Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Perfusion ; 27(3): 176-82, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22337763

RESUMEN

Although a growing body of evidence indicates superiority of minimized cardiopulmonary bypass (mCPB) systems over conventional CPB systems, limited venous return can result in severe fluctuations of venous line pressure which can result in gaseous emboli. In this study, we investigated the influence of sub-atmospheric pressures and volume buffer capacity added to the venous line on the generation of gaseous emboli in the mCPB circuit. Two different mCPB systems (MEC - Maquet, n=7 and ECC.O - Sorin, n=8) and a conventional closed cardiopulmonary bypass (cCPB) system (n=12) were clinically evaluated. In the search for a way to increase volume buffer capacity of mCPB systems, we additionally evaluated the 'Better Bladder' (BB) in a mock circulation by simulating, repeatedly, decreased venous return while measuring pressure and gaseous embolic activity. Arterial gaseous emboli activity during clinical perfusion with a cCPB system was the lowest in comparison to the mCPB systems (312±465 versus 311±421 with MEC and 1,966±1,782 with ECC.O, counts per 10 minute time interval, respectively; p=0.03). The average volume per bubble in the arterial line was the highest in cases with cCPB (12.5±8.3 nL versus 8.0±4.2 nL with MEC and 4.6±4.8 nL with ECC.O; p=0.04 for both). Significant cross-correlation was obtained at various time offsets from 0 to +35 s between sub-atmospheric pressure in the venous line and gaseous emboli activity in both the venous and arterial lines. The in vitro data showed that incorporation of the BB dampens fluctuations of venous line pressure by approximately 30% and decreases gaseous emboli by up to 85%. In conclusion, fluctuations of sub-atmospheric venous line pressure during kinetic-assisted drainage are related to gaseous emboli. Volume buffer capacity added to the venous line can effectively dampen pressure fluctuations resulting from abrupt changes in venous return and, therefore, can help to increase the safety of minimized cardiopulmonary bypass by reducing gaseous microemboli formation resulting from degassing.


Asunto(s)
Puente Cardiopulmonar/instrumentación , Presión Atmosférica , Humanos , Cinética , Perfusión
2.
Perfusion ; 26(4): 315-21, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21593085

RESUMEN

The hypothesis was tested whether retrograde autologous priming (RAP) of the cardiopulmonary bypass system, compared to a standard primed system (NON-RAP group), results in less haemodilution and less transfusion of packed red blood cells. Retrospectively, data was collected from the medical charts of one hundred patients undergoing elective coronary artery bypass grafting using cardiopulmonary bypass. Fifty patients where RAP was used have been compared to fifty patients using NON-RAP. The prime volume in the NON-RAP group was 1,627±108 mL versus 782±96 mL in the RAP group (p<0.001). The lowest haematocrit during perfusion was 22% in the NON-RAP group versus 26% when the RAP technique was used (p<0.001). In the NON-RAP group, 26% of the patients received packed red cells in contrast to 6% in the RAP group (p<0.012). A positive association was found between RAP and less transfusion of packed red blood cells (p<0.012). In conclusion, retrograde autologous priming, reducing the prime volume of the cardiopulmonary bypass system, causes less haemodilution and reduces intraoperative transfusion of packed red blood cells.


Asunto(s)
Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Transfusión de Eritrocitos , Hemodilución , Cuidados Intraoperatorios/instrumentación , Cuidados Intraoperatorios/métodos , Anciano , Puente Cardiopulmonar/normas , Femenino , Hematócrito , Humanos , Cuidados Intraoperatorios/normas , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...