Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Pol J Radiol ; 87: e592-e596, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36532249

RESUMEN

Purpose: Unenhanced magnetic resonance imaging (MRI) is known to be useful in characterizing adrenal adenomas through the implementation of in-phase (IPI) and opposed-phase imaging (OPI) based on chemical shift artifacts. However, whether unenhanced MRI can contribute to the identification of right adrenal vein (RAV) remains unclear. The aim of this study was to evaluate the feasibility of unenhanced MRI for the identification of RAV. Material and methods: This retrospective study reviewed 30 patients (16 men; median age 60 years; range 34-76 years) who underwent MRI and subsequent adrenal venous sampling (AVS). Chemical shift MRI was acquired using echo times of 2.3 ms (OPI) and 4.6 ms (IPI) with a slice thickness of 3 mm and a gap of 1 mm. T2-weighted imaging (T2WI) was also performed. Identification of RAVs was performed by 2 independent radiologists. Inter-observer agreement on a 3-point rating scale was evaluated using κ statistics. The identification rate of RAVs was compared between OPI, IPI, and T2WI using McNemar's test. Results: Good inter-observer agreement was found for the OPI (κ = 0.744), whereas fair agreement was obtained for both other sequences (IPI: κ = 0.375; T2WI: 0.348). For both raters, the identification rate of RAVs was higher with OPI (36/60; 60.0%) than with other sequences (IPI: 16/60, 26.7%; T2WI: 9/60, 15.0%; p < 0.05, each). Conclusions: OPI may play a screening role in the identification of RAVs preceding AVS, which could reduce the required radiation exposure and doses of contrast agent.

2.
Neuroradiology ; 64(2): 279-288, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34247261

RESUMEN

PURPOSE: To discover common biomarkers correlating with the Mini-Mental State Examination (MMSE) scores from multi-country MRI datasets. METHODS: The first dataset comprised 112 subjects (49 men, 63 women; range, 46-94 years) at the National Hospital Organization Kyushu Medical Center. A second dataset comprised 300 subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database (177 men, 123 women; range, 57-91 years). Three-dimensional T1-weighted MR images were collected from both datasets. In total, 14 deep gray matter volumes and 70 cortical thicknesses were obtained from MR images using FreeSurfer software. Total hippocampal volume and the ratio of hippocampus to cerebral volume were also calculated. Correlations between each variable and MMSE scores were assessed using Pearson's correlation coefficient. Parameters with moderate correlation coefficients (r > 0.3) from each dataset were determined as independent variables and evaluated using general linear model (GLM) analyses. RESULTS: In Pearson's correlation coefficient, total and bilateral hippocampal volumes, right amygdala volume, and right entorhinal cortex (ERC) thickness showed moderate correlation coefficients (r > 0.3) with MMSE scores from the first dataset. The ADNI dataset showed moderate correlations with MMSE scores in more variables, including bilateral ERC thickness and hippocampal volume. GLM analysis revealed that right ERC thickness correlated significantly with MMSE score in both datasets. Cortical thicknesses of the left parahippocampal gyrus, left inferior parietal lobe, and right fusiform gyrus also significantly correlated with MMSE score in the ADNI dataset (p < 0.05). CONCLUSION: A positive correlation between right ERC thickness and MMSE score was identified from multi-country datasets.


Asunto(s)
Enfermedad de Alzheimer , Corteza Entorrinal , Enfermedad de Alzheimer/diagnóstico por imagen , Corteza Entorrinal/diagnóstico por imagen , Femenino , Hipocampo , Humanos , Imagen por Resonancia Magnética , Masculino , Lóbulo Temporal
3.
Eur J Radiol Open ; 8: 100359, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34095357

RESUMEN

PURPOSE: The early detection of cognitive function decline is crucial to help manage or slow the progression of symptoms. The Mini-Mental State Examination (MMSE) and revised Hasegawa's Dementia Scale (HDS-R) are widely used in screening for cognitive impairment. The purpose of this study was to explore common predictors of the two different cognitive testing systems using MR-based brain morphometry. MATERIALS AND METHODS: This retrospective study included 200 subjects with clinical suspicion of cognitive impairment who underwent 3D T1-weighted MRI at our institution between February 2019 and August 2020. Variables related to the volume of deep gray matter and 70 cortical thicknesses were obtained from the MR images using voxel-based specific regional analysis system for Alzheimer's disease (VSRAD) and FreeSurfer software. The correlation between each variable including age and MMSE/HDS-R scores was evaluated using uni- and multi-variate logistic regression analyses. RESULTS: In univariate analysis, parameters include hippocampal volume and bilateral entorhinal cortex (ERC) thickness showed moderate correlation coefficients with both MMSE and HDS-R scores. Multivariate analysis demonstrated the right ERC thickness was the common parameter which significantly correlates with both MMSE and HDS-R scores (p < 0.05). CONCLUSION: Right ERC thickness appears to offer a useful predictive biomarker for both MMSE and HDS-R scores.

4.
Jpn J Radiol ; 39(5): 424-432, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33386574

RESUMEN

PURPOSE: To demonstrate effectiveness of our present radiological report check flowchart enabling physicians to respond to significant unexpected findings (SUFs), by comparing the response periods from the examination date to the action date on untreated SUFs between the previous and present versions of our flowchart. METHODS: In the flowchart's previous version used February-October 2019, SUFs, which were notified by email, were audited every month. The physician received a phone call and was asked to act on the untreated SUF. In the flowchart's present version used from November 2019 to May 2020, SUFs were audited every 2 weeks. The physician and his/her chief were asked to return a written response to the untreated SUF. We evaluated the difference in the response periods between the previous and present versions of the flowchart. RESULTS: With the previous flowchart's use, untreated SUFs were 43 of 229 SUFs (18.8%) with the present flowchart untreated SUFs were 22 of 130 SUFs (16.9%). All SUFs in both periods were eventually responded. The present flowchart (median/range, 25/11-70 days) significantly had shorter response periods than the previous flowchart (70/16-290 days) (p < 0.0001). CONCLUSION: The present flowchart employing a shortened primary audit interval, a written response, and the department chief's intervention, helped reduce the response periods.


Asunto(s)
Hallazgos Incidentales , Imagen por Resonancia Magnética , Sistemas de Información Radiológica , Humanos , Médicos , Estudios Retrospectivos
5.
Interv Radiol (Higashimatsuyama) ; 6(2): 51-54, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35909909

RESUMEN

Knowledge of the anatomic variations of the supraduodenal artery (SDA) and right gastric artery (RGA) is necessary to reduce the procedure time and radiation exposure dose, as well as to avoid unexpected complications of catheter placement before hepatic arterial infusion chemotherapy. The SDA and RGA most commonly arise from the gastroduodenal artery (GDA) and the proper hepatic artery, respectively; however, they can branch from the left hepatic artery (LHA). In addition, the SDA frequently anastomoses with the RGA and occasionally with the GDA. We observed a rare anatomic variant of SDA and RGA originating from the LHA as a common trunk. The patient also had a variant of SDA communicating with the GDA. It is important for interventional radiologists to be aware of these variations.

6.
Int J Cardiovasc Imaging ; 34(9): 1485-1491, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29730724

RESUMEN

To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0-2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0-4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Valor Predictivo de las Pruebas
7.
Clin Imaging ; 50: 147-156, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29482117

RESUMEN

We explored the clinical value of low-tube voltage prospective second-generation ECG-triggered 320-row CT angiography in infants with complex CHD (37 male, 23 female, aged 0-2 years). The diagnostic accuracy of 320-row CT in complex CHD was 99.4% for intracardiac cardiovascular malformations, 99.8% for extracardiac cardiovascular malformations, and 100% for other malformations. The average subjective overall image quality score for cardiac structures was 3.7 ±â€¯0.5 points. Second-generation 320-row CT angiography with low-tube voltage and prospective ECG-triggered volume target scanning allows accurate diagnosis of cardiovascular anomalies in infants with complex CHD.


Asunto(s)
Angiografía/métodos , Angiografía por Tomografía Computarizada/métodos , Cardiopatías Congénitas/diagnóstico , Corazón/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Respiración , Preescolar , Angiografía Coronaria/métodos , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Cintigrafía , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...