1.
Anal Bioanal Chem ; 416(10): 2389-2398, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38438547

RESUMEN

The recent clinical success of messenger RNA (mRNA) technology in managing the Covid pandemic has triggered an unprecedented innovation in production and analytical technologies for this therapeutic modality. mRNA is produced by enzymatic transcription of plasmid DNA (pDNA) using polymerase in a cell-free process of in vitro transcription. After transcription, the pDNA is considered a process-related impurity and is removed from the mRNA product enzymatically, chromatographically, or by precipitation. Regulatory requirements are currently set at 10 ng of template pDNA per single human dose, which typically ranges between 30 and 100 µg. Here, we report the development of a generic procedure based on enzymatic digestion and chromatographic separation for the determination of residual pDNA in mRNA samples, with a limit of quantification of 2.3 ng and a limit of detection of less than 0.1 ng. The procedure is based on enzymatic degradation of mRNA and anion exchange HPLC separation, followed by quantification of residual pDNA with a chromatographic method that is already widely adopted for pDNA quality analytics. The procedure has been successfully applied for in-process monitoring of three model mRNAs and a self-amplifying RNA (saRNA) and can be considered a generic substitution for qPCR in mRNA in-process control analytical strategy, with added benefits that it is more cost-efficient, faster, and sequence agnostic.


Asunto(s)
ADN , ARN , Humanos , ARN Mensajero/genética , Cromatografía Líquida de Alta Presión/métodos , Plásmidos/genética , ADN/genética
2.
Biotechnol Bioeng ; 121(5): 1739-1749, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38351874

RESUMEN

High purity of plasmid DNA (pDNA), particularly in supercoiled isoform (SC), is used for various biopharmaceutical applications, such as a transfecting agent for production of gene therapy viral vectors, for pDNA vaccines, or as a precursor for linearized form that serves as a template for mRNA synthesis. In clinical manufacturing, pDNA is commonly extracted from Escherichia coli cells with alkaline lysis followed by anion exchange chromatography or tangential flow filtration as a capture step for pDNA. Both methods remove a high degree of host cell contaminants but are unable to generically discriminate between SC and open-circular (OC) pDNA isoforms, as well as other DNA impurities, such as genomic DNA (gDNA). Hydrophobic interaction chromatography (HIC) is commonly used as polishing purification for pDNA. We developed HIC-based polishing purification methodology that is highly selective for enrichment of SC pDNA. It is generic with respect to plasmid size, scalable, and GMP compatible. The technique uses ammonium sulfate, a kosmotropic salt, at a concentration selective for SC pDNA binding to a butyl monolith column, while OC pDNA and gDNA are removed in flow-through. The approach is validated on multiple adeno-associated virus- and mRNA-encoding plasmids ranging from 3 to 12 kbp. We show good scalability to at least 300 mg of >95% SC pDNA, thus paving the way to increase the quality of genomic medicines that utilize pDNA as a key raw material.


Asunto(s)
Cromatografía , ADN Superhelicoidal , ADN Superhelicoidal/genética , Plásmidos/genética , ADN , Interacciones Hidrofóbicas e Hidrofílicas , Escherichia coli/genética , ARN Mensajero
3.
Electrophoresis ; 45(5-6): 369-379, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38059740

RESUMEN

Adenoviruses are well-known viral vectors that have been previously used in gene therapy and as a vaccine-delivery vehicle for humans and animals. During the COVID-19 pandemic, it gained renewed attention, but at the same time, it raised concerns due to side effects observed with some of the resulting vaccines administered to patients. It has been indicated that these side effects might be attributed to impurities present in the final product. Therefore, constant enhancement of the vaccine purity and further improvement of impurity detection methods are needed. In this work, we showcase an example of industry-relevant adenovirus bioprocess optimization. Our data show the effect of upstream parameters on the bioburden introduced to the downstream process. We provide an example of process optimization using a combination of the PATfix analytical method, ddPCR, infectivity, total DNA, and total protein analyses to optimize cell density, multiplicity of infection, and length of production. Additionally, we provide data illustrating the robustness of the convective interaction media quaternary amine monolithic chromatography step. This anion exchange strategy was shown to remove over 99% of protein and DNA impurities, including those unable to be addressed by tangential flow filtration, while maintaining high adenovirus recoveries.


Asunto(s)
Adenoviridae , Vacunas , Animales , Humanos , Pandemias , Cromatografía por Intercambio Iónico/métodos , ADN
4.
Electrophoresis ; 44(24): 1978-1988, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37828276

RESUMEN

Messenger RNA (mRNA) has emerged as a modality with immense therapeutic potential. Recent innovations in production process of mRNA call for procedures to isolate pure mRNA drug substance (DS) with high yield, high capacity, scalability, and compatibility with GMP production systems. Novel RNA modalities, such as circular RNA (circRNA), have further driven the need for non-affinity capture possibilities which are already widely used in the biopharmaceutical industry, for example, in monoclonal antibody processing. The principle that multimodal ion exchange/hydrogen bonding chromatography can be used to separate mRNA from in vitro transcription components has recently been demonstrated. Here, we apply and refine this approach to be suitable for scalable purification of multiple mRNA constructs with sufficient yields, purity, and stability, for use in mRNA production process. Binding capacity of the PrimaS-modified monolithic chromatographic column for mRNA enabled up to 7 mg/mL product isolation in a single chromatographic run, with 98% recovery and room temperature stability of the eGFP mRNA demonstrated for up to 28 days. This approach is independent of construct size or the presence of polyadenylic acid tail and is applicable for capture of a wide variety of RNAs, including mRNA, self-amplifying RNA, circRNA, and with optimization also smaller RNAs such as transfer RNA and others.


Asunto(s)
ARN Circular , ARN , ARN Mensajero/genética , Cromatografía por Intercambio Iónico/métodos , Aniones
5.
Int J Mol Sci ; 24(18)2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37762568

RESUMEN

Messenger RNA (mRNA) is becoming an increasingly important therapeutic modality due to its potential for fast development and platform production. New emerging RNA modalities, such as circular RNA, drive the need for the development of non-affinity purification approaches. Recently, the highly efficient chromatographic purification of mRNA was demonstrated with multimodal monolithic chromatography media (CIM® PrimaS), where efficient mRNA elution was achieved with an ascending pH gradient approach at pH 10.5. Here, we report that a newly developed chromatographic material enables the elution of mRNA at neutral pH and room temperature. This material demonstrates weak anion-exchanging properties and an isoelectric point of 5.3. It enables the baseline separation of mRNA (at least up to 10,000 nucleotides (nt) in size) from parental plasmid DNA (regardless of isoform composition) with both a NaCl gradient and ascending pH gradient approach, while mRNA elution is achieved in a pH range of 5-7. In addition, the basic structure of the novel material is a chromatographic monolith, enabling convection-assisted mass transfer of large RNA molecules to and from the active surface. This facilitates the elution of mRNA in 3-7 column volumes with more than 80% elution recovery and uncompromised integrity. This is demonstrated by the purification of a model mRNA (size 995 nt) from an in vitro transcription reaction mixture. The purified mRNA is stable for at least 34 days, stored in purified H2O at room temperature.


Asunto(s)
Cromatografía , ARN Mensajero/genética , Temperatura , Plásmidos , Concentración de Iones de Hidrógeno
6.
Electrophoresis ; 44(24): 1934-1942, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37599280

RESUMEN

Preferential exclusion chromatography (PXC) sometimes described as hydrophobic interaction chromatography is a well-known, but not widely used technique for purification of Adeno-associated viruses. It employs high molarity of preferentially excluded cosolvent (salt in our case). The downside of this method is that high molarity of salt can lead to aggregation and precipitation of different compounds from the sample. In the case of viruses that are excreted to medium, the concentration of impurities is much lower compared to cell lysates, and PXC can be used as a first chromatographic, serotype independent step to concentrate and purify adeno-associated virus (AAV). Here, we explored PXC for adherent and suspension harvests using monolithic chromatographic columns (CIMmultus). Suspension extracellular adeno-associated virus, serotype 9 (AAV9) harvest had more impurities compared to adherent harvest, therefore it required higher input regarding method development. Final conditions for suspension harvest included higher molarity of binding salt and using more open channel format of chromatographic column (6 µm channel size). Vector genome analysis with droplet digital polymerase chain reaction (ddPCR) revealed 84% and 97% recovery for suspension and adherent AAV9 harvest, respectively. After PXC capture step, adherent AAV9 was purified by already described ion exchange techniques. Overall process vector genome recovery, from clarified harvest to anion exchange elution fraction, was 54% measured by ddPCR. Residual host cell DNA was measured at 40 ng per 1E13 vector genome, and empty AAV was below 5% in final anion exchange chromatography fraction.


Asunto(s)
Dependovirus , Vectores Genéticos , Cromatografía por Intercambio Iónico/métodos , Dependovirus/genética , Cromatografía en Gel , Aniones
7.
Electrophoresis ; 44(24): 1943-1952, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37603380

RESUMEN

Adeno-associated virus (AAV) vectors are crucial tools for gene therapy applications. As AAVs are administered in vivo, stringent purity requirements must be met, necessitating the development of various downstream processing strategies in accordance with regulatory guidelines. In this context, we focus on the non-affinity serotype-independent recombinant AAV (rAAV) capture step, which involves the use of Convective Interaction Media (CIM) cation-exchange SO3 monoliths. We analyzed differentially pretreated viral samples obtained from the Sf9 cell line and applied these samples to the capture SO3 chromatography step. We conducted screening experiments using CIM SO3 0.05 mL monolithic 96-well plates with buffers of varying pH, sodium chloride concentrations, and the inclusion of poloxamer 188, aiming to select the optimal binding mobile phase. Dynamic binding capacity was defined for different pretreatments and the optimal conditions were subsequently retested using the industrial purification CIMmultus line. The results demonstrated a high overall vector recovery (51%) and a significant reduction in impurities (99.98% for protein reduction and 99.25% for DNA reduction) using the selected capture step parameters, thereby confirming the successful optimization of the rAAV capture step in the downstream process using monoliths.


Asunto(s)
ADN , Cloruro de Sodio , Cromatografía por Intercambio Iónico/métodos , Línea Celular
8.
Electrophoresis ; 44(24): 1953-1966, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37271857

RESUMEN

Increased need for plasmid DNA (pDNA) with sizes above 10 kbp (large pDNA) in gene therapy and vaccination brings the need for its large-scale production with high purity. Chromatographic purification of large pDNA is often challenging due to low process yields and column clogging, especially using anion-exchanging columns. The goal of our investigation was to evaluate the mass balance and pDNA isoform composition at column outlet for plasmids of different sizes in combination with weak anion exchange (AEX) monolith columns of varying channel size (2, 3 and 6 µm channel size). We have proven that open circular pDNA (OC pDNA) isoform is an important driver of reduced chromatographic performance in AEX chromatography. The main reason for the behaviour is the entrapment of OC pDNA in chromatographic supports with smaller channel sizes. Entrapment of individual isoforms was characterised for porous beads and convective monolithic columns. Convective entrapment of OC pDNA isoform was confirmed on both types of stationary phases. Porous beads in addition showed a reduced recovery of supercoiled pDNA (on an 11.6 kbp plasmid) caused by diffusional entrapment within the porous structure. Use of convective AEX monoliths or membranes with channel diameter >3.5 µm has been shown to increase yields and prevent irreversible pressure build-up and column clogging during purification of plasmids at least up to 16 kbp in size.


Asunto(s)
Cromatografía , ADN , Plásmidos/genética , ADN/genética , ADN Superhelicoidal , Isoformas de Proteínas
9.
Electrophoresis ; 44(24): 1967-1977, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37160710

RESUMEN

High-performance liquid chromatography (HPLC)-based analytical assays are used to effectively monitor purity and quantity of plasmid DNA (pDNA) throughout the purification process. However, the phenomenon of physical entrapment of open circular (OC) isoforms pDNA inside narrow channels of chromatographic support decreases its accuracy and precision and the effect increases with pDNA size. The purpose of the study was to develop a chromatographic method for accurate analytical separation between isoforms of <16 kbp pDNA using weak anion exchanging monolithic column with large (6 µm) convective channels. Purified samples of 4.7 and 15.4 kbp large pDNA with known isoform composition were prepared and their isoforms separated in ascending salt gradient. Both OC and supercoiled (SC) isoforms were baseline separated at a flow rate below 0.5 mL min-1 in a guanidinium chloride (GdnCl) gradient with a ≥95% OC pDNA elution recovery. However, these chromatographic conditions increased 2 times the peak width for linear (LIN) pDNA isoform compared to the results using monoliths with 1.4 µm channel size. If other chaotropic agents, such as urea or thiocyanate (SCN), were added to Gdn ions, the elution volume for LIN isoform decreased. Optimization of combined GdnCl/GdnSCN gradient for pDNA elution resulted in a simple and robust chromatographic method, where OC-LIN and LIN-SC pDNA (up to 15 kbp size) were separated with resolution above 1.0 and above 2.0, respectively. The accessibility and general acceptance of anion exchange chromatography for pDNA analytics give the newly developed method a great potential for in-process control monitoring of pDNA production processes.


Asunto(s)
ADN , Plásmidos , Cromatografía Líquida de Alta Presión/métodos , Aniones , Isoformas de Proteínas
10.
Commun Biol ; 6(1): 312, 2023 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-36959410

RESUMEN

Human plasma transferrin (Tf) N-glycosylation has been mostly studied as a marker for congenital disorders of glycosylation, alcohol abuse, and hepatocellular carcinoma. However, inter-individual variability of Tf N-glycosylation is not known, mainly due to technical limitations of Tf isolation in large-scale studies. Here, we present a highly specific robust high-throughput approach for Tf purification from human blood plasma and detailed characterization of Tf N-glycosylation on the level of released glycans by ultra-high-performance liquid chromatography based on hydrophilic interactions and fluorescence detection (HILIC-UHPLC-FLD), exoglycosidase sequencing, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). We perform a large-scale comparative study of Tf and immunoglobulin G (IgG) N-glycosylation analysis in two human populations and demonstrate that Tf N-glycosylation is associated with age and sex, along with multiple biochemical and physiological traits. Observed association patterns differ compared to the IgG N-glycome corroborating tissue-specific N-glycosylation and specific N-glycans' role in their distinct physiological functions.


Asunto(s)
Inmunoglobulina G , Procesamiento Proteico-Postraduccional , Transferrina , Humanos , Glicosilación , Ensayos Analíticos de Alto Rendimiento , Inmunoglobulina G/sangre , Inmunoglobulina G/química , Transferrina/química , Transferrina/aislamiento & purificación , Polisacáridos/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA