Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
1.
Ophthalmol Glaucoma ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39004222

RESUMEN

PURPOSE: To compare safety, effectiveness and baseline predictors of failure in standalone primary Xen45 gel stent (Xen) vs trabeculectomy (Trab) in glaucoma. DESIGN: Retrospective study SUBJECTS: Subjects that underwent primary Xen or Trab augmented by mitomycin-C with at least 12 months follow-up. METHODS: Multinational observational study of eyes in the Fight Glaucoma Blindness international registry MAIN OUTCOME MEASURES: The primary outcome was success at 12 months defined by IOP reduction ≥ 20% from baseline and ≤ threshold IOPs of 15mmHg, 18mmHg and 21mmHg with (qualified) or without (complete) medications and without secondary glaucoma surgery. Multivariable mixed effects cox regression models were used to identify risk factors for failure in each cohort. RESULTS: 701 eyes (Xen, 308; Trab, 393) of 596 subjects were included with baseline IOP being significantly higher (22.4 vs 19.9 mmHg, p < 0.001) and baseline medications significantly lower in the Xen vs the Trab group (2.9 vs 3.4, p <0.001). Baseline visual field (VF) mean deviation (MD) was less severe in the Xen group (-9.47 vs -13.04 dB, p < 0.001). The proportion of complete surgical success was significantly lower in the Xen vs Trab group across the three upper IOP limits at 12 months; 32% vs 52% at 15mmHg, 37% vs 54% at 18mmHg, and 39% vs 55% at 21mmHg (p < 0.001). The incidence of post-operative numerical and symptomatic hypotony was lower in the Xen vs Trab group. In the Xen cohort, a higher failure rate was associated with Asian ethnicity (HR, 1.97; 95% CI, 1.03-3.79) and use of oral acetazolamide at baseline (HR, 1.74; 1.13-2.70), while a lower failure rate was associated with diagnosis of ocular hypertension/open angle glaucoma suspect (HR, 0.52; 0.28-0.94) and secondary open angle glaucoma (HR, 0.45; 0.25-0.8). Exposure to prostaglandin analogue was associated with greater failure in the Trab group (HR, 2.66; 1.18-6.01). CONCLUSIONS: There was significantly greater complete success at 12 months across all complete success definitions for Trab compared to Xen, while the rate of post-operative hypotony was significantly lower in Xen group. Asian ethnicity and use of oral acetazolamide at baseline were associated with greater failure in Xen, while exposure to prostaglandin analogue was associated with greater failure in Trab patients. Such baseline predictors of success and failure may help guide patient selection for subconjunctival minimally invasive glaucoma surgery in patients undergoing surgical intervention.

2.
Commun Med (Lond) ; 4(1): 132, 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38971929

RESUMEN

BACKGROUND: The widespread use of physical activity trackers enables the collection of high-resolution health data, such as hourly step counts, to evaluate health promotion programmes. We aim to investigate how participants meet their daily step goals. METHODS: We used 24-h steps data from the National Steps ChallengeTM Season 3, wherein participants were rewarded with vouchers when achieving specified goals of 5000, 7500, and 10,000 steps per day. We extracted data from 3075 participants' including a total of 52,346 participant-days. We modelled the hourly step counts using a two-part model, in which the distribution for step counts was allowed to depend on the sum of step counts up to the previous hour and participant demographics. RESULTS: Participants have a mean age of 44.2 years (standard deviation = 13.9), and 40.4% are males. We show that on weekdays, the hourly mean step counts among participants aged 60 and above are higher than participants aged 30 to 59 from the start of the day till 6 p.m. We also find that participants who accumulate at least 7000 steps by 7 p.m. are associated with higher success of achieving 10,000 steps. CONCLUSIONS: We provide recommendations on the hourly targets to achieve daily goals, based on different participants' characteristics. Future studies could experimentally test if prompts and nudges at the recommended times of day could promote reaching step goals.


The National Steps ChallengeTM is a nationwide physical activity programme in Singapore that encourages participants to exercise more. We used daily step data from over 3000 adult participants to investigate how different types of participants met their daily step goals. We found that participants who had taken at least 7000 steps by 7 p.m. were more likely to achieve 10,000 steps by the end of the day. Based on our analysis, we propose specific recommendations for hourly targets based on characteristics such as age and sex. Our study provides a better understanding of the population's physical activity levels which will enable people to be given targeted recommendations based on their own characteristics that might facilitate them more easily meeting their exercise goals.

3.
Obes Surg ; 34(7): 2363-2368, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38748346

RESUMEN

PURPOSE: Obesity, defined as abnormal or excessive fat accumulation that presents a risk to health, rose from 8.6 to 10.5% in Singapore's residents. Bariatric surgery, the primary treatment for severe obesity, induces fat and muscle loss. Adequate protein intake is vital for preventing muscle loss. This study examines nitrogen balance in individuals with obesity pre- and post-surgery. MATERIALS AND METHODS: Sixteen participants with severe obesity (BMI ≥ 32.5 kg/m2) undergoing bariatric surgery (14 sleeve gastrectomy, 2 Roux-en-Y gastric bypass) and 20 normal-weight controls (BMI < 25 kg/m2) were recruited. Nitrogen balance, calculated from dietary protein intake and urine nitrogen excretion, was assessed. Participants with obesity were re-evaluated 6 months post-surgery. Data were analyzed using parametric methods. RESULTS: At baseline, controls had a BMI of 20.8 ± 2.1 kg/m2; those with obesity had 40.9 ± 7.3. Daily calorie and protein intake for participants with obesity were not statistically significantly different from controls (calorie intake at 1467 ± 430 vs. 1462 ± 391 kcal, p = 0.9701, protein intake 74.2 ± 28.7 vs. 64.6 ± 18.3 g, p = 0.2289). Post-surgery, BMI, fat-free mass, fat mass, total energy intake, carbohydrate, and protein intake decreased significantly (p < 0.01). Protein oxidation and urine nitrogen excretion did not change after bariatric surgery. However, nitrogen balance significantly reduced from 2.62 ± 5.07 to - 1.69 ± 5.07 g/day (p = 0.025). CONCLUSION: Dietary protein intake is inadequate in individuals with obesity at 6 months post-bariatric surgery and contributes to a state of negative nitrogen balance.


Asunto(s)
Nitrógeno , Obesidad Mórbida , Pérdida de Peso , Humanos , Femenino , Nitrógeno/metabolismo , Nitrógeno/orina , Masculino , Obesidad Mórbida/cirugía , Obesidad Mórbida/metabolismo , Adulto , Pérdida de Peso/fisiología , Singapur , Persona de Mediana Edad , Cirugía Bariátrica , Proteínas en la Dieta/administración & dosificación , Índice de Masa Corporal , Gastrectomía , Ingestión de Energía , Periodo Posoperatorio
4.
Sci Adv ; 10(14): eadk9754, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38578994

RESUMEN

The lack of bacterial-targeting function in antibiotics and their prophylactic usage have caused overuse of antibiotics, which lead to antibiotic resistance and inevitable long-term toxicity. To overcome these issues, we develop neutrophil-bacterial hybrid cell membrane vesicle (HMV)-coated biofunctional lipid nanoparticles (LNP@HMVs), which are designed to transport antibiotics specifically to bacterial cells at the infection site for the effective treatment and prophylaxis of bacterial infection. The dual targeting ability of HMVs to inflammatory vascular endothelial cells and homologous Gram-negative bacterial cells results in targeted accumulation of LNP@HMVs in the site of infections. LNP@HMVs loaded with the antibiotic norfloxacin not only exhibit enhanced activity against planktonic bacteria and bacterial biofilms in vitro but also achieve potent therapeutic efficacy in treating both systemic infection and lung infection. Furthermore, LNP@HMVs trigger the activation of specific humoral and cellular immunity to prevent bacterial infection. Together, LNP@HMVs provide a promising strategy to effectively treat and prevent bacterial infection.


Asunto(s)
Infecciones Bacterianas , Nanopartículas , Humanos , Células Endoteliales , Infecciones Bacterianas/tratamiento farmacológico , Infecciones Bacterianas/prevención & control , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Liposomas
5.
Surg Obes Relat Dis ; 20(6): 532-543, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38302307

RESUMEN

BACKGROUND: Laparoscopic sleeve gastrectomy (SG) is a widely performed bariatric surgery, but it is associated with an increased risk of gastroesophageal reflux (GERD) in the long term. The addition of fundoplication to laparoscopic SG may improve lower oesophageal sphincter function and reduce postoperative GERD. OBJECTIVES: This systematic review and meta-analysis aims to compare the efficacy and safety of SG plus fundoplication (SG + F) versus SG alone for the treatment of patients with severe obesity (≥35 kg/m2). SETTING: Meta-analysis. METHODS: Three electronic databases were searched from inception until January 2023. Studies were included if they compared outcomes of SG + F versus SG in patients with severe obesity (≥35 kg/m2). The primary outcome was remission of GERD postoperatively. Secondary outcomes were the percentage of excess weight loss, percentage of total weight loss, postoperative complication rate, operative time, and length of stay. RESULTS: A total of 5 studies with 539 subjects (212 SG + F and 327 SG alone) were included. The mean preoperative body mass index was 42.6 kg/m2. SG + F achieved higher remission of GERD compared with laparoscopic SG (odds ratio [OR] = 13.13; 95% CI, 3.54-48.73; I2 = 0%). However, the percentage of total weight loss was lower in the SG + F group (mean difference [MD] = -2.75, 95% CI, -4.28 to -1.23; I2 = 0%), whereas there was no difference in the percentage of excess weight loss (MD = -0.64; 95% CI, -20.62-19.34; I2 = 83%). There were higher postoperative complications in SG + F (OR = 2.56; 95% CI, 1.12-5.87; I2 = 0%) as well. There was no difference in operative time or length of stay between the 2 groups. CONCLUSION: SG + F achieved better GERD remission but is associated with lesser weight loss and increased postoperative complications compared with SG alone. Further studies are required to ascertain the overall clinical benefit of SG + F for patients with severe obesity.


Asunto(s)
Fundoplicación , Gastrectomía , Reflujo Gastroesofágico , Obesidad Mórbida , Humanos , Obesidad Mórbida/cirugía , Obesidad Mórbida/complicaciones , Gastrectomía/métodos , Fundoplicación/métodos , Reflujo Gastroesofágico/cirugía , Reflujo Gastroesofágico/etiología , Laparoscopía/métodos , Pérdida de Peso , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Cirugía Bariátrica/métodos , Cirugía Bariátrica/efectos adversos , Femenino , Adulto , Masculino
6.
Eur Surg Res ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38412840

RESUMEN

INTRODUCTION: Laparoscopic sleeve gastrectomy (LSG) is associated with postoperative gastroesophageal reflux disease (GERD) and erosive esophagitis (EE). The role of crural repair during LSG is still controversial. The preoperative laxity of the gastroesophageal junction (GEJ), graded by the Hill's classification, is more predictive for postoperative GERD and EE after LSG than the presence of a hiatal hernia seen on endoscopy. Thus, the authors hypothesize that a concomitant crural repair in a specific subgroup of patients with a lax GEJ (Hill's III) may reduce the incidence of postoperative GERD and EE. METHODS: A double-blinded, randomized controlled trial of patients with Hill's III GEJ undergoing LSG will be randomized to a concomitant crural repair (experimental) versus LSG alone (control). Primary outcome measures will be presence of EE at 1-year. Secondary outcome measures will include proton pump inhibitor use, postoperative complications, operative time, blood loss, quality of life, GERD and gastrointestinal symptoms. CONCLUSION: Conflicting crural repair results may be explained by differences in preoperative GEJ laxity. Patients with a frank hiatal hernia and patulous GEJ (Hill's IV) have a very high, while patients with an apposed GEJ (Hill's I, Hill's II) have a low incidence of postoperative GERD and EE respectively. Thus, the authors hypothesize that patients with a lax GEJ without frank hiatal hernia (Hill's III), might benefit from a crural repair. This study results can potentially highlight the clinical importance of preoperative endoscopic evaluation of the GEJ in all patients planned for LSG, to determine which subgroup patients may benefit from a crural repair. (Clinicaltrials.gov: NCT05330910, Registered 15-April-2022).

7.
Ophthalmic Plast Reconstr Surg ; 40(3): e78-e80, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38231618

RESUMEN

Orbital reconstruction following orbital trauma, tissue sacrifice from cancer resection, or other tissue loss poses a unique challenge for surgeons. Factors to consider include the patient's systemic health status, potential for adjuvant radiation, final composition, and strength of the graft, infection risk, graft rejection, status of visual function, and cosmetic outcome. In settings where a permanent artificial implant is avoided due to exposure or infection risk, potential tissue utilized includes xenografts, allografts, and autografts-each with variable benefits and drawbacks, depending on the surgical goals of the repair. We describe a case of orbital reconstruction after a gunshot wound to the left orbit using tri-layer Kerecis (decellularized intact North-Atlantic cod fish skin) with excellent globe position and maintenance of ocular motility.


Asunto(s)
Órbita , Procedimientos de Cirugía Plástica , Humanos , Animales , Procedimientos de Cirugía Plástica/métodos , Masculino , Órbita/lesiones , Heridas por Arma de Fuego/cirugía , Trasplante de Piel/métodos , Peces , Procedimientos Quirúrgicos Oftalmológicos/métodos , Lesiones Oculares Penetrantes/cirugía , Lesiones Oculares Penetrantes/diagnóstico , Adulto , Fracturas Orbitales/cirugía , Fracturas Orbitales/diagnóstico
8.
Ophthalmic Physiol Opt ; 44(2): 426-441, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38226742

RESUMEN

PURPOSE: To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. METHODS: A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10-year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA-Faster variability characteristics from previous work. Additional variables included follow-up intervals (six-monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. RESULTS: When the Swedish cohort was reviewed six-monthly, the frontloaded strategy detected more progressors compared to the non-frontloaded method up to years 8, 9 and 10 of follow-up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0-1.5 years less for frontloading compared to non-frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non-frontloaded strategy (78.5%-81.5% and by 1.0-1.3 years when reviewed six-monthly; 81%-82.9% and by 1.2-2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six-monthly review: 0.63-1.67 dB 'saved'; yearly review: 1.10-2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. CONCLUSIONS: Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.


Asunto(s)
Glaucoma , Pruebas del Campo Visual , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales , Presión Intraocular , Simulación por Computador , Estudios de Seguimiento , Estudios Retrospectivos , Trastornos de la Visión/diagnóstico , Progresión de la Enfermedad , Canadá , Glaucoma/diagnóstico
9.
J Virol Methods ; 324: 114860, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38061674

RESUMEN

Hepatitis E virus (HEV) generally causes acute liver infection in humans and its transmission could be waterborne, foodborne, bloodborne, or zoonotic. To date, there is no standard method for the detection of HEV from food and environmental samples. Herein, we explored the possibility of using magnetic beads for the capture and detection of HEV. For this purpose, we employed Dynabeads M-270 Epoxy magnetic beads, coated with different monoclonal antibodies (mAbs) against HEV capsid protein, and the Nanotrap Microbiome A Particle magnetic beads, which are coated with chemical affinity baits, to capture HEV-3 particles in suspension. Viral RNA was extracted by heat-shock or QIAamp viral RNA kit and subjected to quantification using digital-droplet RT-PCR (ddRT-PCR). We demonstrated that the mAb-coupled Dynabeads and the Nanotrap particles, both were able to successfully capture HEV-3. The latter, however had lower limit of detection (<140gc compared with <1400 gc) and significantly higher extraction efficiency in comparison to the mAb-coupled Dynabeads (41.1% vs 8.8%). We have also observed that viral RNA extraction by heat-shock is less efficient compared to using highly denaturing reagents in QIAmp viral RNA extraction kit. As such, magnetic beads have the potential to be used to capture HEV virions for research and surveillance purposes.


Asunto(s)
Virus de la Hepatitis E , Hepatitis E , Humanos , Virus de la Hepatitis E/genética , Hepatitis E/epidemiología , Proteínas de la Cápside/genética , Anticuerpos Monoclonales , ARN Viral/genética , ARN Viral/análisis
10.
Ophthalmology ; 131(6): 658-666, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38110124

RESUMEN

PURPOSE: The newly released Swedish Interactive Thresholding Algorithm (SITA)-Faster (SFR) has significantly shorter testing durations compared with older SITA algorithms, but its variability is uncertain. This study quantified and established threshold limits of test-retest variability across the 24-2 test grid using SFR. DESIGN: Cross-sectional study with prospective longitudinal arm. PARTICIPANTS: 1426 eyes of 787 patients with healthy, suspected glaucoma, or manifest glaucoma eyes from hospital- and university- eye clinics. METHODS: Two SFR tests per eye at a baseline visit and at two follow-up visits. MAIN OUTCOME MEASURES: Pointwise variability measured by test-retest difference in pointwise sensitivity between tests one and two, mean global variability (test-retest variance) measured by average of pointwise variability for each participant, global sensitivity, and reliability indices of each eye. RESULTS: Of the 1426 eyes, 540 eyes (37.9%) had a diagnosis of glaucoma, 753 eyes (52.8%) were suspected of having glaucoma, and the remaining 133 eyes (9.3%) were healthy. Of 74 152 pointwise sensitivities obtained, the mean test-retest difference was 2.17 ± 2.9 dB, whereas the mean test-retest variance for each participant was 2.17 ± 1.2 dB. Pointwise and global variability increased with worsening threshold sensitivity and (MD), respectively, and was greater for peripheral compared with central test locations. In the longitudinal cohort, no significant difference in mean test-retest variance was found across the 3 visits (mean variability, 2.10 dB vs. 2.16 dB vs. 2.16 dB at visits F0 vs. F1 vs. F2; P = 0.53, repeated-measures analysis of variance). Baseline MD (-0.19 dB; 95% CI, -0.22 to 0.16 dB; P < 0.0001) and abnormally high sensitivity on glaucoma hemifield test (1.14 dB; 95% CI, 0.78-1.51 dB; P < 0.0001) were significantly associated with increased variability. Finally, test-retest MD showed minimal change around the recommended 15% false-positive cutoff threshold. CONCLUSIONS: The variability of SFR increases with worsening threshold sensitivity, is stable over time, and is greater for peripheral compared with central test locations. Worse baseline MD and abnormally high sensitivity are significant predictors of increased variability. A cutoff of 15% in false-positive results may be inappropriate as a threshold for judging test reliability in SFR. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Algoritmos , Presión Intraocular , Hipertensión Ocular , Pruebas del Campo Visual , Campos Visuales , Humanos , Campos Visuales/fisiología , Masculino , Estudios Prospectivos , Femenino , Estudios Transversales , Pruebas del Campo Visual/métodos , Persona de Mediana Edad , Presión Intraocular/fisiología , Anciano , Reproducibilidad de los Resultados , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/fisiopatología , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Sensibilidad y Especificidad , Adulto , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/fisiopatología , Umbral Sensorial/fisiología
11.
Bioengineering (Basel) ; 10(10)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37892916

RESUMEN

This paper describes a technique for using swept-source anterior segment optical coherence tomography (AS-OCT) to visualize internal bleb microstructure and objectively quantify dimensions of the scleral flap and trabeculo-Descemet window (TDW) in non-penetrating glaucoma filtration surgery (GFS). This was a cross-sectional study of 107 filtering blebs of 67 patients who had undergone deep sclerectomy surgery at least 12 months prior. The mean post-operative follow-up duration was 6.5 years +/- 4.1 [standard deviation (SD)]. The maximal bleb height was significantly greater in the complete success (CS) blebs compared to the qualified success (QS) and failed (F) blebs (1.48 vs. 1.17 vs. 1.10 mm in CS vs. QS vs. F, one-way ANOVA, p < 0.0001). In a subcohort of deep sclerectomy blebs augmented by intraoperative Mitomycin-C, the trabeculo-Descemet window was significantly longer in the complete success compared to the qualified success group (613.7 vs. 378.1 vs. 450.8 µm in CS vs. QS vs. F, p = 0.004). The scleral flap length, thickness, and width were otherwise similar across the three outcome groups. The quantification of surgical parameters that influence aqueous outflow in non-penetrating GFS can help surgeons better understand the influence of these structures on aqueous outflow and improve surgical outcomes.

12.
Surg Endosc ; 37(11): 8349-8356, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37700012

RESUMEN

OBJECTIVE: We aim to evaluate the cost-saving of the short stay ward (SSW) versus conventional inpatient care following sleeve gastrectomy (LSG). We also compared the readmission rates pre- and post-inception of the intravenous hydration clinic and analyzed the cost-savings. METHODS: Patients who underwent LSG between December 2021 to March 2022 with SSW care were compared with standard inpatient care. Total costs were analyzed using univariate analysis. With a separate cohort of patients, 30-day readmission rates in the 12-months preceding and following implementation of the IV hydration clinic and associated cost-savings were evaluated. RESULTS: After matching on the propensity score to within ± 0.1, 20-subjects pairs were retained. The total cost per SSW-subject was significantly lower at $13,647.81 compared to $15,565.27 for conventional inpatient care (p = 0.0302). Lower average ward charges ($667.76 vs $1371.34, p < 0.0001), lower average daily treatment fee per case ($235.68 vs $836.54, p < 0.0001), and lower average laboratory investigation fee ($612.31 vs $797.21, p < 0.0001) accounted for the difference in costs between the groups. Thirty-day readmission rate reduced from 8.9 to 1.8% after implementation of the hydration clinic (p < 0.01) with decreased 30-day readmission cost (S$96,955.57 vs. S$5910.27, p < 0.01). CONCLUSION: SSW for LSG is cost-effective and should be preferred to inpatient management. Walk-in hydration clinics significantly reduced readmission rates and result in tremendous cost-savings.


Asunto(s)
Laparoscopía , Obesidad Mórbida , Humanos , Tiempo de Internación , Pacientes Internos , Hospitalización , Readmisión del Paciente , Gastrectomía , Complicaciones Posoperatorias , Estudios Retrospectivos , Obesidad Mórbida/cirugía , Resultado del Tratamiento
13.
Prenat Diagn ; 2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37776084

RESUMEN

BACKGROUND: Artificial intelligence (AI) has the potential to improve prenatal detection of congenital heart disease. We analysed the performance of the current national screening programme in detecting hypoplastic left heart syndrome (HLHS) to compare with our own AI model. METHODS: Current screening programme performance was calculated from local and national sources. AI models were trained using four-chamber ultrasound views of the fetal heart, using a ResNet classifier. RESULTS: Estimated current fetal screening programme sensitivity and specificity for HLHS were 94.3% and 99.985%, respectively. Depending on calibration, AI models to detect HLHS were either highly sensitive (sensitivity 100%, specificity 94.0%) or highly specific (sensitivity 93.3%, specificity 100%). Our analysis suggests that our highly sensitive model would generate 45,134 screen positive results for a gain of 14 additional HLHS cases. Our highly specific model would be associated with two fewer detected HLHS cases, and 118 fewer false positives. CONCLUSION: If used independently, our AI model performance is slightly worse than the performance level of the current screening programme in detecting HLHS, and this performance is likely to deteriorate further when used prospectively. This demonstrates that collaboration between humans and AI will be key for effective future clinical use.

14.
Can J Ophthalmol ; 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37652089

RESUMEN

OBJECTIVE: To determine the effect of frontloading (multiple) visual field (VF) tests at the same visit for detecting mean deviation (MD) change in slowly progressive glaucoma. METHODS: This was a computer simulation study. Baseline MD (range, 0 to -12 dB) and progression rate (range, 0 to -0.4 dB/year, non-inclusive) were generated for 10,000 patients. Each patient had 6 simulated "stable" baseline VF tests. Then follow-up VFs (up to 10 years) were generated by incorporating progression rate and within-visit and between-visit variability. The independent variables were number of VF tests per visit (one non-frontloaded or two frontloaded), VF reliability (100%, 85%, or 70%), repeat testing because of unreliable results (yes or no), and follow-up interval (6-monthly or yearly). The outcomes were detection of progression (MD slope that was negative and significant at p < 0.05), MD at detection, and number of years to detection. RESULTS: Frontloading identified more progressors (62.7%-79.2%) compared with non-frontloading (31.0%-36.7%) at 10 years (p < 0.0001). Six-monthly follow-ups led to greater detection than yearly intervals. Progressors detected by both methods were detected by the non-frontloaded method sooner (up to 0.26 years), but this was small and not clinically significant (MD difference, 0.06 dB). An increase (less severe) in MD, an increase (slower) in progression rate, and an increase in SD of baseline VFs decreased the likelihood of detecting progression. CONCLUSIONS: Frontloading VF tests at 6-monthly intervals improve detection rates of MD progression in slowly progressive glaucoma patients compared with performing 1 test per visit at yearly intervals.

16.
Asian J Endosc Surg ; 16(4): 731-740, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37524315

RESUMEN

INTRODUCTION: Completion gastrectomy with lymphadenectomy for remnant gastric cancer (RGC) is currently the gold standard for patients with resectable disease. Multiple surgical approaches can be adopted; however, there exists no agreement on the best choice due to the low incidence of RGC. With its anticipated increase in prevalence, we thus sought to evaluate the feasibility and efficacy of the laparoscopic approach versus conventional laparotomy via a pooled analysis of existing literature. METHODS: A retrospective review of five consecutive patients who underwent laparoscopic completion gastrectomy from August 2017 to June 2022 was performed following Institutional Review Board waiver. A comprehensive systematic review of literature on laparoscopic completion gastrectomy from the Pubmed, Embase, MEDLINE, Web of Science and Cochrane databases was conducted to supplement the experience from our institution. RESULTS: Four patients had prior benign gastric disease and one had prior gastric cancer. Two patients experienced severe postoperative complications but there were otherwise no reports of conversion to laparotomy or mortality. Mean operative duration was 295 minutes. Mean duration to oral intake and discharge was 6.8 and 14.6 days respectively. Results from our pooled analysis of 591 cases suggested that the laparoscopic approach was associated with longer operative durations but delivered fewer postoperative complications, shorter duration to dietary resumption and shorter lengths of stay over conventional laparotomy. CONCLUSION: Laparoscopic completion gastrectomy is indeed a more challenging procedure due to the presence of dense adhesions from previous surgery. However, the procedure can be performed safely with superior outcomes as compared to conventional laparotomy.


Asunto(s)
Laparoscopía , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/complicaciones , Gastrectomía/métodos , Escisión del Ganglio Linfático/efectos adversos , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Laparoscopía/métodos , Resultado del Tratamiento
17.
Ophthalmology ; 130(11): 1138-1148, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37385298

RESUMEN

PURPOSE: Frontloading SITA-Faster (SFR) visual fields (2 tests per eye on the same visit) has been shown to provide repeatable perimetric data at minimal time cost. This study reports the outcomes of using frontloaded SFR in the evaluation of pointwise visual field (VF) defects in a cohort of patients with glaucoma when transitioned from SITA-Standard (SS). DESIGN: Prospective, cross-sectional study. PARTICIPANTS: A total of 144 eyes of 91 patients with confirmed or suspected glaucoma who had an SS test on a previous visit. METHODS: Two SFR tests (T1, T2) per eye on the same visit. MAIN OUTCOME MEASURES: Global sensitivity, reliability indices, and pointwise deviation map probability scores from the pattern deviation grid of each patient were compared across the 3 sequential tests to evaluate the consistency of VF defects. RESULTS: The mean age was 68.6 years, and 79.2% of patients had a diagnosis of glaucoma. There was no significant difference in mean deviation (MD) across the 3 tests (-5.83 decibels [dB], -5.28 dB, and -5.71 dB in SS, SFR1, and SFR2, respectively, repeated-measures analysis of variance [ANOVA], P = 0.48). The frontloaded SFR tests provided repeatable VFs that confirmed existing pointwise data on the SS in 4661 (62.3%) locations, reversed an SS defect in 614 (8.2%) locations, and demonstrated a new repeatable defect in 406 (5.4%) locations of the pattern deviation grid. A new defect of at least 3 contiguous points was identified in 20.1% of eyes. The non-repeatable points on the 2 SFR tests displayed no significant difference in the distribution of defect/nondefect points based on test order or peripheral versus central locations. There was no significant difference in the rate of obtaining at least 1 reliable test result between SS and the frontloaded SFR T1 and T2 (P = 0.77). Test duration significantly decreased from SS to SFR1/2 (379 vs. 160 vs. 158 seconds, P < 0.0001). CONCLUSIONS: Frontloading SFR tests can provide repeatable data for the evaluation of the consistency of pattern deviation defects in glaucoma, with no observable decline in performance from test fatigue. This is achieved at equivalent duration and reliability as a single SS test. Frontloading SFR may be helpful in increasing testing frequency/quantity to meet recommended guidelines for progression analysis. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

18.
Int Ophthalmol ; 43(8): 2925-2933, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37029211

RESUMEN

PURPOSE: In recent years, methicillin-resistant Staphylococcus aureus (MRSA) orbital cellulitis (OC) has drawn increasing clinical and public health concern. We present a case series of MRSA OC encountered at four Australian tertiary institutions. METHODS: A multi-centre retrospective case series investigating MRSA OC in Australia from 2013 to 2022. Patients of all ages were included. RESULTS: Nine cases of culture-positive non-multi-resistant MRSA (nmMRSA) OC were identified at four tertiary institutions across Australia (7 male, 2 female). Mean age was 17.1 ± 16.7 years (range 13-days to 53-years), of which one was 13 days old, and all were immunocompetent. Eight (88.9%) patients had paranasal sinus disease, and seven (77.8%) had a subperiosteal abscess. Four (44.4%) had intracranial extension, including one (11.1%) case which was also complicated by superior sagittal sinus thrombosis. Empirical antibiotics, such as intravenous (IV) cefotaxime alone or IV ceftriaxone and flucloxacillin, were commenced. Following identification of nmMRSA, targeted therapy consisting of vancomycin and/or clindamycin was added. Nine (100%) patients underwent surgical intervention. Average hospital admission was 13.7 ± 6.9 days (range 3-25 days), with two patients requiring intensive care unit (ICU) admission due to complications related to their orbital infection. All patients had favourable prognosis, with preserved visual acuity and extraocular movements, following an average follow-up period of 4.6 months (range 2-9 months). CONCLUSION: NMMRSA OC can follow an aggressive clinical course causing severe orbital and intracranial complications across a wide demographic. However, early recognition, initiation of targeted antibiotics and surgical intervention when required can effectively manage these complications and achieve favourable visual outcomes.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Celulitis Orbitaria , Infecciones Estafilocócicas , Humanos , Masculino , Femenino , Recién Nacido , Celulitis Orbitaria/diagnóstico , Celulitis Orbitaria/tratamiento farmacológico , Estudios Retrospectivos , Australia/epidemiología , Antibacterianos/uso terapéutico , Infecciones Estafilocócicas/complicaciones , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/tratamiento farmacológico
19.
Surg Endosc ; 37(8): 5816-5824, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37055666

RESUMEN

BACKGROUND: Laparoscopic sleeve gastrectomy (LSG) has become the preferred bariatric procedure in many countries. However, new onset erosive esophagitis (EE) is a major shortcoming. Current recommendation is esophago-gastro-duodenoscopy (EGD) should be performed routinely at 1 year and subsequently every 2-3 years to enable the early detection of Barrett's or esophageal adenocarcinoma. This would put significant strains on resources and costs of bariatric program. Our study assesses the association between and diagnostic value of salivary pepsin concentration and endoscopically proven EE in post-LSG patients as a surrogate for EGD. METHODS: Twenty patients on routine post-LSG endoscopy between June and September 2022 were recruited for this correlational pilot study. Under supervision, fasting and post-prandial saliva sample was collected and analyzed by Peptest lateral flow device. EGD examinations were performed, and patients completed a validated 25-item QoLRAD questionnaire. RESULTS: We found a significant correlation between positive endoscopy findings of EE and salivary pepsin concentrations. The normal group had a lower mean fasting pepsin level (13.13 ng/mL ± 18.97) versus the EE-group (90.55 ng/mL ± 81.28, p = 0.009) and lower mean post-prandial pepsin level (30.50 ng/mL ± 57.72) versus the EE-group (135.09 ng/mL ± 130.17, p = 0.02). The predictive probabilities from the binary regression of fasting and post-prandial pepsin concentrations yield AUC of 0.955 ± 0.044 (95% CI 0.868 to 1.000, p < 0.001). CONCLUSION: Our study distinctively identified salivary pepsin to have excellent sensitivity and negative predictive value in EE, potentially useful to preclude the need for post-LSG EGD in asymptomatic patients with low salivary pepsin.


Asunto(s)
Esofagitis , Reflujo Gastroesofágico , Laparoscopía , Obesidad Mórbida , Úlcera Péptica , Humanos , Reflujo Gastroesofágico/cirugía , Pepsina A , Saliva , Proyectos Piloto , Esofagitis/diagnóstico , Esofagitis/etiología , Esofagitis/cirugía , Úlcera Péptica/cirugía , Gastrectomía/efectos adversos , Gastrectomía/métodos , Endoscopía Gastrointestinal , Obesidad Mórbida/cirugía , Laparoscopía/métodos
20.
Adv Healthc Mater ; 12(19): e2201560, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37071479

RESUMEN

Anticancer drug resistance is a large contributing factor to the global mortality rate of cancer patients. Anticancer macromolecules such as polymers have been recently reported to overcome this issue. Anticancer macromolecules have unselective toxicity because they are highly positively charged. Herein, an anionic biodegradable polycarbonate carrier is synthesized and utilized to form nanocomplexes with an anticancer polycarbonate via self-assembly to neutralize its positive charges. Biotin is conjugated to the anionic carrier and serves as cancer cell-targeting moiety. The nanoparticles have sizes of < 130 nm with anticancer polymer loading levels of 38-49%. Unlike the small molecular anticancer drug doxorubicin, the nanocomplexes effectively inhibit the growth of both drug-susceptible MCF7 and drug-resistant MCF7/ADR human breast cancer cell lines with low half maximal inhibitory concentration (IC50 ). The nanocomplexes increase the anticancer polymer's in vivo half-life from 1 to 6-8 h, and rapidly kill BT474 human breast cancer cells primarily via an apoptotic mechanism. The nanocomplexes significantly increase the median lethal dose (LD50 ) and reduce the injection site toxicity of the anticancer polymer. They suppress tumor growth by 32-56% without causing any damage to the liver and kidneys. These nanocomplexes may potentially be used for cancer treatment to overcome drug resistance.


Asunto(s)
Antineoplásicos , Neoplasias de la Mama , Nanopartículas , Humanos , Femenino , Semivida , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Doxorrubicina/farmacología , Nanopartículas/toxicidad , Polímeros , Neoplasias de la Mama/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...