Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
2.
G Ital Cardiol (Rome) ; 25(2): 106-111, 2024 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-38270366

RESUMEN

BACKGROUND: The extent of residual mitral regurgitation (MR) (1+ vs ≥2+) has a notable impact on the outcome of MitraClip (MC) repair of significant functional MR. In this retrospective single-center study, we evaluated the predictors of MI ≥2+ at 1 year in one of our case series. METHODS: Overall, 58 patients with moderate severe functional MR underwent MC implantation; of these, 48 patients had instrumental clinical follow-up for 1 year. RESULTS: At 1 year, 10 patients died (mortality 17.2%). In the remaining 48 patients, the incidence of rehospitalization was 8.3%, and the incidence of MR grade 1+ and ≥2+ was 54.1% (n = 26) and 45.9% (n = 22), respectively. In patients with MR ≥2+, clinical and instrumental outcomes were worse than in patients with MR 1+. The height of the posterior leaflet and the extent of immediate postprocedural MR were independent predictors of MR ≥2+. CONCLUSIONS: Percutaneous repair with MC of moderate/severe functional MR has favorable 1-year outcomes in terms of mortality and rehospitalizations. The best results are achieved in patients with residual MR 1+. Echocardiographic parameters are independent predictors of residual MR ≥2+.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Ecocardiografía , Readmisión del Paciente
3.
Catheter Cardiovasc Interv ; 88(7): 1177-1180, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26880720

RESUMEN

A 65-year-old woman was admitted to our institution for rest dyspnea and hypotension. EKG showed sinus tachycardia with signs of infero-posterior STEMI. 2D-echocardiogram showed severe left ventricular systolic dysfunction with a- diskynesia of the inferior and posterior walls and severe functional mitral regurgitation (MR). The patient underwent urgent coronary angiography that showed 3-vessels disease with total occlusion of both first obtuse marginal (OM) branch of the left circumflex artery and right coronary artery (RCA) and critical stenosis of left anterior descending (LAD). Because of extremely high surgical risk, we performed a staged totally percoutaneous approach. First, we reopened the presumed culprit vessels (RCA and OM) and then, after 48 hr, we performed angioplasty of the LAD. Since revascularization provided no significant improvement in respiratory and hemodynamic parameters we performed a percutaneous mitral repair with Mitraclip. MR grade was reduced from severe to trivial with rapid improvement of the respiratory and hemodynamic parameters. The post-procedural course was uneventful and the patient was discharged 7 days later. At the 30-day and 6-month follow-up the patient remained asymptomatic in NYHA I functional class with no recurrence of MR. Acute MR due to post-AMI mechanical complications is generally considered a contraindication to MitraClip implantation for several reasons. However, the present report shows that, in selected cases, the Mitraclip system may be successfully used to reduce the severity of acute MR secondary to AMI and may allow to reverse cardiogenic shock and/or refractory pulmonary congestion related to the acute regurgitation. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón , Cateterismo Cardíaco/instrumentación , Oclusión Coronaria/terapia , Estenosis Coronaria/terapia , Insuficiencia de la Válvula Mitral/terapia , Infarto del Miocardio con Elevación del ST/etiología , Anciano , Angioplastia Coronaria con Balón/instrumentación , Angiografía Coronaria , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/fisiopatología , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Stents Liberadores de Fármacos , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Hemodinámica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Recuperación de la Función , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
4.
Cardiovasc Ultrasound ; 13: 49, 2015 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-26714887

RESUMEN

BACKGROUND: Previous studies have suggested that concomitant mitral regurgitation (MR) is a risk factor for acute transcatheter aortic valve implantation (TAVI) failure, but may improve afterwards. Aim of this study was to assess the prevalence, clinical meaning and modifications of MR in patients undergoing TAVI. METHODS: In a retrospective, two-center (Potenza-San Carlo and Roma- San Camillo) study, from January 2010 to June 2014 we enrolled 165 consecutive patients (age =80 ± 5 years, 74 males, Ejection Fraction 51 ± 9 %) referred for TAVI with either Medtronic Core-ReValving System (in 114 patients, 69%) or balloon-expandable Edwards SAPIEN/SAPIEN XT (in 51 patients, 31%). All patients underwent TTE and TEE assessment of MR (from 1, mild to 4 = severe according to ESC latest guidelines) with core lab reading by a single observer blinded to patient identity and status. Assessment was performed at baseline (24 h prior to intervention) and at 1, 6, 12 and 24 months. RESULTS: Mild-to-Moderate MR (grade 1-2) was present in 137 patients and Moderate-to-Severe MR (grade 3-4) was present in 28 patients. No significant differences were seen comparing perioperative mortality and morbidity between the two groups. In the group of preoperative MR grade 3-4 the mean decrease from MR pre-TAVI to MR at 1 month post-TAVI was 0.464 (p < 0.0001) and this improvement was persistent at 6 months (p < 0.0001) and at 12 months (p < 0.0001), with partial benefit loss at 1 and 2 years. The mean difference from Left Atrial volume post-TAVI at 1 month was 16.5 ml (p < 0.0001) and this improvement was persistent at 12 months 12.12 ml (p < 0.0001). CONCLUSIONS: TAVI effectively treats the aortic valve but as a beneficial by product also ameliorates concomitant MR. The presence of moderate-to-severe MR does not increase the acute risk of failure of TAVI. In successful procedures, the MR improves immediately and persistently.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/epidemiología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
6.
Cardiovasc Revasc Med ; 15(1): 8-12, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24290659

RESUMEN

BACKGROUND/OBJECTIVES: Stent underexpansion is a risk factor for in-stent restenosis and stent thrombosis. Existing techniques to optimize stent expansion are sometimes ineffective. The aim of this study was to evaluate the effectiveness and feasibility of Excimer Laser Coronary Angioplasty (ELCA) in improving stent expansion when high-pressure non-compliant balloon inflation was ineffective. METHODS AND RESULTS: ECLA ablation was performed at high energy during contrast injection and only within the underexpanded stent. The primary endpoint of successful laser dilatation was defined as an increase of at least 1mm(2) in minimal stent cross-sectional area (MSA) on IVUS or an increase of at least 20% in minimal stent diameter (MSD) by QCA, following redilatation with the same non-compliant balloon that had been unsuccessful prior to ELCA. Secondary endpoints were cardiac death, myocardial infarction (MI) and target lesion revascularization. Between June 2009 and November 2011, 28 patients with an underexpanded stent despite high-pressure balloon inflation were included. The mean laser catheter size was 1.2±0.4 (range 0.9-2.0mm) and a mean of 62±12mJ/mm(2) at 62±21hertz were required for optimal expansion. Laser-assisted stent dilatation was successful in 27 cases (96.4%), with an improvement in MSD by QCA (1.6±0.6mm at baseline to 2.6±0.6mm post-procedure) and MSA by IVUS (3.5±1.1mm(2) to 7.1±1.9mm(2)). Periprocedural MI occurred in 7.1%, transient slow-flow in 3.6% and ST elevation in 3.6%. During follow-up, there were no MIs, there was 1 cardiac-death, and TLR occurred in 6.7%. CONCLUSIONS: The ELLEMENT study confirms the feasibility of ELCA with contrast injection to improve stent underexpansion in undilatable stented lesions.


Asunto(s)
Angioplastia de Balón Asistida por Láser/instrumentación , Estenosis Coronaria/terapia , Láseres de Excímeros , Stents , Calcificación Vascular/terapia , Anciano , Anciano de 80 o más Años , Angioplastia de Balón Asistida por Láser/efectos adversos , Angioplastia de Balón Asistida por Láser/mortalidad , Medios de Contraste , Angiografía Coronaria , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/mortalidad , Trombosis Coronaria/etiología , Estudios de Factibilidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional , Calcificación Vascular/diagnóstico , Calcificación Vascular/mortalidad
7.
Interv Med Appl Sci ; 5(1): 10-5, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24265882

RESUMEN

OBJECTIVE: To assess the efficacy and safety of laser-assisted percutaneous coronary interventions (PCI) in an unselected population. METHODS: One hundred consecutive patients, who underwent a laser assisted PCI between January 2008 and March 2012, were included in the present study. Fifty-one patients underwent laser ablation for thrombus vaporization (Group 1), 36 patients for neointima/plaque debulking (Group 2) and 13 patients for lesion compliance modification in calcified lesions (Group 3). RESULTS: The rate of in-hospital serious events was 2%. The cumulative laser success was 82%, and it was significantly higher for Group 1 and Group 2 in comparison with Group 3 (p = 0.001). Furthermore, the need for repeat revascularization was significantly higher in the Group 3 compared with the others two groups (46% vs. 8% for Group 1 and 11% for Group 2, p = 0.03). The MACE rate was 14%. There was a trend toward a higher MACE rate in the Group 3 compared with others two groups (p = 0.05). CONCLUSIONS: Laser ablation is an effective and safe tool for complex PCI. Patients underwent laser for thrombus vaporization or for neointima/plaque debulking had better immediate success and better outcome at follow-up than patients underwent laser for lesion compliance modification.

8.
Cardiovasc Ultrasound ; 11: 18, 2013 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-23731705

RESUMEN

PURPOSE: The effect of Transcatheter Aortic Valve Implantation (TAVI) on left ventricular (LV) geometry and function was compared to traditional aortic replacement (AVR) by major surgery. METHODS: 45 patients with aortic stenosis (AS) undergoing TAVI and 33 AVR were assessed by standard echo Doppler the day before and 2 months after the implantation. 2D echocardiograms were performed to measure left ventricular (LV) mass index (LVMi), relative wall thickness (RWT), ejection fraction (EF) and the ratio between transmitral E velocity and early diastolic velocity of mitral annulus (E/e' ratio). Valvular-arterial impedance (Zva) was also calculated. RESULTS: At baseline, the 2 groups were comparable for blood pressure, heart rate, body mass index mean transvalvular gradient and aortic valve area. TAVI patients were older (p<0.0001) and had greater LVMi (p<0.005) than AVR group. After 2 months, both the procedures induced a significant reduction of transvalvular gradient and Zva but the decrease of LVMi and RWT was significant greater after TAVI (both p<0.0001). E/e' ratio and EF were significantly improved after both the procedure but E/e' reduction was greater after TAVI (p<0.0001). TAVI exhibited greater percent reduction in mean transvalvular gradient (p<0.05), Zva (p<0.02), LVMi (p<0.0001), RWT (p<0.0001) and E/e' ratio (p<0.0001) than AVR patients. Reduction of E/e' ratio was positively related with reduction of RWT (r = 0.46, p<0.002) only in TAVI group, even after adjusting for age and percent reduction of Zva (r =0.43, p<0.005). CONCLUSIONS: TAVI induces a greater improvement of estimated LV filling pressure in comparison with major prosthetic surgery, due to more pronounced recovery of LV geometry, independent on age and changes of hemodynamic load.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/estadística & datos numéricos , Ecocardiografía Doppler/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/prevención & control , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Presión Sanguínea , Comorbilidad , Femenino , Humanos , Italia/epidemiología , Masculino , Pronóstico , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/epidemiología
9.
Catheter Cardiovasc Interv ; 81(5): 864-70, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22997004

RESUMEN

OBJECTIVES: We evaluated transcatheter aortic valve Implantation (TAVI) in high-risk patients with severe aortic regurgitation (AR) in native or degenerated bioprosthetic valves. BACKGROUND: TAVI has emerged as a viable treatment modality for severe aortic stenosis in inoperable or high-risk patients. The use of TAVI for treatment of severe AR has remained largely unexplored. METHODS: Eight patients (age 79.6 years ± 5.75 years) with severe AR underwent TAVI at six tertiary hospitals between April 2010 and May 2011. All patients were considered to be at prohibitive risk for surgical aortic valve replacement (SAVR).TAVI with the nitinol based Core Valve bioprosthesis (CRS) (Medtronic) was performed in all patients. RESULTS: Transfemoral access was used in all cases. Procedural success was obtained in all cases without any intraprocedural complications. There was no in hospital or 30-day mortality. There were no cases of atrioventricular blocks requiring permanent pacemaker implantation. At a mean follow up of 15.5 ± 15 months; all patients had improvement in New York Heart Association functional class. Follow up echocardiography revealed improved or stable left ventricular ejection fraction and optimal device function in all cases. CONCLUSIONS: TAVI with the CRS bioprosthesis is feasible and effective in appropriately selected cases of severe aortic regurgitation in native and bioprosthetic aortic valves.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Aleaciones , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Italia , Masculino , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
11.
Catheter Cardiovasc Interv ; 80(7): 1112-7, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-22422701

