1.
Rev Sci Instrum ; 90(3): 033502, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30927788

RESUMEN

Ion flow velocity measurement in the edge and scraper-off layer region is beneficial to understand the confinement related phenomenon in fusion devices such as impurity transport and plays an important role in impurity control. During the Wendelstein 7-X (W7-X) operation phase 1.2a, a multi-channel (MC) Mach probe mounted on the multi-purpose manipulator has been used to measure radial profiles of edge ion flow velocity. This MC-Mach probe consists of two polar and two radial arrays of directional Langmuir pins (28 pins in total) serving for different aims, of which the polar arrays could obtain a polar distribution of ion saturation current, while the radial arrays can be used to study the dynamic process of a radially propagated event. In this paper, we report the observation of the radially outward propagation of a low frequency mode with a speed of around 200 m/s. The first measurement of the radial ion flow velocity profile using the MC-Mach probe in the boundary plasma of the W7-X with an island divertor will also be presented.

2.
Rev Sci Instrum ; 89(10): 10F111, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399723

RESUMEN

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

3.
Rev Sci Instrum ; 89(10): 10G101, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399890

RESUMEN

This paper reports on the design and the performance of the recently upgraded X-ray imaging spectrometer systems, X-ray imaging crystal spectrometer and high resolution X-ray imaging spectrometer, installed at the optimized stellarator Wendelstein 7-X. High resolution spectra of highly ionized, He-like Si, Ar, Ti, and Fe as well as H-like Ar have been observed. A cross comparison of ion and electron temperature profiles derived from a spectral fit and tomographic inversion of Ar and Fe spectra shows a reasonable match with both the spectrometers. The also measured impurity density profiles of Ar and Fe have peaked densities at radial positions that are in qualitative agreement with the expectations from the He-like impurity fractional abundances, given the measured temperature profiles. Repeated measurements of impurity decay times have been demonstrated with an accuracy of 1 ms via injection of non-recycling Ti, Fe, and Mo impurities using a laser blow-off system.

4.
Rev Sci Instrum ; 89(7): 073505, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30068134

RESUMEN

We present a detailed overview and first results of the new laser blow-off system on the stellarator Wendelstein 7-X. The system allows impurity transport studies by the repetitive and controlled injection of different tracer ions into the plasma edge. A Nd:YAG laser is used to ablate a thin metal film, coated on a glass plate, with a repetition rate of up to 20 Hz. A remote-controlled adjustable optical system allows the variation of the laser spot diameter and enables the spot positioning to non-ablated areas on the target between laser pulses. During first experiments, clear spectral lines from higher ionization stages of the tracer ions have been observed in the X-ray to the extreme ultraviolet spectral range. The temporal behavior of the measured emission allows the estimate of transport properties, e.g., impurity transport times in the order of 100 ms. Although the strong injection of impurities is well detectable, the global plasma parameters are barely changed.

5.
Rev Sci Instrum ; 88(3): 033509, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28372367

RESUMEN

In magnetically confined fusion plasmas controlled gas injection is crucial for plasma fuelling as well as for various diagnostic applications such as active spectroscopy. We present a new, versatile system for the injection of collimated thermal gas beams into a vacuum chamber. This system consists of a gas pressure chamber, sealed by a custom made piezo valve towards a small capillary for gas injection. The setup can directly be placed inside of the vacuum chamber of fusion devices as it is small and immune against high magnetic fields. This enables gas injection close to the plasma periphery with high duty cycles and fast switch on/off times ≲ 0.5 ms. In this work, we present the design details of this new injection system and a systematic characterization of the beam properties as well as the gas flowrates which can be accomplished. The thin and relatively short capillary yields a small divergence of the injected beam with a half opening angle of 20°. The gas box is designed for pre-fill pressures of 10 mbar up to 100 bars and makes a flowrate accessible from 1018 part/s up to 1023 part/s. It hence is a versatile system for both diagnostic as well as fuelling applications. The implementation of this system in ASDEX Upgrade will be described and its application for line ratio spectroscopy on helium will be demonstrated on a selected example.

6.
Rev Sci Instrum ; 87(11): 11E554, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910613

RESUMEN

A beam emission spectroscopy system on thermal helium (He) and neon (Ne) has been set up at Wendelstein 7-X to measure edge electron temperature and density profiles utilizing the line-ratio technique or its extension by the analysis of absolutely calibrated line emissions. The setup for a first systematic test of these techniques of quantitative atomic spectroscopy in the limiter startup phase (OP1.1) is reported together with first measured profiles. This setup and the first results are an important test for developing the technique for the upcoming high density, low temperature island divertor regime.

7.
Rev Sci Instrum ; 85(11): 11D818, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430231

RESUMEN

An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

8.
Rev Sci Instrum ; 84(5): 053501, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23742545

RESUMEN

Gas puff imaging (GPI) [S. J. Zweben, D. P. Stotler et al., Phys. Plasmas 9, 1981 (2002); R. J. Maqueda, G. A. Wurden et al., Rev. Sci. Instrum. 74, 2020 (2003)] is a powerful diagnostic that permits a two-dimensional measurement of turbulence in the edge region of a fusion plasma and is based on the observation of the local emission of a neutral gas, actively puffed into the periphery of the plasma. The developed in-vessel GPI telescope observes the emission from the puffed gas along local (at the puff) magnetic field lines. The GPI telescope is specially designed to operate in severe TEXTOR conditions and can be treated as a prototype for the GPI systems on next generation machines. Also, the gas puff nozzle is designed to have a lower divergence of the gas flow than previous GPI diagnostics. The resulting images show poloidally and radially propagating structures, which are associated with plasma blobs. We demonstrate that the local gas puff does not disturb plasma properties. Our results indicate also that the neutral gas emission intensity is more sensitive to the electron density than the electron temperature. Here, we present implementation details of the GPI system on TEXTOR and discuss some design and diagnostic issues related to the development of GPI systems in general.

9.
Rev Sci Instrum ; 83(10): 10D318, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126844

RESUMEN

MeV particle loss measurements from fusion plasmas, in particular alpha particles, remain difficult in large fusion devices and further R&D is needed for ITER. This paper describes the first attempt to measure 3 MeV escaping fusion protons emitted from TEXTOR tokamak plasmas using activation technique. This technique was successfully demonstrated, initially, in 2006 on the JET tokamak. An ion camera equipped with a collimator and several types of activation detectors was installed inside the TEXTOR vacuum vessel to perform these measurements. After irradiation, the detectors were analyzed using ultra low level gamma-ray spectrometry at the HADES underground laboratory. 3 MeV escaping fusion protons were detected in larger number -~6 times more--compared to earlier measurements using this technique on JET. Another major progress was the reduction of the cooling time by a factor of 50, which made possible to detect radionuclides with half-life of less than 90 min.

10.
Rev Sci Instrum ; 83(10): 10D511, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23130790

RESUMEN

A new endoscope with optimised divertor view has been developed in order to survey and monitor the emission of specific impurities such as tungsten and the remaining carbon as well as beryllium in the tungsten divertor of JET after the implementation of the ITER-like wall in 2011. The endoscope is a prototype for testing an ITER relevant design concept based on reflective optics only. It may be subject to high neutron fluxes as expected in ITER. The operating wavelength range, from 390 nm to 2500 nm, allows the measurements of the emission of all expected impurities (W I, Be II, C I, C II, C III) with high optical transmittance (≥ 30% in the designed wavelength range) as well as high spatial resolution that is ≤ 2 mm at the object plane and ≤ 3 mm for the full depth of field (± 0.7 m). The new optical design includes options for in situ calibration of the endoscope transmittance during the experimental campaign, which allows the continuous tracing of possible transmittance degradation with time due to impurity deposition and erosion by fast neutral particles. In parallel to the new optical design, a new type of possibly ITER relevant shutter system based on pneumatic techniques has been developed and integrated into the endoscope head. The endoscope is equipped with four digital CCD cameras, each combined with two filter wheels for narrow band interference and neutral density filters. Additionally, two protection cameras in the λ > 0.95 µm range have been integrated in the optical design for the real time wall protection during the plasma operation of JET.

11.
Rev Sci Instrum ; 83(10): 10D727, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23130796

RESUMEN

The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.

12.
Rev Sci Instrum ; 83(6): 065107, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22755662

RESUMEN

A supersonic helium beam diagnostic, based on the line-ratio technique for high resolution electron density and temperature measurements in the plasma edge (r/a > 0.9) was designed, built, and optimised at TEXTOR (Torus Experiment for Technology Oriented Research). The supersonic injection system, based on the Campargue skimmer-nozzle concept, was developed and optimised in order to provide both a high neutral helium beam density of n(0) = 1.5 × 10(18) m(-3) and a low beam divergence of ±1° simultaneously, achieving a poloidal resolution of Δ(poloidal) = 9 mm. The setup utilises a newly developed dead volume free piezo valve for operation in a high magnetic field environment of up to 2 T with a maximum repetition rate of 80 Hz. Gas injections are realised for a duration of 120 ms at a repetition rate of 2 Hz (duty cycle 1/3). In combination with a high sensitivity detection system, consisting of three 32 multi-channel photomultipliers (PMTs), measurements of edge electron temperature and density with a radial resolution of Δ(radial) = 2 mm and a maximum temporal resolution of Δt ≃ 2 µs (470 kHz) are possible for the first time. The diagnostic setup at TEXTOR is presented. The newly developed injection system and its theoretical bases are discussed. The applicability of the stationary collisional-radiative model as basis of the line-ratio technique is shown. Finally, an example of a fluctuation analysis demonstrating the unique high temporal and spatial resolution capabilities of this new diagnostic is presented.

13.
Rev Sci Instrum ; 83(2): 02B707, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380312

RESUMEN

The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35°. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.

14.
Rev Sci Instrum ; 81(10): 10E133, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033995

RESUMEN

The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

15.
Rev Sci Instrum ; 81(2): 02B104, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20192411

RESUMEN

The status and the executing modernization of RUssian Diagnostic Injector (RUDI) are described. The ion source consists of arc plasma emitter and multiaperture four-electrode ion optical system. The present ion optical system with round beamlets is to be replaced by new slit apertures system for the reducing beam angular divergence in one direction. Due to enlarged dimensions and transparency of new ion optical system the extracted ion beam current will be by 50% increased. For the extension of beam pulse duration from 4 s to 8-10 s an optimized metal-ceramic arc-discharge channel is introduced. In the paper, the optical measurements results of beam parameters, including the profile of species distribution, scanned by custom-built multichannel spectroscope, are also presented.

16.
Rev Sci Instrum ; 79(10): 10E708, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044526

RESUMEN

The design and main characteristics of 14-channel dispersion interferometer for plasma profile measurement and control in TEXTOR tokamak are presented. The diagnostic is engineered on the basis of modular concept, the 10.6 microm CO(2) laser source and all optical and mechanical elements of each module are arranged in a compact housing. A set of mirrors and retroreflectors inside the TEXTOR vacuum vessel provides full coverage of the torus cross section with 12 vertical and two diagonal lines of sight, no rigid frame for vibration isolation is required. Results of testing of the single-channel prototype diagnostic and the pilot module of the multichannel dispersion interferometer are presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...