Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ther Apher ; 2(1): 65-70, 1998 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10227791

RESUMEN

It has been reported that serum lipoprotein(a) (Lp[a]) levels in patients with restenosis after percutaneous transluminal coronary angioplasty (PTCA) were significantly higher than in patients without restenosis. In this study, we evaluated the preventive effect of LDL apheresis on restenosis after PTCA in patients with hypercholesterolemia. For 10 patients who had shown a serum cholesterol level of more than 220 mg/dl despite treatment with antihypercholesterolemic drugs, LDL apheresis was conducted every 2 weeks after a successful PTCA until restenosis could be checked. In 4 patients, LDL apheresis was conducted for 2 years. LDL apheresis significantly reduced serum cholesterol from 248 +/- 22 mg/dl to 135 +/- 26 mg/dl and Lp(a) from 42 +/- 34 mg/dl to 21 +/- 16 mg/dl. The average degree of stenosis in the 11 lesions undergoing PTCA was 92 +/- 6% before PTCA, 35 +/- 10% immediately after PTCA, and 38 +/- 19% at 3 to 4 months after PTCA. Restenosis was observed in only 1 lesion. In 4 patients who received LDL apheresis for 2 years, restenosis did not occur in any of the 4 lesions treated. We concluded that LDL apheresis was an efficacious therapy to prevent restenosis after PTCA in patients with hypercholesterolemia.


Asunto(s)
Angioplastia Coronaria con Balón , Eliminación de Componentes Sanguíneos/métodos , Enfermedad Coronaria/etiología , Enfermedad Coronaria/terapia , Hipercolesterolemia/complicaciones , Lipoproteínas LDL/sangre , Adulto , Anticolesterolemiantes/uso terapéutico , Colesterol/sangre , Terapia Combinada , Enfermedad Coronaria/sangre , Femenino , Estudios de Seguimiento , Humanos , Hipercolesterolemia/sangre , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
2.
J Nucl Med ; 38(7): 1073-8, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9225793

RESUMEN

UNLABELLED: The aim of this study was to determine whether late redistribution imaging after rest injection of 201Tl would provide further information on myocardial viability over conventional rest-early redistribution 201Tl imaging. METHODS: Twenty-nine patients with coronary artery disease and left ventricular dysfunction underwent rest, early (3-4 hr) and late (20-24 hr) redistribution 201Tl and gated blood pool studies. In 14 patients with successful revascularization, gated blood pool study was repeated after the coronary intervention. RESULTS: Nine of 29 patients showed early redistribution, and six additional patients showed further redistribution on the late images. Of 136 segments with initial 201Tl defects, 18 showed early redistribution, and 10 showed late redistribution. When a threshold of 60% of peak activity was used as an index of myocardial viability, only a small fraction (3%) of the initial 201Tl defects were additionally considered viable by the late images. In 14 patients who underwent revascularization, the positive (69%) and negative (87%) predictive values of the early redistribution images for functional recovery were similar to those obtained by the late images (68% and 86%, respectively). CONCLUSION: Although late redistribution after rest injection of 201Tl occasionally occurs, most of the clinically relevant information on myocardial viability may be obtained by conventional rest-early redistribution 201Tl imaging when the defect severity is considered an index of tissue viability.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Radioisótopos de Talio , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Enfermedad Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía por Radionúclidos , Descanso , Supervivencia Tisular , Disfunción Ventricular Izquierda/terapia
3.
J Am Coll Cardiol ; 29(6): 1226-33, 1997 May.
Artículo en Inglés | MEDLINE | ID: mdl-9137217

RESUMEN

OBJECTIVES: This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND: Tc-99m tetrofosmin is a new myocardial perfusion imaging agent, but its role for detecting viable myocardium is still unclear. METHODS: Thirty-six patients with coronary artery disease and left ventricular dysfunction underwent rest Tc-99m tetrofosmin, rest-redistribution Tl-201 and gated blood pool scintigraphy. In 21 patients with successful revascularization confirmed by follow-up angiography, gated blood pool scintigraphy was repeated after revascularization. Optimal threshold cutoffs to separate reversible from irreversible dysfunction were determined by receive operating characteristic analysis. RESULTS: Regional Tc-99m tetrofosimin activity highly correlated with redistribution Tl-201 activity (r = 0.93). The diagnostic performance for predicting functional recovery, as measured by the area under the receiver operating characteristic curves, measured 0.66 +/- 0.07 (mean +/- SD) for Tc-99m tetrofosmin and 0.67 +/- 0.07 for Tl-201 (p = 0.60, 96.7% power to detect difference in area of 0.10). The optimal threshold cutoffs for viability were considered to be 50% of peak activity for Tc-99m tetrofosmin and 55% of peak activity for Tl-201. The positive and negative predictive values for reversible dysfunction were, respectively, 69% and 82% for Tc-99m tetrofosmin and 69% (p = 0.99 vs. Tc-99m tetrofosmin) and 71% (p = 0.66 vs. Tc-99m tetrofosmin) by Tl-201. CONCLUSIONS: The diagnostic performance of quantitative rest Tc-99m tetrofosmin imaging in predicting functional recovery after revascularization is comparable to that of rest-redistribution Tl-201.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Corazón/diagnóstico por imagen , Compuestos Organofosforados , Compuestos de Organotecnecio , Radioisótopos de Talio , Anciano , Angioplastia Coronaria con Balón , Estudios de Casos y Controles , Puente de Arteria Coronaria , Femenino , Imagen de Acumulación Sanguínea de Compuerta , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Radiofármacos , Tomografía Computarizada de Emisión de Fotón Único , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia
4.
Am Heart J ; 131(3): 458-65, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8604624

RESUMEN

Iodine 123-labeled 15-iodophenyl-3-methyl-pentadecanoic acid (BMIPP) has been proposed as a potential myocardial fatty acid probe. We studied BMIPP uptake in ischemic myocardium identified by thallium reinjection. Fifty-five patients with coronary artery disease who had persistent defects on standard exercise-redistribution thallium imaging were investigated. Patients underwent exercise-redistribution-reinjection thallium and resting BMIPP imaging. BMIPP uptake less than that seen with thallium on reinjection imaging was observed in 105 (82%) of 128 myocardial segments with new fill-in after thallium reinjection and 87 (37%) of 238 segments with reversible thallium defects. In contrast, only 32 (19%) of 166 segments with no fill-in showed discordantly decreased BMIPP uptake. Quantitative analysis showed reduction in BMIPP activity compared with differential uptake of thallium, an index of resting myocardial perfusion, especially in the area of fill-in (53.5% +/- 15.0% vs 76% +/- 12.1% of peak; p<0.01). These observations are consistent with impaired fatty acid uptake in ischemic myocardium, particularly in the area of fill-in after thallium reinjection.


Asunto(s)
Ácidos Grasos/metabolismo , Corazón/diagnóstico por imagen , Isquemia Miocárdica/metabolismo , Radioisótopos de Talio , Adulto , Anciano , Anciano de 80 o más Años , Prueba de Esfuerzo , Femenino , Humanos , Radioisótopos de Yodo , Yodobencenos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Miocardio/metabolismo , Supervivencia Tisular , Tomografía Computarizada de Emisión de Fotón Único
5.
Am J Cardiol ; 77(5): 350-4, 1996 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-8602561

RESUMEN

Defect size on exercise-rest technetium (Tc)-99m tetrofosmin myocardial perfusion imaging was compared with that on exercise-reinjection thallium-201 imaging with 20 patients with 1-vessel coronary artery disease. In each patient, exercise-reinjection thallium-201 single-photon emission computed tomography (SPECT) and exercise-rest Tc-99m tetrofosmin SPECT imaging were performed. For visual analysis of the obtained SPECT images, the left ventricular myocardium was divided into 20 segments based on 3 short-axis slices from the apical, middle, and basal ventricular levels. For quantitative analysis, a square region of interest was placed on the center of each segment which was used for visual analysis, and relative regional activity to the normal reference region was calculated for each segment. By visual interpretation of the images, exercise Tc-99m tetrofosmin imaging showed a smaller defect size than exercise thallium-201 imaging (6.9 +/- 3.9 vs 8.8 +/- 3.0 segments, p <0.01). In contrast, rest Tc-99m tetrofosmin imaging showed a defect size similar to that on reinjection thallium-201 imaging (5.9 +/- 3.6 vs 5.6 +/- 3.9 segments, p = NS). Similarly, the mean defect sizes during exercise determined by quantitative analysis were smaller on Tc-99m tetrofosmin SPECT than those on thallium-201 SPECT at all tested threshold cutoff points ranging from 50% to 70%, whereas there were no significant differences in defect sizes between rest Tc-99m tetrofosmin and reinjection thallium-201 imaging. These data indicate that exercise Tc-99m tetrofosmin SPECT defect size determined either by visual analysis or by quantitative analysis may be smaller than on exercise thallium-201 SPECT.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Compuestos Organofosforados , Compuestos de Organotecnecio , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Constricción Patológica , Enfermedad Coronaria/patología , Vasos Coronarios/patología , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Talio
6.
J Nucl Med ; 36(11): 1961-7, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7472582

RESUMEN

UNLABELLED: Exercise-rest 99mTc-tetrofosmin myocardial perfusion images with a 2-day protocol was compared to exercise-redistribution-reinjection 201Tl images to assess the ability of 99mTc-tetrofosmin to detect viable myocardium. METHODS: We studied 25 patients with coronary artery disease and regional or global left ventricular dysfunction. Myocardial SPECT images with 99mTc-tetrofosmin were obtained 10 min after injection during exercise and 1 and 3 hr after rest injection. Within 1 wk of the 99mTc-tetrofosmin study, exercise-redistribution-reinjection 201Tl SPECT imaging was performed. RESULTS: Visual analysis demonstrated concordance between 201Tl and 99mTc-tetrofosmin imaging for defect reversibility in 126 of 209 segments (60%), with initial defects on both exercise 201Tl and 99mTc-tetrofosmin images. In the remaining discordant 83 segments (40%), 73 (88%) appeared nonreversible on 99mTc-tetrofosmin imaging but were reversible on 201Tl imaging. CONCLUSION: On the basis of defect reversibility by visual analysis, exercise-rest 99mTc-tetrofosmin imaging underestimates myocardial viability compared to 201Tl reinjection imaging. The identification of viable myocardium with both 99mTc-tetrofosmin and 201Tl can be greatly enhanced to a similar degree if the severity of reduction in activity within nonreversible defects is considered. These two agents may provide comparable information about myocardial viability by quantitative analysis of defect severity.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Compuestos Organofosforados , Compuestos de Organotecnecio , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único , Prueba de Esfuerzo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA