Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Idioma
Intervalo de año de publicación
1.
Vestn Rentgenol Radiol ; 97(5): 303-5, 2016.
Artículo en Ruso | MEDLINE | ID: mdl-30246973

RESUMEN

A clinical observation of focal accumulation of 99(m)Tc-pyrophosphate in aortic aneurysm, simulating skeletal pathology of the lumbar vertebra in planar scintigraphy mode, is presented. Additional single-photon emission computed tomography combined with computed tomography-something view allowed to confirm that the radiotracer uptake focus was localized in the distal part of the aneurysm, in the zone of lumen subocclusion by a calcified thrombus. It is suggested that the local tracer accumulation is not only due to calcification but also due to inflammatory, a factor that plays a role in the genesis of aortic aneurysm.


Asunto(s)
Aneurisma de la Aorta/patología , Pirofosfato de Tecnecio Tc 99m/farmacología , Calcificación Vascular/diagnóstico por imagen , Anciano , Artefactos , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/secundario , Femenino , Humanos , Cintigrafía/métodos , Radiofármacos/farmacología , Tomografía Computarizada por Rayos X/métodos
2.
Vestn Rentgenol Radiol ; (4): 40-4, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26552228

RESUMEN

Based on the analysis of the data available in the literature and own clinical observations, the authors consider the diagnostic value of the little known scintigraphic phantom kidney phenomenon, a vascular pool that is detected at the angiographic stage of 99mTc-DTPA dynamic renal scintigraphy and that mimics a removed or absent kidney. The paper describes two cases of the phantom kidney. In one case, the phantom kidney detected on the side of nephrectomy manifested a kidney cancer recurrence in the bed of the removed organ; in the other, the kidney-like vascular pool in the patient with left-sided pelvic dystopic kidney was due to the recording of the intestinal vasculature at the site of the expected kidney location. Adherence to a number of methodical conditions for conducting a study, as well as combined single-photon emission computed tomography/computed tomography examination will be able to avoid interpretation errors and to ensure an adequate further diagnostic algorithm.


Asunto(s)
Errores Diagnósticos/prevención & control , Neoplasias Renales , Recurrencia Local de Neoplasia/diagnóstico , Nefrectomía/efectos adversos , Anciano , Humanos , Neoplasias Renales/patología , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Nefrectomía/métodos , Angiografía por Radionúclidos/métodos
3.
Ter Arkh ; 84(8): 78-80, 2012.
Artículo en Ruso | MEDLINE | ID: mdl-22994096

RESUMEN

Increased cardiovascular morbidity and mortality in patients with rheumatoid arthritis (RA) may be attributed to the fact that a systemic inflammation existing in this disease may trigger the development of atherosclerosis. 99mTC-MIBI (4,2-methoxyisobutyl isonitrile) is a compound that permits myocardial perfusion to be visualized and has been proposed for the evaluation of the latter in patients with RA. Analysis of the results of the studies revealed transient myocardial ischemia areas in patients who did not take methotrexate while those who used it were found to have diminished perfusion areas that were, however, clinical insignificant.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Circulación Sanguínea/fisiología , Cardiomiopatías/diagnóstico por imagen , Nitrilos , Adolescente , Adulto , Anciano , Antirreumáticos/uso terapéutico , Artritis Reumatoide/complicaciones , Artritis Reumatoide/tratamiento farmacológico , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Femenino , Humanos , Masculino , Metotrexato/uso terapéutico , Persona de Mediana Edad , Proyectos Piloto , Tomografía Computarizada de Emisión de Fotón Único , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...