1.
J Antimicrob Chemother ; 44(5): 669-74, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10552984

RESUMEN

A subcutaneous catheter model in the rat was developed that allowed the study of prevention and treatment strategies for foreign body infection. In contrast to earlier models, the foreign body was inoculated with a low inoculum of Staphylococcus epidermidis just before implantation, thus mimicking intraoperative contamination with skin flora. Reproducible infection of all catheters followed if no prophylaxis was given. However, foreign body infection could be prevented or treated with antibiotics such as teicoplanin, which was marginally effective, and rifampicin, which proved very effective.


Asunto(s)
Catéteres de Permanencia/efectos adversos , Modelos Animales de Enfermedad , Cuerpos Extraños , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/prevención & control , Animales , Antibacterianos/uso terapéutico , Profilaxis Antibiótica , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/prevención & control , Ratas , Ratas Endogámicas F344 , Ratas Wistar , Rifampin/uso terapéutico , Staphylococcus epidermidis/efectos de los fármacos , Teicoplanina/uso terapéutico