Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Mater Eng Perform ; 20(4): 816-818, 2011 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-21666855

RESUMEN

Most implantable medical devices are expected to function in the body over an extended period of time. Therefore, immersion tests under simulated conditions can be useful for assessing the amount of metal ions released in situ. In this investigation, dissolved ions from as-received binary and ternary Nitinol alloys in cell culture media were periodically measured under static and dynamic conditions. Endothelial cells were grown in aliquots of culture media obtained and the effect of dissolved ions on cell proliferation and viability of endothelial cells (HUVEC) was studied by cytotoxicity assays. The concentration of metal ions in the media was measured by inductively coupled plasma mass spectrometry.

2.
J Long Term Eff Med Implants ; 19(2): 113-22, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-20666711

RESUMEN

Nitinol (an acronym for the Nickel-Titanium Naval Ordnance Laboratory) has been extensively explored as an implant material for the medical industry. The potential problem with Nitinol implant devices is the release of Ni in the human body, which has stimulated a great deal of research on surface modifications and the application of coatings. This paper presents a comprehensive review of various treatments to modify the surface of Nitinol in an effort to inhibit Ni release and to render improved biocompatibility. We discuss the important in-service properties of Nitinol, such as biocompatibility, corrosion resistance, stability, uniformity, and the nature of passivating oxides produced by passivation, electropolishing, magnetoelectropolishing, ion beam implantation, sterilization, and artificial coatings.


Asunto(s)
Aleaciones , Prótesis e Implantes , Diseño de Prótesis , Polímeros , Propiedades de Superficie
3.
J Bone Joint Surg Br ; 88(6): 712-5, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16720760

RESUMEN

The aim of this study was to assess whether a femoral component which retained the neck reduced the incidence of leg-length inequality following total hip arthroplasty. A retrospective review was undertaken of 130 consecutive primary total hip arthroplasties performed between April 1996 and April 2004 using such an implant. There were 102 suitable patients for the study. Standardised pre- and post-operative pelvic radiographs were measured by an independent investigator to the nearest millimetre. The leg-length inequality was reduced from a mean pre-operative value of -0.71 cm to a mean of 0.11 cm post-operatively. Of the 102 patients 24 (23.5%) had an equal leg-length post-operatively, and 95 (93.1%) had a leg-length inequality between -1 cm and 1 cm.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Prótesis de Cadera , Diferencia de Longitud de las Piernas/prevención & control , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Fémur/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Humanos , Diferencia de Longitud de las Piernas/diagnóstico por imagen , Diferencia de Longitud de las Piernas/etiología , Masculino , Diseño de Prótesis , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA