Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 30(13): 22730-22745, 2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-36224964

RESUMEN

The usually reported pixel resolution of single pixel imaging (SPI) varies between 32 × 32 and 256 × 256 pixels falling far below imaging standards with classical methods. Low resolution results from the trade-off between the acceptable compression ratio, the limited DMD modulation frequency, and reasonable reconstruction time, and has not improved significantly during the decade of intensive research on SPI. In this paper we show that image measurement at the full resolution of the DMD, which lasts only a fraction of a second, is possible for sparse images or in a situation when the field of view is limited but is a priori unknown. We propose the sampling and reconstruction strategies that enable us to reconstruct sparse images at the resolution of 1024 × 768 within the time of 0.3s. Non-sparse images are reconstructed with less details. The compression ratio is on the order of 0.4% which corresponds to an acquisition frequency of 7Hz. Sampling is differential, binary, and non-adaptive, and includes information on multiple partitioning of the image which later allows us to determine the actual field of view. Reconstruction is based on the differential Fourier domain regularized inversion (D-FDRI). The proposed SPI framework is an alternative to both adaptive SPI, which is challenging to implement in real time, and to classical compressive sensing image recovery methods, which are very slow at high resolutions.

2.
Opt Express ; 29(17): 26685-26700, 2021 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-34615098

RESUMEN

The speed and quality of single-pixel imaging (SPI) are fundamentally limited by image modulation frequency and by the levels of optical noise and compression noise. In an approach to come close to these limits, we introduce a SPI technique, which is inherently differential, and comprises a novel way of measuring the zeroth spatial frequency of images and makes use of varied thresholding of sampling patterns. With the proposed sampling, the entropy of the detection signal is increased in comparison to standard SPI protocols. Image reconstruction is obtained with a single matrix-vector product so the cost of the reconstruction method scales proportionally with the number of measured samples. A differential operator is included in the reconstruction and following the method is based on finding the generalized inversion of the modified measurement matrix with regularization in the Fourier domain. We demonstrate 256 × 256 SPI at up to 17 Hz at visible and near-infrared wavelength ranges using 2 polarization or spectral channels. A low bit-resolution data acquisition device with alternating-current-coupling can be used in the measurement indicating that the proposed method combines improved noise robustness with a differential removal of the direct current component of the signal.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA