Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 109: 465-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27358946

RESUMEN

The European Union published in 2013 a new Drinking Water Directive with stricter requirements for measuring natural radioactivity. In order to adhere to this, a method for sequential separation of 210Pb, 210Po, 238U and 234U in drinking water was applied using UTEVA® and Sr resins. Polonium-210, 238U and 234U were quantified using alpha-particle spectrometry and 210Pb using liquid scintillation counting. Radium-226 and 228Ra were determined using 3M Empore Radium RAD Disks, and their quantification was done using a Quantulus™ 1220 liquid scintillation counter.


Asunto(s)
Agua Potable/análisis , Agua Potable/normas , Monitoreo del Ambiente/normas , Monitoreo de Radiación/normas , Radioisótopos/análisis , Contaminantes Radiactivos del Agua/análisis , Unión Europea , Adhesión a Directriz , Guías como Asunto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Appl Radiat Isot ; 66(10): 1307-12, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18455924

RESUMEN

In this work, a comparative study of neutron activation analysis (NAA) was performed by the nuclear institutes: CDTN/CNEN-Brazil, CCHEN-Chile and the SCK.CEN-Belgium aiming to investigate some generic, manipulated and reference medicines largely commercialized in Brazil. Some impurities such as: As, Ba, Br, Ce, Co, Cr, Eu, Fe, Hf, Sb, Sc, Sm, Ti and Zn were found, and the heterogeneity of the samples pointed out the lack of an efficient public system of quality control.


Asunto(s)
Evaluación de Medicamentos/métodos , Evaluación de Medicamentos/normas , Medicamentos Genéricos/análisis , Medicamentos Genéricos/normas , Análisis de Activación de Neutrones/métodos , Análisis de Activación de Neutrones/normas , Brasil , Valores de Referencia
4.
Eur J Clin Chem Clin Biochem ; 35(8): 603-7, 1997 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9298350

RESUMEN

It has been shown that benzethonium chloride produces linear mixed-type inhibition of choline esterase and acetylcholine esterase. These enzymes also show-reagent-carry-over inhibition if the enzyme activities are measured in plastic cuvettes in which previously protein has been determined by the alkaline benzethonium chloride method. Choline esterase is about 10-fold more sensitive to benzethonium chloride than acetylcholine esterase. With acetylthiocholine as substrate Michaelis-Menten constants for choline esterase and acetylcholine esterase are 85 mumol/l and 102 mumol/l, respectively. Carry-over inhibitory effect of benzethonium chloride can be avoided by washing the cuvettes, after protein determination by the benzethonium chloride method, with 5 ml/l Triton X-100, 5 ml/l Tween 20 or 10 g/l sodium dodecyl sulphate. The latter has a disadvantage in that it precipitates out at low temperatures. The dry slide method (Johnson & Johnson) for serum choline esterase is free of the inhibitory effect until the concentration of benzethonium chloride in the sample reaches about 200 mumol/l.


Asunto(s)
Acetilcolinesterasa/efectos de los fármacos , Bencetonio/farmacología , Inhibidores de la Colinesterasa/farmacología , Colinesterasas/efectos de los fármacos , Acetilcolinesterasa/metabolismo , Bencetonio/efectos adversos , Butiriltiocolina/metabolismo , Inhibidores de la Colinesterasa/efectos adversos , Colinesterasas/metabolismo , Humanos , Indicadores y Reactivos/efectos adversos , Cinética , Especificidad por Sustrato
5.
Clin Chem ; 41(4): 609-14, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7720254

RESUMEN

Phosphate concentrations were determined in 52 cases of paraproteinemia. The unmodified acidic ammonium molybdate method produced 19% spuriously high results. The false increase of phosphate concentration was attributable to formation of precipitate in the reaction mixture. The precipitate was formed by interaction between immunoglobulins and the unmodified acidic ammonium molybdate reagent. The magnitude of interference bore no relation to the type, concentrations, or isoelectric point of the paraproteins or to the presence or absence of free light chains. Diluting the sample to approximately 40 g/L total protein reduced but did not always eliminate the interference. In some cases paraprotein concentration as low as 8 g/L falsely increased plasma phosphate results. Apparently, only IgG and IgM but not IgA paraproteins produced the interference. Deproteination by ultrafiltration or by treatment with trichloroacetic acid removed the interference. The Kodak slide method and the new modified Boehringer Mannheim phosphate test were found to be interference-free. However, in some cases the latter new formulation is sensitive to substantial changes in ionic concentration of the reaction mixture.


Asunto(s)
Molibdeno , Paraproteinemias/sangre , Fosfatos/sangre , Sulfato de Amonio , Precipitación Química , Detergentes , Reacciones Falso Positivas , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Focalización Isoeléctrica , Mieloma Múltiple/sangre , Cloruro de Sodio/farmacología , Ácido Tricloroacético , Ultrafiltración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...