RESUMEN

OBJECTIVES: The aim of the study was to compare outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in saphenous vein graft (SVG) interventions in a case-control study with a long-term follow-up. BACKGROUND: Safety and efficacy of DES in SVG interventions are still controversial. METHODS: We performed a multicenter registry assessing clinical outcomes with DES vs. BMS. We included 311 patients (239 men, age 68 ± 8 years) who underwent percutaneous coronary interventions (PCI) of SVG lesions with DES (n = 138) or BMS (n = 173) with a 2-year follow-up. RESULTS: The two groups were similar for age, sex, main risk factors, incidence of diabetes, use of IIb/IIIa antagonists, use of aspiration devices or filters, number of stents, and total stent length. Overall, at 9 months follow-up incidence of major adverse cardiac events (MACE) and target vessel revascularization (TVR) were significantly lower in the DES group compared with the BMS group (10.9% vs. 22.0%, P = 0.014 and 8.7% vs. 19.1% in DES and BMS respectively, P = 0.015), while there was no significant difference in incidence of myocardial infarction (5.1% vs. 5.2%, P = 0.96) or death (2.2% vs. 4%, respectively, P = 0.54). However, at 24-month follow-up incidence of MACE was 29.7% in the DES group and 37.0% in BMS group (P = 0.29); incidence of TVR (23.2% vs. 28.9% P = 0.39), myocardial infarction (9.4% vs. 9.2%), death (7.2% vs. 6.9%) were also similar in the two groups. CONCLUSIONS: Although DES appear safe, our findings suggest that the early benefit of DES in SVG may rapidly wane during long-term follow-up.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/terapia , Intervención Coronaria Percutánea/instrumentación , Vena Safena/trasplante , Anciano , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Puente de Arteria Coronaria/mortalidad , Supervivencia sin Enfermedad , Femenino , Oclusión de Injerto Vascular/diagnóstico , Oclusión de Injerto Vascular/mortalidad , Humanos , Incidencia , Italia/epidemiología , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Puntaje de Propensión , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
J Cardiovasc Med (Hagerstown) ; 13(5): 334-5, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22450865

RESUMEN

Coronary aneurysm is a rare complication after coronary excimer laser angioplasty. A 45-year-old woman underwent laser angioplasty and bare metal direct stenting of the proximal segment of the left anterior descending artery (LAD); after 3 months, angiographic follow-up showed significant ostial stenosis of the LAD with a large sacciform aneurysm and diffuse intrastent restenosis.


Asunto(s)
Angioplastia por Láser/efectos adversos , Aneurisma Coronario/etiología , Estenosis Coronaria/terapia , Angioplastia por Láser/instrumentación , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/cirugía , Angiografía Coronaria , Puente de Arteria Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/cirugía , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Láseres de Excímeros/efectos adversos , Persona de Mediana Edad , Stents , Factores de Tiempo , Resultado del Tratamiento
14.
JACC Cardiovasc Interv ; 4(2): 155-64, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21349453

RESUMEN

OBJECTIVES: This study sought to evaluate the long-term angiographic and clinical outcomes after the treatment of drug-eluting stent in-stent restenosis (DES-ISR) based on the angiographic pattern of restenosis. BACKGROUND: Long-term outcomes after percutaneous treatment of DES-ISR are unclear. METHODS: This study performed a retrospective analysis of 481 consecutive de novo DES-ISR lesions (n = 392) treated percutaneously between August 2002 and July 2007. The lesions were divided based on the pattern of restenosis: focal (305; 63.4%), diffuse (120; 24.9%), and occlusive (56; 11.6%). RESULTS: The majority (65%) of patients had angina or ischemia on presentation and 13% had an acute coronary syndrome. Angiographic follow-up after treatment of DES-ISR was available in 65.5% of lesions. A second angiographic restenosis occurred in 29.1% of the focal group, 45.8% (p = 0.007) of the diffuse, and 65.6% (p < 0.0001) of the occlusive. The pattern of DES-ISR predicted the pattern of recurrence: occlusive reoccluded in 66.7%; diffuse recurred as diffuse or occlusive in 57.9%; focal as focal in 67.2%. During a median follow-up of 2.97 years (interquartile range: 2.37 to 3.89), major adverse cardiac events occurred in 32.8% of patients with no significant differences among the focal, diffuse, and occlusive groups (30.9%, 38.7%, 31.1%; p = 0.38). Diffuse restenosis was associated with a significantly higher target lesion revascularization rate compared with focal (27.1% vs. 15.8%; p = 0.008). A disparity between restenosis (65.6%) and target lesion revascularization (18.5%) rates for occlusive DES-ISR suggests that as many recurrent restenoses were occlusive, they were not retreated. CONCLUSIONS: DES-ISR identifies a high-risk cohort that is at an increased risk of events, in particular repeat revascularization, during long-term follow-up. The initial pattern of restenosis is the most important predictor of recurrent restenosis or the need for subsequent reintervention.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Síndrome Coronario Agudo/etiología , Síndrome Coronario Agudo/terapia , Anciano , Angina de Pecho/etiología , Angina de Pecho/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Distribución de Chi-Cuadrado , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Isquemia Miocárdica/etiología , Isquemia Miocárdica/terapia , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sudáfrica , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
15.
Heart Vessels ; 25(4): 275-81, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20676834

RESUMEN

Although many thrombectomy devices have been tested in ST-segment elevation acute myocardial infarction (STEMI), there are no comparative data on safety or effectiveness in thrombectomy or ST-segment resolution. This study compares manual versus nonmanual thrombectomy devices in patients undergoing primary or rescue percutaneous coronary intervention in a tertiary care center. We identified 232 consecutive patients with STEMI and time from symptom onset to emergency room contact of < or = 12 h undergoing percutaneous coronary intervention with coronary thrombectomy devices. Primary end point was ST-segment resolution of > or = 70%. Several angiographic, procedural and clinical secondary end points were also evaluated. The manual thrombectomy group included 110 patients and the nonmanual group 122 patients. Both groups were similar in their clinical characteristics. The primary end point occurred with similar frequency in patients treated with manual versus nonmanual thrombectomy (67.9% vs 60.0%, P = 0.216). No significant differences were found in the two groups with regard to procedural complications, angiographic reperfusion parameters, in-hospital major adverse cardiac events, or infarct size, whereas manual thrombectomy was associated with a better left ventricle ejection fraction at discharge. Furthermore, treatment with a manual thrombectomy device was associated with significantly shorter procedural times (69 min vs 95 min, P < 0.001) and lower procedural costs (2981 euros vs 7505 euros, P < 0.001). The use of manual thrombus-aspiration catheters appeared equivalent to nonmanual thrombectomy devices in the setting of primary or rescue percutaneous intervention in terms of clinical efficacy, and led to shorter procedures and cost savings.


Asunto(s)
Angioplastia Coronaria con Balón , Infarto del Miocardio/terapia , Trombectomía/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Distribución de Chi-Cuadrado , Angiografía Coronaria , Circulación Coronaria , Diseño de Equipo , Femenino , Hemorragia/etiología , Humanos , Italia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Infarto del Miocardio/fisiopatología , Oportunidad Relativa , Puntaje de Propensión , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Volumen Sistólico , Succión , Trombectomía/efectos adversos , Trombectomía/métodos , Trombectomía/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
16.
G Ital Cardiol (Rome) ; 11(2): 138-41, 2010 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-20408477

RESUMEN

BACKGROUND: The aim of the present study was to investigate the relationship between carotid and aortic atherosclerosis in asymptomatic subjects. METHODS: Eighty-three consecutive patients without history of cardio- and cerebrovascular disease, referred for transesophageal echocardiography, were enrolled into the study. RESULTS: Aortic plaques were found in 40 out of 83 patients, whereas carotid atherosclerosis was present in 43% of the entire study population and in 75% of patients with aortic atherosclerosis (30 out of 40 patients). At multivariate logistic analysis, the presence of carotid atherosclerosis was a predictor of aortic atheroma, independently of traditional risk factors. CONCLUSIONS: In asymptomatic patients, aortic plaque occurrence may reflect the presence of carotid plaques and an ultrasound assessment should be advised.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Adulto , Anciano , Enfermedades de la Aorta/patología , Aterosclerosis/patología , Enfermedades de las Arterias Carótidas/patología , Diagnóstico Precoz , Ecocardiografía Transesofágica , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Factores de Riesgo , Índice de Severidad de la Enfermedad , Túnica Media/diagnóstico por imagen
17.
G Ital Cardiol (Rome) ; 9(2): 126-33, 2008 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-18383775

RESUMEN

BACKGROUND: Manual thrombus aspiration seems to improve myocardial reperfusion after coronary angioplasty in patients with ST-elevation acute coronary syndrome. We sought to assess the independent variables of complete myocardial reperfusion after primary and rescue coronary angioplasty with use of the Export manual thrombus aspiration catheter. METHODS: Myocardial reperfusion were judged complete if ST-segment resolution were >70% at 60 min post-procedure ECG. Sixty-three consecutive patients undergoing primary (81%) or rescue angioplasty (19%) with use of the Export catheter were analyzed. RESULTS: Forty-three (68%) patients had a complete myocardial reperfusion and 20 (32%) patients did not. The independent predictors of failed myocardial reperfusion, at multivariate analysis, were: heart rate at hospital admission (odds ratio [OR] 1.05; 95% confidence interval [CI] 1.01-1.09; p = 0.007), time to angioplasty >3 h (OR 6.07; 95% CI 1.31-27.97; p = 0.005), left anterior descending coronary artery involvement (OR 8.8; 95% CI 2.12-36.4; p = 0.003). CONCLUSIONS: The present study shows that in the setting of primary or rescue angioplasty with use of Export manual thrombus aspiration catheter, patients with high heart rate on admission, an ischemic time >3 h and left anterior descending coronary artery involvement are at higher risk of failed myocardial reperfusion.


Asunto(s)
Angioplastia Coronaria con Balón , Cateterismo Cardíaco , Infarto del Miocardio/terapia , Reperfusión Miocárdica , Trombosis/terapia , Cateterismo Cardíaco/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia del Tratamiento
18.
Scand Cardiovasc J ; 38(2): 93-7, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15204234

RESUMEN

BACKGROUND: The ACE-D allele has been associated with cardiovascular disease. The study evaluates the relationship between the ACE-ID genotypes and diastolic function in healthy subjects after 6 years of follow-up. METHODS: Two hundred and seventy-five healthy volunteers aged 25-55 years had normal physical examination, 12-lead ECG, acceptable echocardiographic windows and echocardiogram at entry. Venous blood was drawn for DNA analysis. RESULTS: Two hundred and forty-two subjects completed 6 years of follow-up. Three genetically distinct groups were obtained: ACE-DD group (n=71, 26F/45M, mean age 48 +/- 7 years); ACE-ID (n=115, 39F/76M, mean age 40 +/- 7 years); and ACE-II (n=56, 20F/36M, mean age 47 +/- 6 years). Significant differences in E/A ratio were found between ACE-DD and ACE-ID, and ACE II (p=0.028, <0.0001, 0.0001), respectively. After 6 years, echocardiography showed a significant reduction of E/A ratio in the ACE-DD group, p=0.0001. CONCLUSION: The data suggest that ACE-DD is associated with deteriorating myocardial diastolic properties.


Asunto(s)
Diástole/genética , Hemodinámica/genética , Peptidil-Dipeptidasa A/genética , Polimorfismo Genético , Población Blanca/genética , Adulto , Factores de Edad , Alelos , Análisis de Varianza , Estudios de Cohortes , Diástole/fisiología , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Probabilidad , Estudios Prospectivos , Valores de Referencia , Medición de Riesgo , Factores Sexuales , Factores de Tiempo
19.
J Heart Lung Transplant ; 22(2): 214-7, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12581773

RESUMEN

No randomized, placebo-controlled studies have investigated interferon-alpha therapy in enterovirus-proven myocarditis. This report describes 2 patients with enterovirus-induced myocarditis (1 with associated Churg-Strauss syndrome) who at follow-up endomyocardial biopsy showed clinical and hemodynamic improvement and viral clearance (using polymerase chain reaction) after interferon-alpha therapy.


Asunto(s)
Antivirales/uso terapéutico , Infecciones por Enterovirus/tratamiento farmacológico , Interferón-alfa/uso terapéutico , Miocarditis/tratamiento farmacológico , Adulto , Anciano , Biopsia , Síndrome de Churg-Strauss/complicaciones , Humanos , Interferón alfa-2 , Masculino , Miocarditis/complicaciones , Miocarditis/virología , Miocardio/patología , Proteínas Recombinantes , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
20.
Ital Heart J Suppl ; 3(9): 952-4, 2002 Sep.
Artículo en Italiano | MEDLINE | ID: mdl-12407865

RESUMEN

We describe a case of a 54-year-old woman with a history of palpitations due to recurrent atrial fibrillation. The diagnosis of a coronary artery fistula between the right coronary artery and right atrium was made after the detection of a continuous cardiac murmur. In view of the patient symptoms and owing to the aneurysmatic dilation of the fistula, she was submitted to percutaneous closure. The anatomic features of the fistula and the closure device used demonstrate the peculiarity of the intervention. An artery-venous loop crossing the coronary fistula was created via the femoral vein and artery; the Amplatzer duct occluder was then advanced through this loop up to the fistula neck and successfully delivered. At 1-month follow-up the patient was totally asymptomatic. Cardiac auscultation revealed that the murmur was no longer detectable. Current guidelines for the treatment of coronary fistulas and on their percutaneous closure are discussed.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedad Coronaria/terapia , Fístula/terapia , Atrios Cardíacos , Fístula Vascular/terapia , Adulto , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...