Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biologicals ; 85: 101751, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38387156

RESUMEN

Viral clearance steps are routinely included in monoclonal antibody purification processes to safeguard product from potential virus contamination. These steps are often experimentally studied using product-specific feeds and parameters for each project to demonstrate viral clearance capability. However, published evidence suggests that viral clearance capability of many of these steps are not significantly impacted by variations in feed material or process parameter within commonly used ranges. The current investigation confirms robust retrovirus inactivation by low pH treatment and parvovirus removal by second-generation virus filters, independent to individual antibody molecules. Our results also reveal robust retrovirus removal by flowthrough anion exchange chromatography, inside the limits of protein load and host cell protein content. The cumulative viral clearance capability from these steps leads to an excess clearance safety factor of 10,000-fold for endogenous retrovirus-like particles. These results further justify the use of prior knowledge-based modular viral clearance estimation as opposed to repetitive experimentation.


Asunto(s)
Retrovirus Endógenos , Parvovirus , Virus , Anticuerpos Monoclonales , Filtración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...