Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 478: 135467, 2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-39146586

RESUMEN

Formaldehyde (HCHO) is a major indoor pollutant that is extremely harmful to human health even at ppb-level. Meanwhile, ppb-level HCHO is also a potential disease marker in the exhalation of patients with respiratory diseases. Higher humidity resistance and lower practical limit of detection (pLOD) both have to be pursued for practical HCHO sensors. In this work, by assembling indium oxide (In2O3) and fluorinated dipole modified reduced graphene oxide (rGO), we prepared a high-performance room temperature HCHO sensor (In2O3 @ATQ-rGO). Excellent sensing properties toward HCHO under visible illumination have been achieved, including ultra-low pLOD of 3 ppb and high humidity-resistance. By control experiments and density functional theory calculation, it is indicated that the introduced fluorinated dipoles act as not only an "umbrella" to improve the humidity resistance of the composite, but also a "bridge" to accelerate the electron transport, improving the sensitivity of the material. The significant practicality and reliability of the obtained sensors were verified by in-situ simulation experiments using a 3 m3 test chamber with a humidity control system and by detection of the simulated lung disease patient's exhalation. This work provides an effective strategy of simultaneously achieving high humidity-resistance and low pLOD of room temperature formaldehyde sensing materials.

2.
ACS Sens ; 9(6): 3282-3289, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38864828

RESUMEN

A new type of carbonized polymer dot was prepared by the one-step hydrothermal method of triethoxylsilane (TEOS) and citric acid (CA). The sensor made from carbonized polymer dots (CPDs) showed superior gas sensing performance toward ammonia at room temperature. The Si, O-codoped CPDs exhibited superior ammonia sensing performance at room temperature, including a low practical limit of detection (pLOD) of 1 ppm (Ra/Rg: 1.10, 1 ppm), short response/recovery time (30/36 s, 1 ppm), high humidity resistance (less than 5% undulation when changing relative humidity to 80 from 30%), high stability (less than 5% initial response undulation after 120 days), reliable repeatability, and high selectivity against other interferential gases. The gas sensing mechanism was investigated through control experiments and in situ FTIR, indicating that Si, O-codoping essentially improves the electron transfer capability of CPDs and synergistically dominates the superior ammonia sensing properties of the CPDs. This work presents a facile strategy for constructing novel high-performance, single-component carbonized polymer dots for gas sensing.


Asunto(s)
Amoníaco , Polímeros , Temperatura , Amoníaco/análisis , Polímeros/química , Carbono/química , Gases/análisis , Gases/química , Silicio/química , Límite de Detección , Puntos Cuánticos/química , Oxígeno/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA