Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ital J Pediatr ; 48(1): 173, 2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36109824

RESUMEN

BACKGROUND: Healthy sleep is essential for the cognitive, behavioral and emotional development of children. Therefore, this study aimed to assess the behavioral consequences of sleep disturbances by examining children with sleep-disordered breathing compared with control participants. METHODS: Seventy-eight children with SDB (average age: 6.7 years (SD = 1.83); 61 had OSA and 17 had primary snoring) and 156 control subjects (average age: 6.57 years (SD = 1.46) participated in the study. We matched the groups in age (t(232) = 0.578, p = 0.564) and gender (χ2(1) = 2.192, p = 0.139). In the SDB group, the average Apnea-Hypopnea Index was 3.44 event/h (SD = 4.00), the average desaturation level was 87.37% (SD = 6.91). Parent-report rating scales were used to measure the children's daytime behavior including Attention Deficit Hyperactivity Disorder Rating Scale, Strengths and Difficulties Questionnaire, and Child Behavior Checklist. RESULTS: Our results showed that children with SDB exhibited a higher level of inattentiveness and hyperactive behavior. Furthermore, the SDB group demonstrated more internalizing (anxiety, depression, somatic complaints, social problems) (p < 0.001) and externalizing (aggressive and rule-breaking behavior) problems compared with children without SDB, irrespective of severity. CONCLUSIONS: Based on our findings we supposed that snoring and mild OSA had a risk for developing behavioral and emotional dysfunctions as much as moderate-severe OSA. Therefore, clinical research and practice need to focus more on the accurate assessment and treatment of sleep disturbances in childhood, particularly primary snoring, and mild obstructive sleep apnea.


Asunto(s)
Problema de Conducta , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Niño , Humanos , Polisomnografía , Síndromes de la Apnea del Sueño/diagnóstico , Ronquido
2.
Ideggyogy Sz ; 73(1-2): 53-59, 2020 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-32057205

RESUMEN

Background - Several cochlear implant recipients experience functionality loss due to electrode array mal-positioning. The application of delicate perimodiolar electrodes has many electrophysiological advantages, however, these profiles may be more susceptible to tip fold-over. Purpose - The prompt realization of such complication following electrode insertion would be auspicious, thus the electrode could be possibly repositioned during the same surgical procedure. Methods - The authors present three tip fold-over cases, experienced throughout their work with Slim Modiolar Electrode implants. Implantations were performed through the round window approach, by a skilled surgeon. Standard intraoperative measurements (electric integrity, neural response telemetry, and electrical stapedial reflex threshold tests) were successfully completed. The electrode position was controlled by conventional radiography on the first postoperative day. Results - Tip fold-over was not tactilely sensated by the surgeon. Our subjects revealed normal intraoperative telemetry measurements, only the postoperative imaging showed the tip fold-over. Due to the emerging adverse perception of constant beeping noise, the device was replaced by a CI512 implant after 6 months in one case. In the two remaining cases, the electrode array was reloaded into a back-up sheath, and reinserted into the scala tympani successfully through an extended round window approach. Discussion - Future additional studies using the spread of excitation or electric field imaging may improve test reliability. As all of these measurements are still carried out following electrode insertion, real-time identification, unfortunately, remains questionable. Conclusion - Tip fold-over could be reliably identified by conventional X-ray imaging. By contrast, intraoperative electrophysiology was not sufficiently sensitive to reveal it.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Electrodos Implantados , Cóclea , Humanos , Reproducibilidad de los Resultados , Rampa Timpánica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...