Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Open Res Eur ; 2: 26, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37645299

RESUMEN

This study aims to propose methods for identifying entrepreneurial discovery processes with weak/strong signals of technological changes and incorporating technology foresight in the design and planning of the Smart Specialization Strategy (S3). For this purpose, we first analyse patent abstracts from 2000 to 2009, obtained from the European Patent Office and use a keyword-based text mining approach to collect weak and strong technology signals; the word2vec algorithm is also employed to group weak signal keywords. We then utilize Correlation Explanation (CorEx) topic modelling to link technology weak/strong signals to invention activities for the period 2010-2018 and use the ANOVA statistical method to examine the relationship between technology weak/strong signals and patent values. The results suggest that patents related to weak rather than strong signals are more likely to be high-impact innovations and to serve as a basis for future technological developments. Furthermore, we use latent Dirichlet allocation (LDA) topic modelling to analyse patent activities related to weak/strong technology signals and compute regional topic weights. Finally, we present implications of the research.

2.
Open Res Eur ; 2: 25, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37645343

RESUMEN

Coopetition is considered an important strategy for innovation. However, the literature provides limited evidence on how coopetition relates to innovation in service sector, particularly in emerging markets. Moreover, little is known about the effects of the formal and informal aspects of coopetition on innovation and how absorptive capacity of firm may influence this relationship. Against this background, using the official national innovation surveys of Nigeria (2008 and 2011), this study contributes to the ongoing debate by empirically examining the innovation endeavors of 421 Nigerian SMEs. The study employs logistic regression methods to model and explore the relationships between coopetition and innovation in the sample. The results show that that formal coopetition hinders innovation while informal coopetition supports it and absorptive capacity moderates these relationships. The study provides important insights about the concept of coopetition in emerging markets, especially vis-à-vis their institutional idiosyncrasies. Finally, the study highlights its implications and suggests some avenues for future research.

3.
Arch Gynecol Obstet ; 305(5): 1343-1352, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34734326

RESUMEN

PURPOSE: The aim of the present study is to investigate the prognostic significance of nutritional risk factors and sarcopenia on the outcome of patients with recurrent gynaecological malignancies treated by pelvic exenteration. METHODS: We retrospectively evaluated muscle body composite measurements based on pre-operative CT scans, nutritional risk factors as assessed by a validated pre-operative questionnaire, and clinical-pathological parameters in 65 consecutive patients with recurrent gynaecological malignancies, excluding ovarian cancer, treated by pelvic exenteration at the Royal Marsden Hospital London. Predictive value for postoperative morbidity was investigated by logistic regression analyses. Relevant parameters were included in uni- and multivariate survival analyses. RESULTS: We found only (1) low muscle attenuation (MA)-an established factor for muscle depletion-and (2) moderate risk for malnutrition to be independently associated with shorter overall survival (p = 0.006 and p = 0.008, respectively). MA was significantly lower in overweight and obese patients (p = 0.04). Muscle body composite measurements were not predictive for post-operative morbidity. CONCLUSION: The study suggests that pre-operative low MA and moderate risk for malnutrition are associated with shorter survival in patients with recurrent gynaecological malignancies treated with pelvic exenteration. Further studies are needed to validate these findings in larger cohorts.


Asunto(s)
Neoplasias de los Genitales Femeninos , Desnutrición , Neoplasias Ováricas , Exenteración Pélvica , Sarcopenia , Carcinoma Epitelial de Ovario/cirugía , Enfermedad Crónica , Femenino , Neoplasias de los Genitales Femeninos/complicaciones , Neoplasias de los Genitales Femeninos/cirugía , Humanos , Desnutrición/etiología , Recurrencia Local de Neoplasia/patología , Neoplasias Ováricas/cirugía , Estudios Retrospectivos , Factores de Riesgo , Sarcopenia/complicaciones
4.
Br J Radiol ; 94(1120): 20201423, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33586998

RESUMEN

OBJECTIVE: We determined the sensitivity and specificity of multiparametric magnetic resonance imaging (MP-MRI) in detection of locally recurrent prostate cancer and extra prostatic extension in the post-radical radiotherapy setting. Histopathological reference standard was whole-mount prostatectomy specimens. We also assessed for any added value of the dynamic contrast enhancement (DCE) sequence in detection and staging of local recurrence. METHODS: This was a single centre retrospective study. Participants were selected from a database of males treated with salvage prostatectomy for locally recurrent prostate cancer following radiotherapy. All underwent pre-operative prostate-specific antigen assay, positron emission tomography CT, MP-MRI and transperineal template prostate mapping biopsy prior to salvage prostatectomy. MP-MRI performance was assessed using both Prostate Imaging-Reporting and Data System v. 2 and a modified scoring system for the post-treatment setting. RESULTS: 24 patients were enrolled. Using Prostate Imaging-Reporting and Data System v. 2, sensitivity, specificity, positive predictive value and negative predictive value was 64%, 94%, 98% and 36%. MP-MRI under staged recurrent cancer in 63%. A modified scoring system in which DCE was used as a co-dominant sequence resulted in improved diagnostic sensitivity (61%-76%) following subgroup analysis. CONCLUSION: Our results show MP-MRI has moderate sensitivity (64%) and high specificity (94%) in detecting radio-recurrent intraprostatic disease, though disease tends to be under quantified and under staged. Greater emphasis on dynamic contrast images in overall scoring can improve diagnostic sensitivity. ADVANCES IN KNOWLEDGE: MP-MRI tends to under quantify and under stage radio-recurrent prostate cancer. DCE has a potentially augmented role in detecting recurrent tumour compared with the de novo setting. This has relevance in the event of any future modified MP-MRI scoring system for the irradiated gland.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica/métodos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/cirugía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Anciano , Humanos , Masculino , Persona de Mediana Edad , Próstata/diagnóstico por imagen , Próstata/cirugía , Prostatectomía , Neoplasias de la Próstata/radioterapia , Estudios Retrospectivos , Terapia Recuperativa , Sensibilidad y Especificidad
5.
J Community Hosp Intern Med Perspect ; 10(3): 224-228, 2020 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-32850069

RESUMEN

BACKGROUND: The Brugada pattern is identified on the EKG by a coved ST-segment elevation accompanied by a negative T wave in the early precordial leads in the absence of a cardiac structural abnormality. Brugada pattern and Brugada syndrome should be differentiated, as the latter is associated with an increased risk of sudden cardiac death. METHODS: The literature was searched using multiple databases to identify all the articles on Brugada pattern. Data were screened and analyzed by independent authors. RESULTS: Sixty articles, comprising 71 patients, were included in the study. The mean age of patients was 42.6 years, with a higher prevalence of Brugada pattern in men (83%) than women (17%). The most frequent findings associated with Brugada pattern was fever (83%). Other less common presentations included cough (21%), sore throat (10%), syncope (18%), abdominal pain (8%), and chest pain (7%). Comorbidities included pneumonia (30%), upper respiratory tract infections (14%) and smoking (14%). Among treatment modalities, 39% of patients had ICD placement performed, 44% received antibiotics, while 14% had supportive care. Adenosine was given to 3% of patients, while other antiarrhythmics like milrinone, amiodarone, sotalol, procainamide, flecainide, and nitroglycerin were given to 1% of patients. Most patients with Brugada syndrome had a satisfactory outcome, with only 4% mortality rate(WHAT ABOUT THE OTHER 11%?). Out of the 71 patients, 3% had persistent Brugada patterns, while 86% of patients recovered completely. There was no significant effect of ICD on mortality or Brugada pattern resolution (p 0.37). CONCLUSION: Our study shows that fever is the main reason for unmasking the Brugada pattern in patients with this channelopathy. ICD placement in such patients is not recommended as it has no mortality benefits.

6.
Neth Heart J ; 28(Suppl 1): 25-30, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32780328

RESUMEN

In recognition of the increasing health burden of cardiovascular disease, the Dutch CardioVascular Alliance (DCVA) was founded with the ambition to lower the cardiovascular disease burden by 25% in 2030. To achieve this, the DCVA is a platform for all stakeholders in the cardiovascular field to align policies, agendas and research. An important goal of the DCVA is to guide and encourage young researchers at an early stage of their careers in order to help them overcome challenges and reach their full potential. Young@Heart is part of the DCVA that supports the young cardiovascular research community. This article illustrates the challenges and opportunities encountered by young cardiovascular researchers in the Netherlands and highlights Young@Heart's vision to benefit from these opportunities and optimise collaborations to contribute to lowering the cardiovascular disease burden together as soon as possible.

7.
J Med Genet ; 57(4): 226-236, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31719169

RESUMEN

BACKGROUND: Germline TP53 gene pathogenic variants (pv) cause a very high lifetime risk of developing cancer, almost 100% for women and 75% for men. In the UK, annual MRI breast screening is recommended for female TP53 pv carriers. The SIGNIFY study (Magnetic Resonance Imaging screening in Li Fraumeni syndrome: An exploratory whole body MRI) study reported outcomes of whole-body MRI (WB-MRI) in a cohort of 44 TP53 pv carriers and 44 matched population controls. The results supported the use of a baseline WB-MRI screen in all adult TP53 pv carriers. Here we report the acceptability of WB-MRI screening and effects on psychosocial functioning and health-related quality of life in the short and medium terms. METHODS: Psychosocial and other assessments were carried out at study enrolment, immediately before MRI, before and after MRI results, and at 12, 26 and 52 weeks' follow-up. RESULTS: WB-MRI was found to be acceptable with high levels of satisfaction and low levels of psychological morbidity throughout. Although their mean levels of cancer worry were not high, carriers had significantly more cancer worry at most time-points than controls. They also reported significantly more clinically significant intrusive and avoidant thoughts about cancer than controls at all time-points. There were no clinically significant adverse psychosocial outcomes in either carriers with a history of cancer or in those requiring further investigations. CONCLUSION: WB-MRI screening can be implemented in TP53 pv carriers without adverse psychosocial outcomes in the short and medium terms. A previous cancer diagnosis may predict a better psychosocial outcome. Some carriers seriously underestimate their risk of cancer. Carriers of pv should have access to a clinician to help them develop adaptive strategies to cope with cancer-related concerns and respond to clinically significant depression and/or anxiety.


Asunto(s)
Síndrome de Li-Fraumeni/diagnóstico , Imagen por Resonancia Magnética , Neoplasias/diagnóstico , Proteína p53 Supresora de Tumor/genética , Adulto , Femenino , Predisposición Genética a la Enfermedad , Mutación de Línea Germinal/genética , Heterocigoto , Humanos , Síndrome de Li-Fraumeni/diagnóstico por imagen , Síndrome de Li-Fraumeni/genética , Síndrome de Li-Fraumeni/patología , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Neoplasias/genética , Neoplasias/patología , Factores de Riesgo , Imagen de Cuerpo Entero , Adulto Joven
8.
Radiother Oncol ; 141: 181-187, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31493904

RESUMEN

BACKGROUND AND PURPOSE: To assess the diagnostic accuracy and inter-observer agreement of T2-weighted (T2W) and diffusion-weighted (DW) magnetic resonance imaging (MRI) for mapping intra-prostatic tumour lesions (IPLs) for the purpose of focal dose-escalation in prostate cancer radiotherapy. MATERIALS AND METHODS: Twenty-six men selected for radical treatment with radiotherapy were recruited prospectively and underwent pre-treatment T2W+DW-MRI and 5 mm spaced transperineal template-guided mapping prostate biopsies (TTMPB). A 'traffic-light' system was used to score both data sets. Radiologically suspicious lesions measuring ≥0.5 cm3 were classified as red; suspicious lesions 0.2-0.5 cm3 or larger lesions equivocal for tumour were classified as amber. The histopathology assessment combined pathological grade and tumour length on biopsy (red = ≥4 mm primary Gleason grade 4/5 or ≥6 mm primary Gleason grade 3). Two radiologists assessed the MRI data and inter-observer agreement was measured with Cohens' Kappa co-efficient. RESULTS: Twenty-five of 26 men had red image-defined IPLs by both readers, 24 had red pathology-defined lesions. There was a good correlation between lesions ≥0.5 cm3 classified "red" on imaging and "red" histopathology in biopsies (Reader 1: r = 0.61, p < 0.0001, Reader 2: r = 0.44, p = 0.03). Diagnostic accuracy for both readers for red image-defined lesions was sensitivity 85-86%, specificity 93-98%, positive predictive value (PPV) 79-92% and negative predictive value (NPV) 96%. Inter-observer agreement was good (Cohen's Kappa 0.61). CONCLUSIONS: MRI is accurate for mapping clinically significant prostate cancer; diffusion-restricted lesions ≥0.5 cm3 can be confidently identified for radiation dose boosting.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica
9.
JACC Clin Electrophysiol ; 5(8): 968-976, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31439299

RESUMEN

OBJECTIVES: This meta-analysis examined the ability of pulmonary vein isolation (PVI) to prevent atrial fibrillation in randomized controlled trials (RCTs) in which the patients not receiving PVI nevertheless underwent a procedure. BACKGROUND: PVI is a commonly used procedure for the treatment of atrial fibrillation (AF), and its efficacy has usually been judged against therapy with anti-arrhythmic drugs in open-label trials. There have been several RCTs of AF ablation in which both arms received an ablation, but the difference between the treatment arms was inclusion or omission of PVI. These trials of an ablation strategy with PVI versus an ablation strategy without PVI may provide a more rigorous method for evaluating the efficacy of PVI. METHODS: Medline and Cochrane databases were searched for RCTs comparing ablation including PVI with ablation excluding PVI. The primary efficacy endpoint was freedom from atrial fibrillation (AF) and atrial tachycardia at 12 months. A random-effects meta-analysis was performed using the restricted maximum likelihood estimator. RESULTS: Overall, 6 studies (n = 610) met inclusion criteria. AF recurrence was significantly lower with an ablation including PVI than an ablation without PVI (RR: 0.54; 95% confidence interval [CI]: 0.33 to 0.89; p = 0.0147; I2 = 79.7%). Neither the type of AF (p = 0.48) nor the type of non-PVI ablation (p = 0.21) was a significant moderator of the effect size. In 3 trials the non-PVI ablation procedure was performed in both arms, whereas PVI was performed in only 1 arm. In these studies, AF recurrence was significantly lower when PVI was included (RR: 0.32; 95% CI: 0.14 to 0.73; p = 0.007, I2 78%). CONCLUSIONS: In RCTs where both arms received an ablation, and therefore an expectation amongst patients and doctors of benefit, being randomized to PVI had a striking effect, reducing AF recurrence by a half.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Ablación por Catéter/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia
10.
Physiol Meas ; 40(4): 04NT01, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30933931

RESUMEN

OBJECTIVE: Optimization of cardiac resynchronization therapy using non-invasive haemodynamic parameters produces reliable optima when performed at high atrial paced heart rates. Here we investigate whether this is a result of increased heart rate or atrial pacing itself. APPROACH: Forty-three patients with cardiac resynchronization therapy underwent haemodynamic optimization of atrioventricular (AV) delay using non-invasive beat-to-beat systolic blood pressure in three states: rest (atrial-sensing, 66 ± 11 bpm), slow atrial pacing (73 ± 12 bpm), and fast atrial pacing (94 ± 10 bpm). A 20-patient subset underwent a fourth optimization, during exercise (80 ± 11 bpm). MAIN RESULTS: Intraclass correlation coefficient (ICC, quantifying information content mean ±SE) was 0.20 ± 0.02 for resting sensed optimization, 0.45 ± 0.03 for slow atrial pacing (p  < 0.0001 versus rest-sensed), and 0.52 ± 0.03 for fast atrial pacing (p  = 0.12 versus slow-paced). 78% of the increase in ICC, from sinus rhythm to fast atrial pacing, is achieved by simply atrially pacing just above sinus rate. Atrial pacing increased signal (blood pressure difference between best and worst AV delay) from 6.5 ± 0.6 mmHg at rest to 13.3 ± 1.1 mmHg during slow atrial pacing (p  < 0.0001) and 17.2 ± 1.3 mmHg during fast atrial pacing (p  = 0.003 versus slow atrial pacing). Atrial pacing reduced noise (average SD of systolic blood pressure measurements) from 4.9 ± 0.4 mmHg at rest to 4.1 ± 0.3 mmHg during slow atrial pacing (p  = 0.28). At faster atrial pacing the noise was 4.6 ± 0.3 mmHg (p  = 0.69 versus slow-paced, p  = 0.90 versus rest-sensed). In the exercise subgroup ICC was 0.14 ± 0.02 (p  = 0.97 versus rest-sensed). SIGNIFICANCE: Atrial pacing, rather than the increase in heart rate, contributes to ~80% of the observed information content improvement from sinus rhythm to fast atrial pacing. This is predominantly through increase in measured signal.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemodinámica , Anciano , Ejercicio Físico , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Descanso/fisiología , Relación Señal-Ruido , Factores de Tiempo
11.
Eur Heart J Qual Care Clin Outcomes ; 5(4): 321-333, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30715300

RESUMEN

AIMS: Right ventricular pacing for left ventricular outflow tract gradient reduction in hypertrophic obstructive cardiomyopathy remains controversial. We undertook a meta-analysis for echocardiographic and functional outcomes. METHODS AND RESULTS: Thirty-four studies comprising 1135 patients met eligibility criteria. In the four blinded randomized controlled trials (RCTs), pacing reduced gradient by 35% [95% confidence interval (CI) 23.2-46.9, P < 0.0001], but there was only a trend towards improved New York Heart Association (NYHA) class [odds ratio (OR) 1.82, CI 0.96-3.44; P = 0.066]. The unblinded observational studies reported a 54.3% (CI 44.1-64.6, P < 0.0001) reduction in gradient, which was a 18.6% greater reduction than the RCTs (P = 0.0351 for difference between study designs). Observational studies reported an effect on unblinded NYHA class at an OR of 8.39 (CI 4.39-16.04, P < 0.0001), 450% larger than the OR in RCTs (P = 0.0042 for difference between study designs). Across all studies, the gradient progressively decreased at longer follow durations, by 5.2% per month (CI 2.5-7.9, P = 0.0001). CONCLUSION: Right ventricular pacing reduces gradient in blinded RCTs. There is a non-significant trend to reduction in NYHA class. The bias in assessment of NYHA class in observational studies appears to be more than twice as large as any genuine treatment effect.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
13.
JACC Cardiovasc Imaging ; 12(8 Pt 1): 1407-1416, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-29778861

RESUMEN

OBJECTIVES: BRAVO (British Randomized Controlled Trial of AV and VV Optimization) is a multicenter, randomized, crossover, noninferiority trial comparing echocardiographic optimization of atrioventricular (AV) and interventricular delay with a noninvasive blood pressure method. BACKGROUND: Cardiac resynchronization therapy including AV delay optimization confers clinical benefit, but the optimization requires time and expertise to perform. METHODS: This study randomized patients to echocardiographic optimization or hemodynamic optimization using multiple-replicate beat-by-beat noninvasive blood pressure at baseline; after 6 months, participants were crossed over to the other optimization arm of the trial. The primary outcome was exercise capacity, quantified as peak exercise oxygen uptake. Secondary outcome measures were echocardiographic left ventricular (LV) remodeling, quality-of-life scores, and N-terminal pro-B-type natriuretic peptide. RESULTS: A total of 401 patients were enrolled, the median age was 69 years, 78% of patients were men, and the New York Heart Association functional class was II in 84% and III in 16%. The primary endpoint, peak oxygen uptake, met the criterion for noninferiority (pnoninferiority = 0.0001), with no significant difference between the hemodynamically optimized arm and echocardiographically optimized arm of the trial (mean difference 0.1 ml/kg/min). Secondary endpoints for noninferiority were also met for symptoms (mean difference in Minnesota score 1; pnoninferiority = 0.002) and hormonal changes (mean change in N-terminal pro-B-type natriuretic peptide -10 pg/ml; pnoninferiority = 0.002). There was no significant difference in LV size (mean change in LV systolic dimension 1 mm; pnoninferiority < 0.001; LV diastolic dimension 0 mm; pnoninferiority <0.001). In 30% of patients the AV delay identified as optimal was more than 20 ms from the nominal setting of 120 ms. CONCLUSIONS: Optimization of cardiac resynchronization therapy devices by using noninvasive blood pressure is noninferior to echocardiographic optimization. Therefore, noninvasive hemodynamic optimization is an acceptable alternative that has the potential to be automated and thus more easily implemented. (British Randomized Controlled Trial of AV and VV Optimization [BRAVO]; NCT01258829).


Asunto(s)
Determinación de la Presión Sanguínea , Terapia de Resincronización Cardíaca , Ecocardiografía Doppler , Insuficiencia Cardíaca/terapia , Hemodinámica , Potenciales de Acción , Anciano , Presión Sanguínea , Terapia de Resincronización Cardíaca/efectos adversos , Estudios Cruzados , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
14.
Eur Heart J ; 40(21): 1728-1738, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30226525

RESUMEN

AIMS: The provision of high-quality education allows the European Society of Cardiology (ESC) to achieve its mission of better cardiovascular practice and provides an essential component of translating new evidence to improve outcomes. METHODS AND RESULTS: The 4th ESC Education Conference, held in Sophia Antipolis (December 2016), brought together ESC education leaders, National Directors of Training of 43 ESC countries, and representatives of the ESC Young Community. Integrating national descriptions of education and cardiology training, we discussed innovative pathways to further improve knowledge and skills across different training programmes and health care systems. We developed an ESC roadmap supporting better cardiology training and continued medical education (CME), noting: (i) The ESC provides an excellent framework for unbiased and up-to-date cardiovascular education in close cooperation with its National Societies. (ii) The ESC should support the harmonization of cardiology training, curriculum development, and professional dialogue and mentorship. (iii) ESC congresses are an essential forum to learn and discuss the latest developments in cardiovascular medicine. (iv) The ESC should create a unified, interactive educational platform for cardiology training and continued cardiovascular education combining Webinars, eLearning Courses, Clinical Cases, and other educational programmes, along with ESC Congress content, Practice Guidelines and the next ESC Textbook of Cardiovascular Medicine. (v) ESC-delivered online education should be integrated into National and regional cardiology training and CME programmes. CONCLUSION: These recommendations support the ESC to deliver excellent and comprehensive cardiovascular education for the next generation of specialists. Teamwork between international, national and local partners is essential to achieve this objective.


Asunto(s)
Cardiología , Educación Médica Continua/organización & administración , Sociedades Médicas/organización & administración , Cardiología/educación , Cardiología/organización & administración , Europa (Continente) , Humanos , Guías de Práctica Clínica como Asunto
15.
J Am Coll Cardiol ; 72(24): 3112-3122, 2018 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-30545450

RESUMEN

BACKGROUND: His bundle pacing is a new method for delivering cardiac resynchronization therapy (CRT). OBJECTIVES: The authors performed a head-to-head, high-precision, acute crossover comparison between His bundle pacing and conventional biventricular CRT, measuring effects on ventricular activation and acute hemodynamic function. METHODS: Patients with heart failure and left bundle branch block referred for conventional biventricular CRT were recruited. Using noninvasive epicardial electrocardiographic imaging, the authors identified patients in whom His bundle pacing shortened left ventricular activation time. In these patients, the authors compared the hemodynamic effects of His bundle pacing against biventricular pacing using a high-multiple repeated alternation protocol to minimize the effect of noise, as well as comparing effects on ventricular activation. RESULTS: In 18 of 23 patients, left ventricular activation time was significantly shortened by His bundle pacing. Seventeen patients had a complete electromechanical dataset. In them, His bundle pacing was more effective at delivering ventricular resynchronization than biventricular pacing: greater reduction in QRS duration (-18.6 ms; 95% confidence interval [CI]: -31.6 to -5.7 ms; p = 0.007), left ventricular activation time (-26 ms; 95% CI: -41 to -21 ms; p = 0.002), and left ventricular dyssynchrony index (-11.2 ms; 95% CI: -16.8 to -5.6 ms; p < 0.001). His bundle pacing also produced a greater acute hemodynamic response (4.6 mm Hg; 95% CI: 0.2 to 9.1 mm Hg; p = 0.04). The incremental activation time reduction with His bundle pacing over biventricular pacing correlated with the incremental hemodynamic improvement with His bundle pacing over biventricular pacing (R = 0.70; p = 0.04). CONCLUSIONS: His resynchronization delivers better ventricular resynchronization, and greater improvement in hemodynamic parameters, than biventricular pacing.


Asunto(s)
Fascículo Atrioventricular , Bloqueo de Rama/complicaciones , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/complicaciones , Anciano , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
16.
BJOG ; 125(13): 1726-1733, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30099822

RESUMEN

OBJECTIVE: To determine the association between the residual cervix measured on postoperative MRI after radical vaginal trachelectomy (RVT) and adverse obstetrical outcomes. DESIGN: Observational study. SETTING: Referral Cancer centre. POPULATION: Women who conceived after RVT for cervical cancer at the Royal Marsden Hospital, London, between 1995 and 2015. METHODS: Postoperative MRI scans were analysed by three researchers. The agreement between researchers was assessed by Pearson's correlation coefficient and Bland-Altman plot. Patients were divided into two groups (<10 and ≥10 mm residual cervix) for the analysis of adverse obstetrical outcomes. MAIN OUTCOME MEASURES: Late miscarriage, premature delivery, premature rupture of membranes (PROM) and chorioamnionitis. RESULTS: Thirty-one MRI scans were available; 29 of these women had a pregnancy that progressed beyond the first trimester. There was a strong reproducibility of the measurement of residual cervix (P < 0.001). Nineteen women (65.5%) had <10 mm residual cervix and 10 (34.5%) had ≥10 mm. Among women with <10 mm residual cervix, seven (36.8%) experienced PROM and ten (66.7%) had a preterm birth; No women with ≥10 mm residual cervix had PROM and two (22.2%) had a preterm birth (P = 0.028 and P = 0.035, respectively). Overall, there were nine (16.7%) first-trimester miscarriages, six (11.1%) late fetal losses, 12 (31.6%) preterm births and 36 (66.7%) live births. After a mean follow up of 78.1 months, 36 women were disease-free and one woman had died. CONCLUSIONS: MRI measurements of the residual cervix are reproducible between observers. The incidence of PROM and premature delivery is higher when the residual cervix after RVT is <10 mm. TWEETABLE ABSTRACT: The risk of prematurity after RVT can be predicted from measurements of residual cervical length on postoperative MRI scan.


Asunto(s)
Cuello del Útero/diagnóstico por imagen , Cuello del Útero/patología , Imagen por Resonancia Magnética , Traquelectomía/efectos adversos , Neoplasias del Cuello Uterino/cirugía , Aborto Espontáneo/etiología , Adulto , Cuello del Útero/cirugía , Corioamnionitis/etiología , Femenino , Preservación de la Fertilidad , Rotura Prematura de Membranas Fetales/etiología , Edad Gestacional , Humanos , Variaciones Dependientes del Observador , Tamaño de los Órganos , Embarazo , Resultado del Embarazo , Nacimiento Prematuro/etiología , Reproducibilidad de los Resultados , Factores de Riesgo , Adulto Joven
17.
Arrhythm Electrophysiol Rev ; 7(2): 103-110, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29967682

RESUMEN

Biventricular pacing has revolutionised the treatment of heart failure in patients with sinus rhythm and left bundle branch block; however, left ventricular-lead placement is not always technically possible. Furthermore, biventricular pacing does not fully normalise ventricular activation and, therefore, the ventricular resynchronisation is imperfect. Right ventricular pacing for bradycardia may cause or worsen heart failure in some patients by causing dyssynchronous ventricular activation. His bundle pacing activates the ventricles via the native His-Purkinje system, resulting in true physiological pacing, and, therefore, is a promising alternate site for pacing in bradycardia and traditional CRT indications in cases where it can overcome left bundle branch block. Furthermore, it may open up new indications for pacing therapy in heart failure, such as targeting patients with PR prolongation, but a narrow QRS duration. In this article we explore the physiology, technology and potential roles of His bundle pacing in the prevention and treatment of heart failure.

18.
Artículo en Inglés | MEDLINE | ID: mdl-29856077

RESUMEN

BACKGROUND: Controversy exists regarding how atrial activation mode and heart rate affect optimal atrioventricular (AV) delay in cardiac resynchronization therapy. We studied these questions using high-reproducibility hemodynamic and echocardiographic measurements. METHODS: Twenty patients were hemodynamically optimized using noninvasive beat-to-beat blood pressure at rest (62 ± 11 beats/min), during exercise (80 ± 6 beats/min), and at three atrially paced rates: 5, 25, and 45 beats/min above rest, denoted as Apaced,r+5 , Apaced,r+25 , and Apaced,r+45 , respectively. Left atrial myocardial motion and transmitral flow were timed echocardiographically. RESULTS: During atrial sensing, raising heart rate shortened optimal AV delay by 25 ± 6 ms (P < 0.001). During atrial pacing, raising heart rate from Apaced,r+5 to Apaced,r+25 shortened it by 16 ± 6 ms; Apaced,r+45 shortened it 17 ± 6 ms further (P < 0.001). In comparison to atrial-sensed activation, atrial pacing lengthened optimal AV delay by 76 ± 6 ms (P < 0.0001) at rest, and at ∼20 beats/min faster, by 85 ± 7 ms (P < 0.0001), 9 ± 4 ms more (P  =  0.017). Mechanically, atrial pacing delayed left atrial contraction by 63 ± 5 ms at rest and by 73 ± 5 ms (i.e., by 10 ± 5 ms more, P < 0.05) at ∼20 beats/min faster. Raising atrial rate by exercise advanced left atrial contraction by 7 ± 2 ms (P  =  0.001). Raising it by atrial pacing did not (P  =  0.2). CONCLUSIONS: Hemodynamic optimal AV delay shortens with elevation of heart rate. It lengthens on switching from atrial-sensed to atrial-paced at the same rate, and echocardiography shows this sensed-paced difference in optima results from a sensed-paced difference in atrial electromechanical delay. The reason for the widening of the sensed-paced difference in AV optimum may be physiological stimuli (e.g., adrenergic drive) advancing left atrial contraction during exercise but not with fast atrial pacing.

19.
Echocardiography ; 34(7): 956-967, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28573718

RESUMEN

BACKGROUND: Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. METHODS AND RESULTS: We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). CONCLUSION: An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame.


Asunto(s)
Ecocardiografía/métodos , Corazón/diagnóstico por imagen , Corazón/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sístole
20.
Artículo en Inglés | MEDLINE | ID: mdl-28356307

RESUMEN

BACKGROUND: The activation pattern of localized reentry (LR) in atrial tachycardia remains incompletely understood. We used the ultra-high density Rhythmia mapping system to study activation patterns in LR. METHODS AND RESULTS: LR was suggested by small rotatory activations (carousels) containing the full spectrum of the color-coded map. Twenty-three left-sided atrial tachycardias were mapped in 15 patients (age: 64±11 years). 16 253±9192 points were displayed per map, collected over 26±14 minutes. A total of 50 carousels were identified (median 2; quartiles 1-3 per map), although this represented LR in only n=7 out of 50 (14%): here, rotation occurred around a small area of scar (<0.03 mV; 12±6 mm diameter). In LR, electrograms along the carousel encompassed the full tachycardia cycle length, and surrounding activation moved away from the carousel in all directions. Ablating fractionated electrograms (117±18 ms; 44±13% of tachycardia cycle length) within the carousel interrupted the tachycardia in every LR case. All remaining carousels were pseudo-reentrant (n=43/50 [86%]) occurring in areas of wavefront collision (n=21; median 0.5; quartiles 0-2 per map) or as artifact because of annotation of noise or interpolation in areas of incomplete mapping (n=22; median 1, quartiles 0-2 per map). Pseudo-reentrant carousels were incorrectly ablated in 5 cases having been misinterpreted as LR. CONCLUSIONS: The activation pattern of LR is of small stable rotational activations (carousels), and this drove 30% (7/23) of our postablation atrial tachycardias. However, this appearance is most often pseudo-reentrant and must be differentiated by interpretation of electrograms in the candidate circuit and activation in the wider surrounding region.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Enfermedad Iatrogénica , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA