Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 198(16): 1230-1237, 2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-35863068

RESUMEN

The detailed dose analysis at the extremities remains a challenge, without affecting operators' mobility and their tactile sense. Using films loaded with optically stimulated luminescence (OSL) crystals have been studied in order to overcome some of these challenges in 2D dosimetry. In this work, we investigated flexible polymeric films loaded with MgB4O7:Ce,Li to acquire a better understanding of the dependence of the dosimetric signal characteristics on the production process and the influence of using different powder grain sizes. In film production, five different solvents were used: acetone-benzene, dichloromethane, chloroform, tetrahydrofuran and formic acid. Our results indicate that acetone-benzene is the solvent mixture that less influences the signal emitted by treated crystals, in comparison with the signal emitted by the pristine crystal powder. Conversely, by using formic acid, the crystalline structure of the sample was most severely modified, leading to a drastic reduction of the emitted OSL signal. We found that the extent of the grain surface in contact with the solvent in the process is important and should be taken into consideration when choosing the proper grain size to be used. Highlights  Polymeric films loaded with MgB4O7:Ce,Li crystals were produced using different solvents.Different effect on the OSL signal was found depending on the used solvent.Among the evaluated solvents, acetone-benzene was the one that less affected the OSL signal.


Asunto(s)
Dosimetría con Luminiscencia Ópticamente Estimulada , Acetona , Benceno , Cloroformo , Formiatos , Furanos , Luminiscencia , Cloruro de Metileno , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Polímeros , Polvos , Solventes
2.
Med Phys ; 43(2): 930-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26843253

RESUMEN

PURPOSE: This paper describes a method to achieve consistent clinical image quality in (18)F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. METHODS: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. RESULTS: The adoption of different schemes for three body mass ranges (<60 kg, 60-90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. CONCLUSIONS: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagenología Tridimensional/métodos , Imagen Multimodal , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Dosis de Radiación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA