1.
Eur Heart J Suppl ; 25(Suppl E): E17-E24, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37234235

RESUMEN

Biventricular pacing (Biv) and left bundle branch area pacing (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms of ventricular activation. This study compared ventricular activation patterns in left bundle branch block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). This was a retrospective analysis including 80 CRT patients from two centres. UHF-ECG data were obtained during LBBB, LBBAP, and Biv. Left bundle branch area pacing patients were divided into non-selective left bundle branch pacing (NSLBBP) or left ventricular septal pacing (LVSP) and into groups with V6 R-wave peak times (V6RWPT) < 90 ms and ≥ 90 ms. Calculated parameters were: e-DYS (time difference between the first and last activation in V1-V8 leads) and Vdmean (average of V1-V8 local depolarization durations). In LBBB patients (n = 80) indicated for CRT, spontaneous rhythms were compared with Biv (39) and LBBAP rhythms (64). Although both Biv and LBBAP significantly reduced QRS duration (QRSd) compared with LBBB (from 172 to 148 and 152 ms, respectively, both P < 0.001), the difference between them was not significant (P = 0.2). Left bundle branch area pacing led to shorter e-DYS (24 ms) than Biv (33 ms; P = 0.008) and shorter Vdmean (53 vs. 59 ms; P = 0.003). No differences in QRSd, e-DYS, or Vdmean were found between NSLBBP, LVSP, and LBBAP with paced V6RWPTs < 90 and ≥ 90 ms. Both Biv CRT and LBBAP significantly reduce ventricular dyssynchrony in CRT patients with LBBB. Left bundle branch area pacing is associated with more physiological ventricular activation.

2.
J Cardiovasc Electrophysiol ; 32(5): 1385-1394, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33682277

RESUMEN

BACKGROUND: Right ventricular (RV) pacing causes delayed activation of remote ventricular segments. We used the ultra-high-frequency ECG (UHF-ECG) to describe ventricular depolarization when pacing different RV locations. METHODS: In 51 patients, temporary pacing was performed at the RV septum (mSp); further subclassified as right ventricular inflow tract (RVIT) and right ventricular outflow tract (RVOT) for septal inflow and outflow positions (below or above the plane of His bundle in right anterior oblique), apex, anterior lateral wall, and at the basal RV septum with nonselective His bundle or RBB capture (nsHBorRBBp). The timings of UHF-ECG electrical activations were quantified as left ventricular lateral wall delay (LVLWd; V8 activation delay) and RV lateral wall delay (RVLWd; V1 activation delay). RESULTS: The LVLWd was shortest for nsHBorRBBp (11 ms [95% confidence interval = 5-17]), followed by the RVIT (19 ms [11-26]) and the RVOT (33 ms [27-40]; p < .01 between all of them), although the QRSd for the latter two were the same (153 ms (148-158) vs. 153 ms (148-158); p = .99). RV apical capture not only had a longer LVLWd (34 ms (26-43) compared to mSp (27 ms (20-34), p < .05), but its RVLWd (17 ms (9-25) was also the longest compared to other RV pacing sites (mean values for nsHBorRBBp, mSp, anterior and lateral wall captures being below 6 ms), p < .001 compared to each of them. CONCLUSION: RVIT pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture. However, UHF-ECG ventricular dysynchrony seen during RVIT pacing is increased compared to concomitant capture of basal septal myocytes and His bundle or proximal right bundle branch.


Asunto(s)
Ventrículos Cardíacos , Tabique Interventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Contracción Miocárdica , Tabique Interventricular/diagnóstico por imagen
3.
Heart Rhythm ; 17(4): 607-614, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31805370

RESUMEN

BACKGROUND: Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment. OBJECTIVE: The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing. METHODS: Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated. RESULTS: One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P < .001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P > .99) and was longest during myocardial capture of the para-Hisian area (37 ms; P < .001 compared to each of the other types of ventricular activation). CONCLUSION: In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.


Asunto(s)
Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Anciano , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino