1.
Minerva Ginecol ; 43(6): 269-72, 1991 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-1922898

RESUMEN

One hundred physiological pregnant women and 76 pathological pregnant women suffering from gestational diabetes and pregnancy-induced hypertension underwent a cardiotocographic examination during the course of routine diagnostic tests. The interpretation of cardiotocographic printouts was carried out using traditional as well as computerised methods. The outcome of these tests was then related to neonatal outcome and other parameters which contributed to defining the prognosis of pregnancy. Computerised analysis was found to provide a more reliable diagnosis in comparison to traditional methods in identifying those pregnancies with a pathological neonatal outcome. In particular, in the group of physiological pregnancies, computerised interpretation proved more reliable in 87.5% of cases in which neonatal outcome was pathological; on the contrary, traditional interpretations only revealed 37.5% of the same cases. In pathological pregnancies, automatic interpretation was also found to be more reliable in predicting the non-pathological outcomes, whereas traditional methods provided a high incidence of uncertain answers.


Asunto(s)
Cardiotocografía , Monitoreo Fetal , Complicaciones Cardiovasculares del Embarazo/fisiopatología , Embarazo en Diabéticas/fisiopatología , Diagnóstico por Computador , Femenino , Enfermedades Fetales/diagnóstico , Viabilidad Fetal , Humanos , Embarazo
2.
Respiration ; 52(2): 137-43, 1987.
Artículo en Inglés | MEDLINE | ID: mdl-3671892

RESUMEN

Histamine inhalation provocation tests were performed in 18 asymptomatic asthmatic patients with progressively increasing doses of a pressurized aerosol of histamine phosphate. Forced expiratory volume in 1 s (FEV1), total neuromuscular output, assessed by mouth occlusion pressure (P0.1), mean inspiratory flow (VT/Ti), and the P0.1/(VT/Ti) ratio, which represents an index of effective inspiratory impedance of the respiratory system, were measured. With histamine, compared to control, FEV1 decreased and P0.1/(VT/Ti) increased (p less than 0.01 for both). After bronchoconstriction was reversed by administration of a beta 2-agonist bronchodilator (fenoterol), a significant decrease in P0.1/(VT/Ti) (p less than 0.001) and a significant increase in FEV1 (p less than 0.01) were noted as compared to histamine. With histamine, change in P0.1/(VT/Ti) was found to be related to its pre-histamine value (p less than 0.01). Furthermore, with histamine and fenoterol, changes in P0.1/(VT/Ti) and concurrent changes in FEV1 were found to be significantly related (p less than 0.001). From these data we calculated that the P0.1/(VT/Ti) ratio provides a useful tool in the clinical assessment of histamine-induced bronchospasm.


Asunto(s)
Asma/diagnóstico , Pruebas de Provocación Bronquial/métodos , Espasmo Bronquial/diagnóstico , Histamina/análogos & derivados , Adulto , Resistencia de las Vías Respiratorias/efectos de los fármacos , Asma/tratamiento farmacológico , Espasmo Bronquial/tratamiento farmacológico , Femenino , Fenoterol/uso terapéutico , Humanos , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad