Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiovasc Imaging ; 21(2-3): 239-47; discussion 249-51, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16015435

RESUMEN

PURPOSE: A dynamic cardiac phantom was used as a reference to compare volumes measured with gated SPECT and 4D echocardiography. MATERIAL AND METHODS: Gated SPECT data were acquired with a standard single-head gamma camera, and the volume reconstructions were carried out using the Mirage software by Segami. 4D echocardiography used a new prototype of rotating scan head to acquire ultrasound images during a cardiac cycle, used to reconstruct the volume deformations as a function of time. End-diastolic volume, end-systolic volume, and ejection fraction were measured using both gated SPECT and 4D echocardiography. RESULTS: The results obtained showed a good correlation between volumes measured with the two modalities, but a slight overestimation of volumes with gated SPECT. The influence of filtering and pixel size parameters on the measured volumes was quantified for gated SPECT, in order to correct the overestimation. CONCLUSION: The agreement between gated SPECT (after correction) and 4D echocardiography confirmed the relevance of the comparisons. This study was an initial step before conducting clinical trials to compare exhaustively left ventricular volumes obtained with the two modalities.


Asunto(s)
Volumen Cardíaco/fisiología , Ecocardiografía Tetradimensional , Fantasmas de Imagen , Tomografía Computarizada de Emisión de Fotón Único , Gasto Cardíaco/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Función Ventricular Izquierda/fisiología
2.
Eur J Nucl Med Mol Imaging ; 31(2): 222-8, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15129704

RESUMEN

A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit into the Data Spectrum anthropomorphic torso phantom. Flexible silicone membranes form the inner and outer walls of the simulated left ventricle. Simulated LV volumes can be varied within the range 45-200 ml. The LV volume curve has a smooth and realistic clinical shape that is produced by a specially shaped cam connected to a piston. A fixed 70-ml stroke volume is applied for EF measurements. An ECG signal is produced at maximum LV filling by a controller unit connected to the pump. This gated cardiac phantom will be referred to as the Amsterdam 3-D gated cardiac phantom, or, in short, the AGATE cardiac phantom. SPET data were acquired with a triple-head SPET system. Data were reconstructed using filtered back-projection following pre-filtering and further processed with the Quantitative Gated SPECT (QGS) software to determine LV volume and EF values. Ungated studies were performed to measure LV volumes ranging from 45 ml to 200 ml. The QGS-determined LV volumes were systematically underestimated. For different LV combinations, the stroke volumes measured were consistent at 60-61 ml for 8-frame studies and 63-65 ml for 16-frame studies. QGS-determined EF values were slightly overestimated between 1.25% EF units for 8-frame studies and 3.25% EF units for 16-frame studies. In conclusion, the AGATE cardiac phantom offers possibilities for quality control, testing and validation of the whole gated cardiac SPET sequence, and testing of different acquisition and processing parameters and software.


Asunto(s)
Análisis de Falla de Equipo , Imagen de Acumulación Sanguínea de Compuerta/instrumentación , Corazón/diagnóstico por imagen , Imagenología Tridimensional/instrumentación , Fantasmas de Imagen , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Diseño de Equipo , Imagen de Acumulación Sanguínea de Compuerta/métodos , Imagen de Acumulación Sanguínea de Compuerta/normas , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Países Bajos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...