Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Infect Control ; 25(6): 452-7, 1997 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9437482

RESUMEN

BACKGROUND: Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. METHODS: Thermal treatment of a hot water circuit was accomplished by flushing hot water (> 60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets. Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. RESULTS: Four heat-flush treatments failed to provide long-term control of L. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively. CONCLUSIONS: Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.


Asunto(s)
Infección Hospitalaria/prevención & control , Desinfección/métodos , Enfermedad de los Legionarios/prevención & control , Ingeniería Sanitaria , Abastecimiento de Agua , Cobre , Electrodos , Humanos , Iones , Legionella pneumophila/aislamiento & purificación , Servicio de Mantenimiento e Ingeniería en Hospital , Pennsylvania , Plata , Estadísticas no Paramétricas , Microbiología del Agua
2.
Appl Environ Microbiol ; 61(12): 4464-7, 1995 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16535197

RESUMEN

We evaluated the use of peptone-yeast extract (PY) medium, different strains of Hartmannella vermiformis, and gentamicin in a coculture system to improve the discrimination of virulent and avirulent strains of Legionella pneumophila. H. vermiformis ATCC 50256 was unique among four strains of H. vermiformis, in that it multiplied equally well in Medium 1034 and PY medium (Medium 1034 without fetal calf serum, folic acid, hemin, and yeast nucleic acid and with a 50% reduction of peptone). However, both a virulent strain of L. pneumophila and its avirulent derivative strain multiplied in cocultures when PY medium was used. The multiplication of this avirulent strain was greatly reduced by incorporating gentamicin (1 (mu)g/ml) into the cocultivation system. Five virulent-avirulent sets of L. pneumophila strains were then tested for multiplication in cocultures with H. vermiformis ATCC 50256 and the gentamicin-containing PY medium. Only the virulent strains multiplied. The modified cocultivation system can discriminate between virulent and avirulent strains of L. pneumophila.

3.
J Clin Microbiol ; 32(4): 1054-7, 1994 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8027309

RESUMEN

A PCR-based assay for Bordetella pertussis was inhibited by using a calcium alginate fiber-tipped swab with an aluminum shaft but not by using a Dacron fiber-tipped swab with a plastic shaft. The calcium alginate fiber component inhibited the assay following storage for less than 1 min in a suspension of 10(3) CFU of B. pertussis per ml, whereas the aluminum shaft component required storage for at least 48 h in order to cause inhibition. We recommend the Dacron swab over the calcium alginate swab for collecting specimens for testing in PCR-based assays.


Asunto(s)
Técnicas Bacteriológicas/instrumentación , Bordetella pertussis/genética , Bordetella pertussis/aislamiento & purificación , Reacción en Cadena de la Polimerasa , Alginatos , Aluminio , Secuencia de Bases , Sondas de ADN/genética , ADN Bacteriano/genética , Ácido Glucurónico , Ácidos Hexurónicos , Humanos , Datos de Secuencia Molecular , Nasofaringe/microbiología , Tereftalatos Polietilenos , Tos Ferina/diagnóstico , Tos Ferina/microbiología
4.
Appl Environ Microbiol ; 59(12): 4096-100, 1993 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16349110

RESUMEN

Hartmannella vermiformis, a common amoebal inhabitant of potable-water systems, supports intracellular multiplication of Legionella pneumophila and is probably important in the transportation and amplification of legionellae within these systems. To provide a practical guide for decontamination of potable-water systems, we assessed the chlorine and heat resistance of H. vermiformis. H. vermiformis cysts and trophozoites were treated independently with chlorine at concentrations of 2.0 to 10.0 ppm for 30 min and then cocultured with L. pneumophila. Both cysts and trophozoites were sensitive to concentrations between 2.0 and 4.0 ppm and above (trophozoites somewhat more so than cysts), and 10.0 ppm was lethal to both forms. Hartmannellae treated with chlorine up to a concentration of 4.0 ppm supported the growth of legionellae. To determine whether heat would be an effective addendum to chlorine treatment of amoebae, hartmannellae were subjected to temperatures of 55 and 60 degrees C for 30 min and alternatively to 50 degrees C followed by treatment with chlorine at a concentration of 2 ppm. Fewer than 0.05% of the amoebae survived treatment at 55 degrees C, and there were no survivors at 60 degrees C. Pretreatment at 50 degrees C appeared to make hartmannella cysts more susceptible to chlorine but did not further reduce the concentration of trophozoites.

5.
Appl Environ Microbiol ; 57(7): 1950-5, 1991 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-1892386

RESUMEN

A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.


Asunto(s)
Hartmannella/crecimiento & desarrollo , Legionella/crecimiento & desarrollo , Abastecimiento de Agua , Animales , Humanos , Cinética , Modelos Biológicos , Microbiología del Agua
7.
Appl Environ Microbiol ; 53(8): 1775-9, 1987 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-3662515

RESUMEN

Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggests that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.


Asunto(s)
Legionella/crecimiento & desarrollo , Microbiología del Agua , Hospitales , Concentración de Iones de Hidrógeno
8.
Appl Environ Microbiol ; 53(5): 979-86, 1987 May.
Artículo en Inglés | MEDLINE | ID: mdl-3606101

RESUMEN

Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs.


Asunto(s)
Legionella/crecimiento & desarrollo , Microbiología del Agua , Agua Dulce , Abastecimiento de Agua
9.
Appl Environ Microbiol ; 50(5): 1149-54, 1985 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-4091551

RESUMEN

An investigation of the chemical environment and growth of Legionella pneumophila in plumbing systems was conducted to gain a better understanding of its ecology in this habitat. Water samples were collected from hospital and institutional hot-water tanks known to have supported L. pneumophila and were analyzed for 23 chemical parameters. The chemical environment of these tanks was found to vary extensively, with the concentrations of certain metals reaching relatively high levels due to corrosion. The effect of various chemical conditions on L. pneumophila growth was then examined by observing its multiplication in the chemically analyzed hot-water tank samples after sterilization and reinoculation with L. pneumophila. L. pneumophila and associated microbiota used in these experiments were obtained from a hot-water tank. These stains were maintained in tap water and had never been passaged on agar. The results of the growth studies indicate that although elevated concentrations of a number of metals are toxic, lower levels of certain metals such as iron, zinc, and potassium enhance growth of naturally occurring L. pneumophila. Parallel observations on accompanying non-Legionellaceae bacteria failed to show the same relationship. These findings suggest that metal plumbing components and associated corrosion products are important factors in the survival and growth of L. pneumophila in plumbing systems and may also be important in related habitats such as cooling towers and air-conditioning systems.


Asunto(s)
Legionella/crecimiento & desarrollo , Metales/farmacología , Microbiología del Agua , Abastecimiento de Agua , Equipos y Suministros , Calor , Humanos , Legionella/efectos de los fármacos , Metales/análisis , Abastecimiento de Agua/análisis
10.
Appl Environ Microbiol ; 50(1): 21-6, 1985 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-3896142

RESUMEN

Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.


Asunto(s)
Cloro/farmacología , Legionella/efectos de los fármacos , Microbiología del Agua , Abastecimiento de Agua , Agar , Carbón Orgánico , Medios de Cultivo , Farmacorresistencia Microbiana , Técnica del Anticuerpo Fluorescente , Glicina , Concentración de Iones de Hidrógeno , Legionella/crecimiento & desarrollo , Legionella/aislamiento & purificación , Polimixina B , Factores de Tiempo , Vancomicina
11.
Appl Environ Microbiol ; 46(5): 1134-9, 1983 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-6360045

RESUMEN

A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.


Asunto(s)
Cloro/farmacología , Legionella/crecimiento & desarrollo , Microbiología del Agua , Abastecimiento de Agua , Relación Dosis-Respuesta a Droga , Escherichia coli/crecimiento & desarrollo , Concentración de Iones de Hidrógeno , Klebsiella pneumoniae/crecimiento & desarrollo , Legionella/efectos de los fármacos , Temperatura
SELECCIÓN DE REFERENCIAS