Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
JACC Case Rep ; 29(3): 102182, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361568

RESUMEN

A 68-year-old woman presented with an incidentally found intracardiac mass. Transesophageal echocardiography (TEE) showed a 26 × 8 mm mobile mass attached to a calcified posterolateral mitral annulus. The mass was removed with a commercially available percutaneous catheter system using cerebral embolic protection and TEE guidance. The pathologic examination showed caseous mitral annular calcification.

3.
Ann Card Anaesth ; 26(1): 83-85, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36722593

RESUMEN

Although rare, iatrogenic aortocoronary arteriovenous fistulae (ACAVF) occur when a coronary graft is mistakenly anastomosed to an epicardial vein rather than its intended arterial target. Patients may be asymptomatic, demonstrate angina, dyspnea, arrhythmias, syncope, or diminished exercise capacity, and may have wide pulse pressures with evidence of coronary steal. A thorough insight into the disordered anatomy is critical to safely manage a patient for redo cardiac surgery, especially when attempting to arrest the heart. We present a case for redo cardiac surgery of an iatrogenic ACAVF confirmed perioperatively with multiple modalities and its intraoperative management.


Asunto(s)
Fístula Arteriovenosa , Procedimientos Quirúrgicos Cardíacos , Humanos , Puente de Arteria Coronaria , Corazón , Angina de Pecho , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/etiología , Fístula Arteriovenosa/cirugía
5.
Heart Lung Circ ; 31(8): 1166-1175, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35339372

RESUMEN

OBJECTIVES: The clinical implications of finding immobile leaflet(s) at the time of bioprosthetic valve implantation but with acceptable prosthetic haemodynamics are uncertain. We sought to determine the characteristics of such patients and their impact on outcome. METHODS: Patients with immobile leaflet at the time of surgical bioprosthetic valve implantation were identified retrospectively by a systematic search of an institutional echocardiography database (2010-2020). Intraoperative echocardiograms were reviewed de-novo to confirm immobile leaflet(s) at the time of implantation. Cases were matched 1:2 to controls with normal bioprosthetic leaflets motion for age, sex, prosthesis position, prosthesis model, size, year of implantation, and pre-implantation left ventricular ejection fraction. Proportional hazards method was used to analyse the composite endpoint of stroke, valve thrombosis or re-intervention. RESULTS: Immobile leaflet at the time of bioprosthetic valve implantation were found in 26 patients (median age 71 ys 39% males) following tricuspid (n=13), mitral (n=11) and aortic (n=2) valve replacements; 96% received porcine prostheses; prosthesis size was 27 mm or larger in 92%. Immobile leaflet were recorded on intraoperative reports in 16 (62%) cases. It resulted in elevated gradient or mild-moderate prosthetic regurgitation in three (12%), but none led to immediate corrective action intraoperatively. At median follow-up of 21 (4-50) months, presence of immobile leaflet was associated with composite clinical endpoint of stroke, valve thrombosis or re-intervention (hazard ratio 6.8, 95% CI 1.8-25.2, p<0.01) compared to controls. CONCLUSION: Immobile leaflet immediately post-bioprosthetic valve implantation is frequently under-recognised intraoperatively and appears to be associated with early bioprosthetic dysfunction and worse clinical outcome.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Trombosis , Animales , Bioprótesis/efectos adversos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Masculino , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Volumen Sistólico , Porcinos , Trombosis/etiología , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Curr Cardiol Rep ; 22(8): 60, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32562136

RESUMEN

PURPOSE OF REVIEW: This review summarizes the optimal techniques for the performance of pericardiocentesis in contemporary practice, highlighting the indications, contraindications, and techniques used. Routine pericardial catheter management and the diagnostic role of pericardial fluid analysis are described. RECENT FINDINGS: Echocardiographic-guided pericardiocentesis should be considered the therapy of choice in current clinical practice and may be performed safely despite the presence of coagulopathy and thrombocytopenia in the hands of expert operators. Computed tomography (CT)-guided techniques may provide a useful adjunctive tool in patients with poor acoustic windows or complex loculated effusions. Conservative management utilizing pericardiocentesis may be considered in select patients with device lead and interventional-related pericardial effusions. Echocardiographic-guided pericardiocentesis with extended pericardial drainage (goal output < 50 mL/24 h) should be considered the standard of care in contemporary practice. Pericardial fluid analysis should be tailored based on the clinical history and appearances of the pericardial fluid.


Asunto(s)
Taponamiento Cardíaco , Derrame Pericárdico , Ecocardiografía , Humanos , Pericardiocentesis , Pericardio
8.
Open Forum Infect Dis ; 7(3): ofaa069, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32211446

RESUMEN

BACKGROUND: The American Heart Association (AHA) guidelines for infective endocarditis (IE) management recommend end-of-therapy (EOT) echocardiography (ETE) to "establish a new baseline" and based on "expert opinion." METHODS: Medical records of IE patients treated between January 2005 and December 2011 were reviewed. Utilization of ETE and cumulative incidence of re-treatment with antimicrobials or cardiovascular surgery (re-Rx/CVS) within 1 year after EOT were evaluated. RESULTS: A total of 243 patients completed clinical follow-up at EOT and 170 at 1 year after EOT. One hundred seventy-seven of 243 (72.8%) underwent ETE, the majority (51.4%) transthoracic echocardiography. One hundred thirty-three of 177 (75.1%) were without new/worsened signs or symptoms (new/w-SSx). One hundred forty-one of 177 (79.7%) overall and 117/133 (87.9%) patients without new/w-SSx had no new ETE findings as compared with initial echocardiography. Among 36/177 (20.3%) with new ETE findings, 20/36 (55.6%) had new/w-SSx; ETE findings were more likely in patients with new/w-SSx (39.2% vs 8.3%; P < 0.001) at EOT. Patients were at increased risk of re-Rx/CVS with either new ETE findings (hazard ratio [HR], 25.86; 95% confidence interval [CI], 7.64-87.56; P < .001) or new/w-SSx (HR, 5.35; 95% CI, 2.87-9.95; P < .001). The highest risk of re-Rx/CVS was in patients with both new/w-SSx and new ETE findings (HR, 45.94; 95% CI, 19.07-110.71). Conversely, only 7/187 (3.4%) patients without new/w-SSx who had an ETE required re-Rx/CVS. CONCLUSIONS: The majority of patients without new/w-SSx at EOT will not have new ETE findings or need re-Rx/CVS within 1 year after EOT. EOT new/w-SSx is associated with new ETE findings and predicts the need for re-Rx/CVS. Further study is needed to determine whether patients without new/w-SSx need ETE.

10.
Am Heart J ; 215: 12-19, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31260901

RESUMEN

Prior studies have demonstrated that the cardiac intensive care unit (CICU) patient population has evolved over time. We sought to describe the temporal changes in comorbidities, illness severity, diagnoses, procedures and adjusted mortality within our CICU practice in recent years. METHODS: We retrospectively reviewed unique CICU admissions at the Mayo Clinic from January 2007 to April 2018. Comorbidities, severity of illness scores, discharge diagnosis codes and CICU procedures and therapies were recorded, and temporal trends were assessed using linear regression and Cochran-Armitage trend tests. Trends in adjusted hospital mortality over time were assessed using multivariable logistic regression. RESULTS: We included 12,418 patients with a mean age of 67.6 years (including 37.7% females). Temporal trends in the prevalence of several comorbidities and discharge diagnoses were observed, reflecting an increase in the prevalence of non-coronary cardiovascular diseases, critical care diagnoses, and organ failure (all P ≪ .05). The use of several CICU therapies and procedures increased over time, including mechanical ventilation, invasive lines and vasoactive drugs (all P ≪ .05). A temporal decrease in adjusted hospital mortality was observed among the subgroup of patients with (adjusted OR per year 0.97, 95% CI 0.94-0.99, P = .023) and without (adjusted OR per year 0.91, 95% CI 0.85-0.96, P = .002) a critical care discharge diagnosis. CONCLUSIONS: We observed an increasing prevalence of critical care and organ failure diagnoses as well as increased utilization of critical care therapies in this CICU cohort, associated with a decrease in risk-adjusted hospital mortality over time.


Asunto(s)
Enfermedades Cardiovasculares , Unidades de Cuidados Coronarios , Cuidados Críticos , Enfermedad Crítica , Anciano , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/terapia , Comorbilidad , Unidades de Cuidados Coronarios/estadística & datos numéricos , Unidades de Cuidados Coronarios/tendencias , Cuidados Críticos/métodos , Cuidados Críticos/estadística & datos numéricos , Resultados de Cuidados Críticos , Enfermedad Crítica/mortalidad , Enfermedad Crítica/terapia , Técnicas de Diagnóstico Cardiovascular/clasificación , Femenino , Humanos , Masculino , Mortalidad/tendencias , Aceptación de la Atención de Salud/estadística & datos numéricos , Prevalencia , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estados Unidos/epidemiología
11.
Echocardiography ; 36(7): 1397-1400, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31209920

RESUMEN

We describe a case of a mass-like echocardiographic density on a mechanical prosthetic aortic valve. We initially suspected a thrombus vs vegetation on transthoracic echocardiography, but after transesophageal echocardiography, the density was subsequently determined to be cavitation by reviewing the initial images in slow motion.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Ecocardiografía/métodos , Prótesis Valvulares Cardíacas , Microburbujas , Trombosis Coronaria/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico
12.
Eur Heart J Cardiovasc Imaging ; 20(3): 298-306, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29982372

RESUMEN

AIMS: To review 2D and Doppler findings in patients diagnosed with effusive-constrictive pericarditis (ECP) and compare these to patients with cardiac tamponade and patients with surgically-proven constrictive pericarditis (CP). METHODS AND RESULTS: We identified 22 patients diagnosed with ECP at Mayo Clinic, MN, USA between 2002 and 2016 who had persistent elevation of jugular venous pressure post-pericardiocentesis. We compared them to 30 patients with CP and 30 patients with cardiac tamponade who had normalization of venous pressure post-pericardiocentesis. All patients were in sinus rhythm. Mean age was 57 ± 18 years in the ECP group; 36% were females. Most ECP and cardiac tamponade cases were idiopathic (41% and 33%, respectively). Prior to pericardiocentesis, medial and lateral e' velocities were higher in ECP compared with tamponade; both ECP and tamponade patients had markedly decreased hepatic vein diastolic forward flow velocities. Inspiratory and expiratory mitral E/A ratios were higher in ECP compared with tamponade, but lower than those observed in CP. Post-pericardiocentesis, hepatic vein diastolic forward flow velocities increased in both ECP and tamponade. Hepatic vein diastolic reversal velocities decreased in tamponade but were unchanged in ECP. During median follow-up of 481 days, three patients required pericardiectomy for CP; they were all in the ECP group (14% of ECP cases). CONCLUSION: ECP may have unique echo-Doppler features that distinguish it from both CP and tamponade. Our findings suggest that ECP could be diagnosed by echocardiography even prior to pericardiocentesis. ECP appears to have a good prognosis, particularly in patients presenting acutely.


Asunto(s)
Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/cirugía , Ecocardiografía Doppler/métodos , Pericarditis Constrictiva/diagnóstico por imagen , Pericarditis Constrictiva/cirugía , Centros Médicos Académicos , Anciano , Taponamiento Cardíaco/fisiopatología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardiectomía/métodos , Pericardiocentesis/métodos , Pericarditis Constrictiva/fisiopatología , Cuidados Posoperatorios/métodos , Cuidados Preoperatorios , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Resultado del Tratamiento
16.
Acute Card Care ; 18(1): 25-27, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27754701
18.
J Interv Card Electrophysiol ; 46(3): 237-43, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26898212

RESUMEN

INTRODUCTION: Cardiac implantable electronic device (CIED) leads frequently develop echogenic masses. However, the nature of these masses is not well understood. In patients in whom atrial fibrillation (AF) catheter ablation is planned, there is concern that transseptal puncture may result in cerebrovascular embolism of these masses. The optimal therapeutic strategy in this setting remains undefined. METHODS: We describe six patients identified over a 6-year period (2008-2014) with device lead-based masses prior to or at the time of AF ablation. We examined the anticoagulation strategy and periprocedural management based on mass identification. RESULTS: In all six patients (age 39-73; four males), the device lead mass was found in the right atrium. The average mass size was 11 ± 1.3 mm. The majority of patients were already on anticoagulation (5/6; 83 %), and an intensified anticoagulation regimen was initiated (INR goal 3.0). In all six patients, the size of the device lead mass decreased on repeat imaging. In two sixths (33 %) patients, the lead-based mass completely resolved within 2 months. The remaining four patients had persistent lead-based masses (average follow-up of 10.9 ± 9.6 months). DISCUSSION: We describe a series of patients with CIED lead-based masses found at the time of ablation. These cases illustrate that lead-based masses can disappear while patients are on high-intensity anticoagulation, most compatible with a thrombotic origin. These early data will need to be assessed in larger cohorts for further validation and evaluation of safety.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrodos Implantados/efectos adversos , Trombosis/etiología , Trombosis/prevención & control , Adulto , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Estudios de Casos y Controles , Desfibriladores Implantables/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Atención Perioperativa/métodos , Premedicación/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...