibatide inhibits hypothermia-induced platelet aggregation in vitro and may prevent aggregate sequestration in the microvasculature and consecutive ischemic organ damage in vivo.


Asunto(s)
Aprotinina/farmacología , Frío , Péptidos/farmacología , Inhibidores de Agregación Plaquetaria/farmacología , Agregación Plaquetaria/efectos de los fármacos , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Plaquetas/efectos de los fármacos , Recolección de Muestras de Sangre , Eptifibatida , Citometría de Flujo , Humanos , Hipotermia/sangre , Técnicas In Vitro , Masculino
14.
Br J Radiol ; 78(928): 292-8, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15774587

RESUMEN

The objective of this study was to evaluate graft flow (f) and patency (p) in patients with internal mammary artery (f,p) and venous (p only) grafts using a combined MR protocol with phase-contrast technique and MR angiography. 42 patients with 42 left internal mammary artery (LIMA) and 63 venous grafts were examined pre and 6 months post coronary artery bypass graft (CABG) surgery. Phase-contrast flow measurements were applied to the IMA. Post-operatively, a contrast enhanced MR angiogram was performed to assess bypass patency. LIMA/venous grafts were occluded in 3/42 and 13/63, respectively. Flow in LIMA decreased from 19.4+/-10.4 ml min(-1) m(-2) pre-operatively to 13.4+/-9.7 ml min(-1) m(-2) post-operatively (p<0.002). In contrast, flow in the native right IMA increased from 17.6+/-8.7 ml min(-1) m(-2) pre-operatively to 24.8+/-9.0 ml min(-1) m(-2) post-operatively (p<0.001). MRI allows a combined assessment of bypass patency and flow. This study protocol may be applicable to perioperative follow-up studies in patients after CABG surgery.


Asunto(s)
Puente de Arteria Coronaria/métodos , Cuidados Intraoperatorios/métodos , Grado de Desobstrucción Vascular , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Medios de Contraste , Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/cirugía , Femenino , Humanos , Anastomosis Interna Mamario-Coronaria/métodos , Angiografía por Resonancia Magnética/métodos , Masculino , Arterias Mamarias/fisiología , Persona de Mediana Edad , Grado de Desobstrucción Vascular/fisiología
15.
Rofo ; 173(9): 790-7, 2001 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-11582557

RESUMEN

PURPOSE: To evaluate LV functional parameters, graft flow and patency in patients with IMA grafts using a combined MR protocol with phase-contrast technique and contrast enhanced MR angiography. MATERIAL AND METHODS: Using a 1.5 T MR system 27 patients with 27 left internal mammary artery (LIMA) and 41 venous grafts were examined before and 6 months after CABG surgery. A T(1)w-TSE sequence (slice thickness 5 mm) was applied for morphological imaging. LV function (EF, CO) was evaluated on cine images (segmented FLASH 2D, TR(eff) 11 ms, TE 4.8 ms, flip angle 25 degrees ). A phase-contrast FLASH 2D (TR 24 ms, TE 5 ms, flip angle 20 degrees ) sequence was applied for aortic and IMA flow measurements. Postoperatively, a contrast enhanced FLASH 3D MR angiography (TR 3.8 ms, TE 1.4 ms, flip angle 30 degrees ) with 25 ml Gd-DTPA was performed to assess bypass patency. RESULTS: In patients with reduced LV function (ejection fraction < 50 %) an improvement of the ejection fraction from 38.4 +/- 10.3 % to 49.8 +/- 15.3 % (p < 0.05) was found postoperatively. LIMA grafts were occluded in 1/27 patients, while 6/41 venous grafts were occluded. Distal LIMA anastomoses were demonstrated in 33 % by MRA. Flow of LIMA decreased from 21.2 +/- 11 ml/min/m(2) preoperatively to 14.4 +/- 9.6 ml/min/m(2) postoperatively (p < 0.01). CONCLUSION: MR imaging allows accurate combined assessment of LV function, bypass patency and flow. The protocol of this study may be applicable for perioperative follow-up studies in patients after CABG surgery.


Asunto(s)
Puente de Arteria Coronaria , Oclusión de Injerto Vascular/diagnóstico , Aumento de la Imagen , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Revascularización Miocárdica , Complicaciones Posoperatorias/diagnóstico , Disfunción Ventricular Izquierda/diagnóstico , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Medios de Contraste , Femenino , Estudios de Seguimiento , Gadolinio DTPA , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Sensibilidad y Especificidad , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología
16.
Artículo en Inglés | MEDLINE | ID: mdl-11460993

RESUMEN

Approximately 5% of patients with transposition of the great arteries have a single coronary artery. In the early years of the arterial switch procedure a single coronary artery was associated with an increased risk of mortality. This was particularly true for the most common type of single coronary artery in which there is a right posterior ostium giving rise to a right coronary artery that passes to the right atrioventricular groove and a left coronary artery that passes posterior to the pulmonary artery. An understanding of the mechanisms by which this coronary pattern increases the risk of mortality has led to neutralization of this risk factor. The risk of late reintervention after an arterial switch with single coronary artery is increased with a single left posterior ostium with the right coronary passing anterior to the aorta. The mechanism remains unclear.


Asunto(s)
Vasos Coronarios/cirugía , Transposición de los Grandes Vasos/cirugía , Vasos Coronarios/embriología , Vasos Coronarios/patología , Humanos , Cuidados Posoperatorios , Cuidados Preoperatorios , Transposición de los Grandes Vasos/patología , Resultado del Tratamiento
17.
J Thorac Cardiovasc Surg ; 122(1): 154-61, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11436049

RESUMEN

OBJECTIVE: Early primary repair of tetralogy of Fallot has been routinely performed at Children's Hospital, Boston, since 1972. We evaluated the long-term outcome of this treatment strategy including the influence of a transannular patch. METHODS: Fifty-seven patients less than 24 months of age (median 8 months) underwent primary repair of tetralogy of Fallot between January 1972 and December 1977. Thirty-one patients had a transannular patch. Survival and freedom from reintervention were determined by the Kaplan-Meier method with 95% confidence intervals. RESULTS: There were 8 early deaths, and 1 patient died 24 years after initial repair. Recent follow-up was obtained for 45 of the 49 long-term survivors (92%). Median follow-up was 23.5 years. Ten patients underwent reintervention, 8 of whom underwent relief of right ventricular outflow tract obstruction. Right ventricular outflow tract obstruction occurred in 6 patients without a transannular patch and 2 with a transannular patch (33% vs 6%, P =.04). One pulmonary valve replacement was performed at another institution 20 years after the repair. Forty-one long-term survivors were in New York Heart Association class I and 4 were in class II. Actuarial survival was 86% at 20 years (95% confidence intervals = 80%-92%). Freedom from reintervention was 93% at 5 years (95% confidence intervals = 87%-99%) and 79% at 20 years (95% confidence intervals = 70%-86%). No significant differences were found between patients with and without a transannular patch (survival, P =.34; freedom from reintervention, P =.09, log-rank tests). CONCLUSIONS: Long-term survival is excellent and the freedom from reintervention is satisfactory after early primary repair of tetralogy of Fallot in the 1970s. Use of a transannular patch does not reduce late survival and is associated with a lower incidence of right ventricular outflow tract obstruction.


Asunto(s)
Tetralogía de Fallot/cirugía , Tolerancia al Ejercicio , Femenino , Humanos , Lactante , Masculino , Modelos de Riesgos Proporcionales , Prótesis e Implantes , Reoperación , Estudios Retrospectivos , Tetralogía de Fallot/mortalidad , Tetralogía de Fallot/fisiopatología , Resultado del Tratamiento
18.
Br J Radiol ; 74(879): 280-2, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11338109

RESUMEN

Ventricular septal defect (VSD) is the most frequent congenital heart disease (25-30%). The diagnosis of VSD is usually made echocardiographically by means of colour Doppler ultrasound, and is confirmed by angiocardiography in most cases. We describe a case in which an additional large trabecular VSD was demonstrated by MRI after previous cardiac catheterizations and angiocardiography in various hospitals. MRI allows an exact presentation of the anatomy, including areas that are difficult to assess, for instance the apical septum. Determination of cardiac output, regurgitation volume and the Qp/Qs quotient in patients with shunt volume in heart defects is also possible with one examination.


Asunto(s)
Defectos del Tabique Interventricular/diagnóstico , Adulto , Angiocardiografía , Cateterismo Cardíaco , Reacciones Falso Negativas , Femenino , Humanos , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...