Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Clin Microbiol ; 51(2): 571-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23241371

RESUMEN

Hepatitis C virus (HCV) RNA viral load (VL) monitoring is a well-established diagnostic tool for the management of chronic hepatitis C patients. HCV RNA VL results are used to make treatment decisions with the goal of therapy to achieve an undetectable VL result. Therefore, a sensitive assay with high specificity in detecting and accurately quantifying HCV RNA across genotypes is critical. Additionally, a lower sample volume requirement is desirable for the laboratory and the patient. This study evaluated the performance characteristics of a second-generation real-time PCR assay, the Cobas AmpliPrep/Cobas TaqMan HCV quantitative test, version 2.0 (CAP/CTM HCV test, v2.0), designed with a novel dual-probe approach and an optimized automated extraction and amplification procedure. The new assay demonstrated a limit of detection and lower limit of quantification of 15 IU/ml across all HCV genotypes and was linear from 15 to 100,000,000 IU/ml with high accuracy (<0.2-log(10) difference) and precision (standard deviation of 0.04 to 0.22 log(10)). A specificity of 100% was demonstrated with 600 HCV-seronegative specimens without cross-reactivity or interference. Correlation to the Cobas AmpliPrep/Cobas TaqMan HCV test (version 1) was good (n = 412 genotype 1 to 6 samples, R(2) = 0.88; R(2) = 0.94 without 105 genotype 4 samples). Paired plasma and serum samples showed similar performance (n = 25, R(2) = 0.99). The sample input volume was reduced from 1 to 0.65 ml in the second version. The CAP/CTM HCV test, v2.0, demonstrated excellent performance and sensitivity across all HCV genotypes with a smaller sample volume. The new HCV RNA VL assay has performance characteristics that make it suitable for use with currently available direct-acting antiviral agents.


Asunto(s)
Hepacivirus/genética , Hepatitis C/diagnóstico , Hepatitis C/virología , Juego de Reactivos para Diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa , Carga Viral , Genotipo , Humanos , Sondas de Ácido Nucleico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
J Clin Microbiol ; 45(9): 2993-8, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17626166

RESUMEN

We evaluated the use of the BD GeneOhm MRSA real-time PCR assay (BD Diagnostics, San Diego, CA) for the detection of nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA). The initial evaluation consisted of 403 paired nasal swabs and was done using the specimen preparation provided with the kit and an in-house lysis method that was specifically developed to accommodate large-volume testing using a minimal amount of personnel time. One swab was placed in an achromopeptidase (ACP) lysis solution, and the other was first used for culture and then prepared according to the kit protocol. PCR was performed on both lysates, and results were compared to those for culture. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PCR assay were 98%, 96%, 77%, and 99.7% with the kit lysate and 98%, 95%, 75%, and 99.7% with the ACP lysate (P, not significant), respectively. The second evaluation was done after implementation of all-admission surveillance using PCR with ACP lysis and a sampling of 1,107 PCR-negative samples and 215 PCR-positive samples that were confirmed by culture. The results of this sampling showed an NPV of 99.9% and a PPV of 73.5% (prevalence, 6%), consistent with our initial findings. The BD GeneOhm MRSA assay is an accurate and rapid way to detect MRSA nasal colonization. When one is dealing with large specimen numbers, the ACP lysis method offers easier processing without negatively affecting the sensitivity or specificity of the PCR assay.


Asunto(s)
Técnicas Bacteriológicas/métodos , Resistencia a la Meticilina/genética , Reacción en Cadena de la Polimerasa/métodos , Infecciones Estafilocócicas/diagnóstico , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/aislamiento & purificación , Técnicas Bacteriológicas/economía , Portador Sano/microbiología , Humanos , Nariz/microbiología , Reacción en Cadena de la Polimerasa/economía , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/genética , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...