Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
BMJ Open Ophthalmol ; 8(Suppl 3): A1, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37797997

RESUMEN

INTRODUCTION: Prompt detection of childhood uveitis is key to minimising negative impact. From an internationally unique inception cohort, we report pathways to disease detection.UNICORNS is a national childhood non-infectious uveitis study with longitudinal collection of a standardised clinical dataset and patient reported outcomes. Descriptive analysis of baseline characteristics are reported.Amongst 150 recruited children (51% female, 31% non-white ethnicity) age at detection ranged from 2-18yrs (median 10). In 69%, uveitis was diagnosed following onset of symptoms: time from first symptoms to uveitis detection ranged from 0-739days (median 7days), with longer time to detection for those presenting initially to their general practitioner. Non symptomatic children were detected through JIA/other disease surveillance (16%), routine optometry review (5%) or child visual health screening (1%). Commonest underlying diagnoses at uveitis detection were JIA (17%), TINU (9%, higher than pre-pandemic reported UK disease frequency) and sarcoid (1%). 60% had no known systemic disease at uveitis detection. At disease detection, in at least one eye: 34% had structural complications (associated with greater time to detection - 17 days versus 4 days for uncomplicated presentation).The larger relative proportions of children with non-JIA uveitis reported here increase the importance of improving awareness of childhood uveitis amongst the wider clinical communities. There is scope for improvement of pathways to detection. Forthcoming analysis on the full cohort (251 recruited to date across 33 hospitals and 4 nations) will provide nationally representative data on management and the determinants of visual and broader developmental/well-being outcomes.


Asunto(s)
Artritis Juvenil , Uveítis , Niño , Humanos , Femenino , Preescolar , Adolescente , Masculino , Estudios de Cohortes , Artritis Juvenil/complicaciones , Uveítis/diagnóstico , Reino Unido/epidemiología
4.
Cureus ; 13(10): e18956, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34815902

RESUMEN

We present the case of a 69-year-old man patient who was brought with a history of gait disturbances, memory impairment, and urinary incontinence with gradual worsening over the past six months. The patient underwent magnetic resonance imaging of the brain which demonstrated enlarged ventricles, widening of the Sylvian fissure, and narrow sulci at the vertex. Subsequently, the patient underwent a lumbar puncture which revealed a normal opening pressure with normal cerebrospinal fluid analysis. The diagnosis of normal pressure hydrocephalus was established. The patient underwent a ventriculoperitoneal shunt for the management of his symptoms. Three years after the placement of the shunt, the patient was brought to the emergency department with an expanding right-sided subcutaneous abdominal mass. A computed tomography scan of the abdomen showed the subcutaneous mass superficial to the right rectus muscle and was containing the coiled distal end of the shunt. Such findings were consistent with a subcutaneous cerebrospinal fluid pseudocyst. The mass was aspirated and the fluid analysis was in keeping with the cerebrospinal fluid characteristics. The fluid culture revealed no bacterial growth. The ventriculoperitoneal shunt was replaced with a minimally invasive technique.

5.
Polymers (Basel) ; 13(16)2021 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-34451248

RESUMEN

Natural fiber such as bamboo fiber, oil palm empty fruit bunch (OPEFB) fiber, kenaf fiber, and sugar palm fiber-reinforced polymer composites are being increasingly developed for lightweight structures with high specific strength in the automotive, marine, aerospace, and construction industries with significant economic benefits, sustainability, and environmental benefits. The plant-based natural fibers are hydrophilic, which is incompatible with hydrophobic polymer matrices. This leads to a reduction of their interfacial bonding and to the poor thermal stability performance of the resulting fiber-reinforced polymer composite. Based on the literature, the effect of chemical treatment of natural fiber-reinforced polymer composites had significantly influenced the thermogravimetric analysis (TGA) together with the thermal stability performance of the composite structure. In this review, the effect of chemical treatments used on cellulose natural fiber-reinforced thermoplastic and thermosetting polymer composites has been reviewed. From the present review, the TGA data are useful as guidance in determining the purity and composition of the composites' structures, drying, and the ignition temperatures of materials. Knowing the stability temperatures of compounds based on their weight, changes in the temperature dependence is another factor to consider regarding the effectiveness of chemical treatments for the purpose of synergizing the chemical bonding between the natural fiber with polymer matrix or with the synthetic fibers.

6.
Br J Oral Maxillofac Surg ; 59(3): 320-328, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33280945

RESUMEN

This second part explores perceptions and understanding of clinical performance, turnaround, and costs for printed titanium implants or plates in common procedures, evaluating both 'in-house' and 'outsourced' CAD-CAM pathways. A cross-sectional study, supported by the British Association of Oral and Maxillofacial Surgeons (BAOMS) and a national trainee-led recruitment team, was conducted over 14 weeks. A total of 132 participants took part (demographic data is reported in Part I). For fibular-flap mandibular reconstruction, most participants (69% - 91%) perceived printed titanium as superior to intraoperatively or preoperatively hand-bent plates for surgical duration, accuracy, dental restorability, and aesthetics. There was less agreement about complications and plate-failure risks. Most perceived printed plates to be superior to traditional wafer-based maxillary osteotomy for surgical duration (61%) and maxillary positioning (60%). For orbital floor repair, most perceived improvements in surgical duration (83%, especially higher-volume operators p=0.009), precision (84%), and ease of placement (69%). Rarely (less than 5%) was any outcome rated inferior to traditional techniques for any procedure. Perceived turnaround times and costs were variable, but the greatest consensus was for two-segment fibular-flap reconstructions and orbital floor repair. Industry estimates were generally consistent between two company representatives, but manufacturing-only costs differed when using in-house (departmental) designers. Costs and turnaround times are questionable barriers since few understand 'real-world' figures. Designing in-house can dramatically alter costs. Improved accuracy and surgical duration are common themes but biomechanical benefits are less-well understood. This study paints a picture of the potentially routine applications and benefits of printed titanium, capacity for uptake, understanding amongst surgeons, and areas for improvement.


Asunto(s)
Procedimientos de Cirugía Plástica , Cirugía Asistida por Computador , Estudios Transversales , Estética Dental , Humanos , Impresión Tridimensional , Titanio , Reino Unido
7.
Br J Oral Maxillofac Surg ; 59(3): 312-319, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33280946

RESUMEN

This first part of a two-part study examines perceived applications for and barriers to using printed titanium in light of current caseloads, funding pathways, and use of digital planning. It aims to demonstrate the scope for printed titanium in modern practice and to guide industry about the needs of UK surgeons. A cross-sectional study over 14 weeks was performed electronically with support from the British Association of Oral and Maxillofacial Surgeons (BAOMS) and a national trainee-led recruitment team. Ethics approval was obtained at the lead centre. A total of 132 participants joined the study (70% consultants, 25% specialty registrars, and 5% other), approximating a 29% response rate from consultant/registrar BAOMS members throughout mainland UK. Eighty-eight per cent used CAD-CAM design, with highly variable funding/access, design/manufacturing workflows (in-house/outsourced). Eighty-eight per cent were involved with trauma, 61% with orthognathic, and 52% with oncology-reconstruction surgery. Favourite applications for printed titanium were orbital floor repair (89%) and free-flap jaw reconstruction (87%). Most participants also cited maxillary/zygomatic osteotomies and cranioplasty (range 61%-73%). Although a popular application (78%), the evidence base in temporomandibular joint surgery is limited. Those performing orthognathic surgery perceived more indications than those who did not (p=0.013). Key barriers included cost, turnaround time and logistics, and the need to be trained in traditional techniques. Printed titanium was useful for both common and niche procedures, but was specifically limited in emergency trauma. Most surgeons had experience in CAD-CAM surgery but technical understanding appeared unclear. Limiting factors included variable funding and production pathways, perceived costs, and logistics, but in-house design can minimise them. In part II, we quantify perceived benefits and limitations and whether surgeons' understanding and knowledge are sufficient to rationalise them.


Asunto(s)
Implantes Dentales , Procedimientos de Cirugía Plástica , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Estudios Transversales , Humanos , Impresión Tridimensional , Titanio , Reino Unido
9.
Oral Maxillofac Surg ; 24(2): 217-219, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31814066

RESUMEN

PURPOSE: Three-dimensional (3D) printing plays an important role in the diagnosis and treatment planning of many elective procedures in oral and maxillofacial surgery (OMFS). 3D printers and the associated print materials are now within the price range of most maxillofacial units, requiring less work to be sent out to commercial printers. Whilst their use in the planning of elective procedures is commonplace, acute trauma is an area where 3D printing remains underutilised. The successful management of complex fracture patterns such as concomitant symphyseal/parasymphyseal and bilateral condylar fractures often warrants this approach. METHODS: Freeware digital processing and manipulation software packages were used to view and segment structures from computed tomography (CT) data. Thereafter, fractures were digitally reduced. 3D printed models were produced from the digitally reduced models, allowing preoperative custom adaptation of osteosynthesis plates, facilitating accurate fracture fixation intraoperatively. RESULTS: For less than one hundred pounds sterling (STG), a 3D printer (with print material) capable of producing a model of sufficient quality can be purchased. The use of freeware digital processing software allows digital manipulation of CT data. Production of 3D models and plate adaptation can be carried out within hours after CT examination. CONCLUSIONS: The construction of digitally reduced 3D models and custom adapted plates enables the surgeon to achieve accurate fixation of complex fracture patterns in theatre which is clearly of benefit to patients. The potential for reduced theatre time also renders this approach more desirable, making this a worthwhile investment despite the additional non-clinical time associated with training and initial expenditure.


Asunto(s)
Fracturas Óseas , Impresión Tridimensional , Placas Óseas , Fijación Interna de Fracturas , Humanos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA