Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 88(12): 123508, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29289158

RESUMEN

A visible camera diagnostic has been developed to study the Helically Symmetric eXperiment (HSX) limiter plasma interaction. A straight line view from the camera location to the limiter was not possible due to the complex 3D stellarator geometry of HSX, so it was necessary to insert a mirror/lens system into the plasma edge. A custom support structure for this optical system tailored to the HSX geometry was designed and installed. This system holds the optics tube assembly at the required angle for the desired view to both minimize system stress and facilitate robust and repeatable camera positioning. The camera system has been absolutely calibrated and using Hα and C-III filters can provide hydrogen and carbon photon fluxes, which through an S/XB coefficient can be converted into particle fluxes. The resulting measurements have been used to obtain the characteristic penetration length of hydrogen and C-III species. The hydrogen λiz value shows reasonable agreement with the value predicted by a 1D penetration length calculation.

2.
Rev Sci Instrum ; 87(11): 11D606, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910364

RESUMEN

A combined IR and visible camera system [G. A. Wurden et al., "A high resolution IR/visible imaging system for the W7-X limiter," Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowband interference filters in front of the camera yielded C-III and Hα photon flux, and the filterscope system provided Hα, Hß, He-I, He-II, C-II, and visible bremsstrahlung data. The filterscopes made additional measurements of several points on the W7-X vacuum vessel to yield wall recycling fluxes. The resulting photon flux from both the visible camera and filterscopes can then be compared to an EMC3-EIRENE synthetic diagnostic [H. Frerichs et al., "Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X," Rev. Sci. Instrum. (these proceedings)] to infer both a limiter particle flux and wall particle flux, both of which will ultimately be used to infer the complete particle balance and particle confinement time τP.

3.
Rev Sci Instrum ; 87(11): 11D607, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910567

RESUMEN

A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1-4.5 MW/m2), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO's can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

4.
Rev Sci Instrum ; 87(11): 11D441, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910599

RESUMEN

Interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be a challenge since line of sight integration effects make direct interpretation in terms of quantitative, local emission strengths often impossible. The EMC3-EIRENE code-a 3D fluid edge plasma and kinetic neutral gas transport code-is a suitable tool for full 3D reconstruction of such signals. A versatile synthetic diagnostic module has been developed recently which allows the realistic 3D setup of various plasma edge diagnostics to be captured. We highlight these capabilities with two examples for Wendelstein 7-X (W7-X): a visible camera for the analysis of recycling, and a coherent-imaging system for velocity measurements.

5.
Nanotechnology ; 23(30): 305206, 2012 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-22780990

RESUMEN

Memristors are emerging as unique electrical devices with potential applications in memory, reconfigurable logic and biologically inspired computing. Due to the novelty of these devices, the complete details of their switching mechanism is not yet well established. In this work, the switching mechanism of our solution-processed titanium dioxide-based memristor is investigated by studying how variations in the device area and film thickness affect electrical behavior and correlating these behavioral changes to proposed switching mechanisms. The conduction path of the switching is also investigated through electrical characterization of devices both before and after physically cutting the devices in half, as well as through infrared imaging of the devices during operation. The results suggest that the electrical behavior of these devices is dominated by a localized, charge-based phenomenon that exhibits a dependence on device area.


Asunto(s)
Nanoestructuras/química , Nanotecnología/instrumentación , Titanio/química , Computadores Moleculares , Fenómenos Electromagnéticos , Diseño de Equipo , Nanoestructuras/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA