Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37480877

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/epidemiología , Volumen Sistólico , Atrios Cardíacos , Implantación de Prótesis , Pronóstico
2.
JACC Cardiovasc Interv ; 15(21): 2158-2170, 2022 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-36357020

RESUMEN

BACKGROUND: Incomplete left atrial appendage (LAA) closure is an evolving topic of clinical significance and thromboembolic potential, with recent long-term studies suggesting lower cutoffs for relevant leak size. OBJECTIVES: The aim of this prospective observational study was to assess 3 different closure techniques for persistent peridevice leaks after incomplete LAA closure and compare their efficacy and safety outcomes. METHODS: We studied 160 patients (mean age 72 ± 9 years; 71% men) who underwent 1 of the 3 available modalities (detachable embolization coils, vascular plugs or septal occluders, and radiofrequency ablation) for residual central or eccentric leak closure. Both acute postprocedural success (closure or <1-mm leak at the end of the procedure) and closure at 1-year follow-up transesophageal echocardiography imaging were evaluated. RESULTS: Of 160 patients, 0.6%, 41.3%, and 58.1% had mild (1-2 mm), moderate (3-5 mm), and severe (≥5 mm) leaks, respectively. Baseline LAA closure type was 72.5% Watchman FLX, 16.3% Lariat, 5.6% surgical ligation, 1.9% AtriClip, and 1.9% Amulet. Successful closure (0- or <1-mm leak) was seen in 100% of patients in all cohorts following intervention, with overall complete closure (0-1 mm) or mild or minimal leaks (1-2 mm) on 1-year follow-up transesophageal echocardiography seen in 100% of the atrial septal occluder or vascular plug cohort, 85.9% of the coil cohort, and 83.3% of the radiofrequency ablation cohort (P < 0.001). Two patients (1.3%) experienced cardiac tamponade, and there were no deaths or other complications. CONCLUSIONS: Peridevice leaks can safely and effectively be closed using 3 different modalities depending on size and location.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Resultado del Tratamiento , Ecocardiografía Transesofágica , Cateterismo Cardíaco/efectos adversos
3.
Artículo en Inglés | MEDLINE | ID: mdl-36187938

RESUMEN

Rotating spiral waves are self-organized features in spatially extended excitable media and may play an important role in cardiac arrhythmias including atrial fibrillation (AF). In homogeneous media, spiral wave dynamics are perpetuated through spiral wave breakup, leading to the continuous birth and death of spiral waves, but have a finite probability of termination. In non-homogeneous media, however, heterogeneities can act as anchoring sources that result in sustained spiral wave activity. It is thus unclear how and if AF may terminate following the removal of putative spiral wave sources in patients. Here, we address this question using computer simulations in which a stable spiral wave is trapped by an heterogeneity and is surrounded by spiral wave breakup. We show that, following ablation of spatial heterogeneity to render that region of the medium unexcitable, termination of spiral wave dynamics is stochastic and Poisson-distributed. Furthermore, we show that the dynamics can be accurately described by a master equation using birth and death rates. To validate these predictions in vivo, we mapped spiral wave activity in patients with AF and targeted the locations of spiral wave sources using radiofrequency ablation. Targeted ablation was indeed able to terminate AF, but only after a variable delay of up to several minutes. Furthermore, and consistent with numerical simulations, termination was not accompanied by gradual temporal or spatial organization. Our results suggest that spiral wave sources and tissue heterogeneities play a critical role in the maintenance of AF and that the removal of sources results in spiral wave dynamics with a finite termination time, which could have important clinical implications.

4.
Heart Rhythm ; 18(7): 1045-1054, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33482387

RESUMEN

BACKGROUND: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial demonstrated that adding vein of Marshall (VOM) ethanol infusion to catheter ablation (CA) improves ablation outcomes in persistent atrial fibrillation (AF). There was significant heterogeneity in the impact of VOM ethanol infusion on rhythm control. OBJECTIVE: The purpose of this study was to assess the association between outcomes and (1) achievement of bidirectional perimitral conduction block and (2) procedural volume. METHODS: The VENUS trial randomized patients with persistent AF (N = 343) to CA combined with VOM ethanol or CA alone. The primary outcome (freedom from AF or atrial tachycardia [AT] lasting longer than 30 seconds after a single procedure) was analyzed by 2 categories: (1) successful vs no perimitral block and (2) high- (>20 patients enrolled) vs low-volume centers. RESULTS: In patients with perimitral block, the primary outcome was reached 54.3% after VOM-CA and 37% after CA alone (P = .01). Among patients without perimitral block, freedom from AF/AT was 34.0% after VOM-CA and 37.0% after CA (P = .583). In high-volume centers, the primary outcome was reached in 56.4% after VOM-CA and 40.2% after CA (P = .01). In low-volume centers, freedom from AF/AT was 30.77% after VOM-CA and 32.61% after CA (P = .84). In patients with successful perimitral block from high-volume centers, the primary outcome was reached in 59% after VOM-CA and 39.1% after CA (P = .01). Tests for interaction were significant (P = .002 for perimitral block and P = .04 for center volume). CONCLUSION: Adding VOM ethanol infusion to CA has a greater impact on outcomes when associated with perimitral block and performed in high-volume centers. Perimitral block should be part of the VOM procedure.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Etanol/administración & dosificación , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento , Adulto Joven
5.
JAMA ; 324(16): 1620-1628, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-33107945

RESUMEN

Importance: Catheter ablation of persistent atrial fibrillation (AF) has limited success. Procedural strategies beyond pulmonary vein isolation have failed to consistently improve results. The vein of Marshall contains innervation and AF triggers that can be ablated by retrograde ethanol infusion. Objective: To determine whether vein of Marshall ethanol infusion could improve ablation results in persistent AF when added to catheter ablation. Design, Setting, and Participants: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial was an investigator-initiated, National Institutes of Health-funded, randomized, single-blinded trial conducted in 12 centers in the United States. Patients (N = 350) with persistent AF referred for first ablation were enrolled from October 2013 through June 2018. Follow-up concluded in June 2019. Interventions: Patients were randomly assigned to catheter ablation alone (n = 158) or catheter ablation combined with vein of Marshall ethanol infusion (n = 185) in a 1:1.15 ratio to accommodate for 15% technical vein of Marshall ethanol infusion failures. Main Outcomes and Measures: The primary outcome was freedom from AF or atrial tachycardia for longer than 30 seconds after a single procedure, without antiarrhythmic drugs, at both 6 and 12 months. Outcome assessment was blinded to randomization treatment. There were 12 secondary outcomes, including AF burden, freedom from AF after multiple procedures, perimitral block, and others. Results: Of the 343 randomized patients (mean [SD] age, 66.5 [9.7] years; 261 men), 316 (92.1%) completed the trial. Vein of Marshall ethanol was successfully delivered in 155 of 185 patients. At 6 and 12 months, the proportion of patients with freedom from AF/atrial tachycardia after a single procedure was 49.2% (91/185) in the catheter ablation combined with vein of Marshall ethanol infusion group compared with 38% (60/158) in the catheter ablation alone group (difference, 11.2% [95% CI, 0.8%-21.7%]; P = .04). Of the 12 secondary outcomes, 9 were not significantly different, but AF burden (zero burden in 78.3% vs 67.9%; difference, 10.4% [95% CI, 2.9%-17.9%]; P = .01), freedom from AF after multiple procedures (65.2% vs 53.8%; difference, 11.4% [95% CI, 0.6%-22.2%]; P = .04), and success achieving perimitral block (80.6% vs 51.3%; difference, 29.3% [95% CI, 19.3%-39.3%]; P < .001) were significantly improved in vein of Marshall-treated patients. Adverse events were similar between groups. Conclusions and Relevance: Among patients with persistent AF, addition of vein of Marshall ethanol infusion to catheter ablation, compared with catheter ablation alone, increased the likelihood of remaining free of AF or atrial tachycardia at 6 and 12 months. Further research is needed to assess longer-term efficacy. Trial Registration: ClinicalTrials.gov Identifier: NCT01898221.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Etanol/administración & dosificación , Vena Cava Superior , Anciano , Terapia Combinada/métodos , Femenino , Humanos , Infusiones Intravenosas/efectos adversos , Infusiones Intravenosas/métodos , Estimación de Kaplan-Meier , Masculino , Método Simple Ciego , Taquicardia/terapia , Resultado del Tratamiento , Vena Cava Superior/embriología , Vena Cava Superior/inervación
6.
Heart Rhythm ; 15(9): 1321-1327, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29678784

RESUMEN

BACKGROUND: Esophageal thermal injury is a feared complication of radiofrequency ablation for atrial fibrillation (AF). Rise in luminal esophageal temperature (LET) limits the ability to deliver radiofrequency energy on the posterior wall of the left atrium. OBJECTIVE: The purpose of this study was to evaluate the feasibility, safety, and efficacy of a mechanical esophageal deviation (ED) tool during AF ablation. METHODS: We evaluated 687 patients who underwent radiofrequency ablation for AF. In 209 patients, the EsoSure (Northeast Scientific) was used to deflect the esophagus away from the ablation site. Propensity score matching was performed to obtain 180 patients each in the ED and non-ED arms. ED was used for LET rise seen in 61.7% of patients (111/180) and was used if the esophagus was in the line of ablation on fluoroscopy in 38.3% of patients (69/180). RESULTS: Mean deviation of trailing edge of esophagus with EsoSure was 2.45 ± 0.9 cm (range 1-4.5). LET rise >1°C was significantly lower in the ED than non-ED group (3% vs 79.4%; P <.001). Mean LET rise was also lower in the ED arm (ED 0.34 ± 0.59 vs non-ED 1.66 ± 0.54; P <.001). Intraprocedural success of pulmonary vein antral isolation, was slightly improved in the ED arm than in the non-ED arm without statistical significance. AF recurrence was lower in the ED arm at 3-month, 6-month, and 1-year follow-up than in the non-ED arm. No ED-related complications were noted. CONCLUSION: Mechanical displacement of the esophagus with EsoSure seems to be feasible, safe, and efficacious in enabling adequate radiofrequency energy delivery to the posterior wall of the left atrium without significant LET rise and obvious clinical signs of esophageal injury.


Asunto(s)
Aleaciones , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Esófago/fisiopatología , Atrios Cardíacos/cirugía , Monitoreo Intraoperatorio/métodos , Complicaciones Posoperatorias/prevención & control , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Temperatura Corporal , Ecocardiografía Transesofágica , Esófago/diagnóstico por imagen , Esófago/lesiones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
7.
Int J Cardiol ; 266: 187-192, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-29705650

RESUMEN

BACKGROUND: In a randomized trial, baroreflex activation therapy (BAT) improved exercise capacity, quality of life and NT-proBNP in patients with heart failure with reduced ejection fraction (HFrEF). In view of different mechanisms underlying HFrEF, we performed a post-hoc subgroup analysis of efficacy and safety of BAT in patients with and without coronary artery disease (CAD). METHODS AND RESULTS: Patients with left ventricular ejection fraction <35% and NYHA Class III were randomized 1:1 to guideline-directed medical and device therapy alone or plus BAT. Patients with a history of CAD, prior myocardial infarction or coronary artery bypass graft were assigned to the CAD group with all others assigned to the no-CAD group. Of 71 BAT treated patients, 52 had CAD and 19 had no CAD. In the control group, 49 of 69 patients had CAD and 20 had no CAD. The system- or procedure-related major adverse neurological or cardiovascular event rate was 3.8% in the CAD group vs. 0% in the no-CAD group (p = 1.0). In the whole cohort, NYHA Class, Minnesota Living with Heart Failure score, 6-minute hall walk distance and NTproBNP were improved in BAT treated patients compared with controls. Statistical analyses revealed no interaction between the presence of CAD and effect of BAT (all p > 0.05). CONCLUSION: No major differences were found in BAT efficacy or safety between patients with and without CAD, indicating that BAT improves exercise capacity, quality of life and NTproBNP in patients with ischemic and non-ischemic cardiomyopathy. CLINICALTRIALS. GOV IDENTIFIER: NCT01471860 and NCT01720160.


Asunto(s)
Barorreflejo/fisiología , Enfermedad de la Arteria Coronaria/terapia , Terapia por Estimulación Eléctrica/métodos , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología , Biomarcadores/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/fisiopatología , Terapia por Estimulación Eléctrica/instrumentación , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Estudios Retrospectivos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 40(12): 1432-1439, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28975641

RESUMEN

BACKGROUND: Silent cerebral lesions (SCLs) are a potential complication of left atrial radiofrequency ablation (RFA) procedures for paroxysmal atrial fibrillation (PAF). We aimed to compare the incidence of SCLs in patients treated with irrigated RFA multielectrode catheters (nMARQ® Catheter group) and irrigated focal RFA catheters (NAVISTAR® THERMOCOOL® Catheter; TC group) after PAF ablation from subpopulation neurological assessment (SNA) cohorts of the REVOLUTION and reMARQable studies. METHODS: Data from SNA cohorts in the prospective, nonrandomized REVOLUTION study (March 2011-September 2013) and the prospective, randomized, controlled reMARQable study (October 2013-November 2015) were included. The incidence of SCLs was assessed pre- and postablation using magnetic resonance imaging. Neurological deficits were assessed using the National Institutes of Health Stroke Scale, modified Rankin Scale, and Montreal Cognitive Assessment. RESULTS: A total of 37 patients from REVOLUTION and 76 patients from reMARQable were included in the SNA cohort of each study. In the REVOLUTION SNA cohort, the incidence of SCLs was 21.1% (4/19) in the nMARQ® Catheter group and 5.9% (1/17) in the TC group. Findings from REVOLUTION helped inform the reMARQable study protocol's stringent anticoagulation regimen. SCL incidence was subsequently reduced in both groups (nMARQ® Catheter, 7.9%; TC, 3.3%). No permanent neurological deficits were observed. CONCLUSION: Adherence to a stringent anticoagulation regimen prior to and during ablation procedures appears to be an important factor in minimizing the risk of SCL.


Asunto(s)
Anticoagulantes/efectos adversos , Enfermedades Asintomáticas , Encefalopatías/etiología , Encefalopatías/prevención & control , Ablación por Catéter/efectos adversos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Fibrilación Atrial/cirugía , Coagulación Sanguínea , Encefalopatías/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
JACC Clin Electrophysiol ; 3(4): 393-402, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28596994

RESUMEN

INTRODUCTION: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation. METHODS: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF. RESULTS: Sources were seen in all patients. More patients with de novo PAF (78.0%) had sources near PVs than patients with redo PAF (47.4%, p=0.005) or persistent AF (46.9%, p=0.001). The total number of sources per patient (p=0.444), and number of non-PV sources (p=0.701) were similar between groups, indicating that redo PAF patients had residual non-PV sources after elimination of PV sources by prior PVI. Structurally, left atrial size did not separate de novo from redo PAF (49.5±9.5 vs. 49.0±7.1mm, p=0.956) but was larger in patients with persistent AF (55.2±8.4mm, p=0.001). CONCLUSIONS: Patients with paroxysmal AF despite prior PVI show electrical substrates that resemble persistent AF more closely than patients with paroxysmal AF at first ablation. Notably, these subgroups of paroxysmal AF are indistinguishable by structural indices. These data motivate studies of trigger versus substrate mechanisms for patients with recurrent paroxysmal AF after PVI.


Asunto(s)
Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Recurrencia , Reoperación , Resultado del Tratamiento
10.
J Interv Card Electrophysiol ; 49(2): 197-204, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28413854

RESUMEN

BACKGROUND: Pocket hematoma is a recognized complication after placement of cardiac implantable electronic devices and is associated with increased device infection, length of hospitalization, and morbidity especially with uninterrupted antiplatelet agents and anticoagulants. We assessed the use of a post-surgical vest to decrease the incidence of pocket hematoma in patients undergoing device implantation with uninterrupted antiplatelet and anticoagulants. METHODS: In this observational study, a vest was used by 20 consecutive patients who were compared to 20 age-, gender-, procedure-matched patients who received standard care. All patients were continued on antiplatelet and anticoagulants in the perioperative period. The pocket was assessed at post procedure day 0, 2, and 7, respectively. RESULTS: There were no significant differences in the baseline characteristics between both groups. Baseline mean international normalized ratio (INR) was significantly higher in the vest group when compared with the control group (2.7 ± 0.4 vs. 2.2 ± 0.3 = <0.001). The incidence of pocket hematoma was significantly lower in the vest group than the control group (0 vs 30%, p = 0.02) at the end of 7 days. Control group had a total of six hematomas with one patient requiring evacuation and blood transfusion. The vest group had three hematomas on day 2 that resolved by day 7. CONCLUSIONS: The risk of moderate or large pocket hematoma is significantly reduced with the use of this vest in high-risk patients undergoing implantable devices on uninterrupted antiplatelet and anticoagulants.


Asunto(s)
Vendajes de Compresión , Desfibriladores Implantables/efectos adversos , Hematoma/etiología , Hematoma/prevención & control , Marcapaso Artificial/efectos adversos , Anticoagulantes/uso terapéutico , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA